10. Fault coding
The following fault codes are blinking in the LCD-display:
Code
LCD
Meaning
possible cause of fault
SA
KT
longfresh air sensor defective
sensor short circuit, sensor
disconnection/interruption
sb
KT
longfresh evaporator sensor
sensor short circuit, sensor
defective
disconnection/interruption
sc
KT
refrigerator air sensor defective
sensor short circuit, sensor
disconnection/interruption
sd
KT
refrigerator evaporator sensor
sensor short circuit, sensor
defective
disconnection/interruption
SF
GT
freezer air sensor defective
sensor short circuit, sensor
disconnection/interruption
FO
KT
EEPROM read error
EEPROM not or incorrectly connected
F1
KT
U-evaporator not cooled in
sensors crossed, longfresh fan not
pre-set time period
running, cooling system in longfresh
compartment blocked
F2
KT
air in longfresh compartment
sensors crossed, longfresh fan
not cooled in pre-set time
not running, magnetic valve not
period
switched
F3
KT
U-evaporator too warm
sensors crossed, appliance was not
compared to longfresh
sufficiently warm prior to test
air temperature
F4
KT
U-evaporator too warm
sensors crossed, appliance was not
compared to refrigerator
sufficiently warm prior to test, magnetic
air temperature
valve not switched
F5
KT
U-evaporator too warm
sensors crossed, appliance was not
compared to refrigeration
sufficiently warm prior to test,
evaporator temp.
magnetic valve not switched
F6
KT
longfresh-air temperature too
sensors crossed, appliance was not
warm compared to refrigerator
sufficiently warm prior to test,
air temperature
magnetic valve not switched