Electrolux S105GE Скачать руководство пользователя страница 4

Check that the door gasket seals all around when the
door is closed and that the door moves freely

Move cover plate from one handle mould to the otherone

DOOR PANEL

The door panel can easily be mounted or changed. The
dimensions of the panel must be:

Height

. . . . . . . . . . . . . . . . . . . . . . . . . 722 mm

Width

. . . . . . . . . . . . . . . . . . . . . . . . . 504 mm

Thickness. . . . . . . . . . . . . . . . . . . . max 3.8 mm

Remove the door, see REPOSITIONING THE HINGES.

Remove the lower trim moulding and then withdraw the
panel by sliding it downwards.

Fit the new panel in place and slide it up as far as possi-
ble.

Fit the trim moulding back in place.

INSTALLATION

The room should have a capacity (length x width x height)
of at least 20 m

3

and have a window (which can be opened)

or a door to the outside.

It is important that the refrigerator is not subject to radiation
of heat from a stove etc.

For best performance also at high ambient temperatures
there must be a free air circulation over the cooling unit at
the rear of the refrigerator.

The refrigerator is designed for a free-standing installation
and the clearance to side walls etc., should be at least 5 cm
(2'').

LP GAS CONNECTION

The refrigerator is designed for operation on LP gas, the
pressure of which must be 28 mbar for Butane and 37 mbar
for Propane. Check that this is stated on the data plate.

The refrigerator is not designed for operation on town gas or
natural gas.

The gas installation should only be carried out by an autho-
rized gas fitter.

The gas supply pipe should be connected to the gas inlet
pipe on the right hand side of the gas control valve by
means of a suitable threaded coupling.

In making the connection to the refrigerator, a union gas
cock of an approved bottled-gas type must be incorporated
in the supply line in a position which is readily accessible to
the user. For eventual servicing purposes, the union should
be on the outlet side of the cock and the pipework should
be positioned so as not to prevent the refrigerator from
being readily withdrawn.

ELECTRICAL CONNECTION

The electrical installation must be carried out in a proper
and durable manner, taking into account all relevant regu-
lations and codes of practice. For mains voltage operation,
it is important that the circuit to and in the caravan is effec-
tively earthed.

ALL MAINS VOLTAGE WIRING IN THE CARAVAN MUST
BE INSTALLED IN ACCORDANCE WITH CURRENT
I.E.E. REGULATIONS INCLUDING THE USE OF AN
OUTLET AND COUPLER TO BS4343/- CEE17.

For connection to a 230 V electricity supply, the refrigerator
has a 3-core mains lead which is intended for connection to
a properly earthed plug and socket outlet. The socket outlet
should be fitted in the caravan in a position readily accessi-
ble to the user, within reach of the mains lead. In the United
Kingdom, the plug and socket outlet should be of the non-
reversible type.

IMPORTANT: The wires in the mains lead of this appliance
are coloured in accordance with the following code:

GREEN-AND-YELLOW = EARTH

BLUE = NEUTRAL

BROWN = LIVE

As the colours of the wires may not correspond with the
coloured markings identifying the terminals in your plug, in
the United Kingdom, proceed as follows:

The wire which is coloured GREEN-AND-YELLOW must be
connected to the terminal in the plug which is marked with
the letter E or by the earth symbol

, or coloured green

or green-yellow.

The wire which is coloured BLUE must be connected to the
terminal which is marked with the letter N or coloured black.

The wire which is coloured BROWN must be connected to
the terminal which is marked with the letter L or coloured
red.

WARNING - THIS APPLIANCE MUST BE EARTHED.

In the United Kingdom, the plug or circuit to the refrige-rator
must be fitted with a fuse not greater than 5 amps. If a 13
amp.(B.S.1363) fused plug is used, it should be fitted with a
3 amp. fuse. In other countries, the fuse rating will depend
upon the voltage and local practice.

Plug the 230 V refrigerator power cord into an easily acces-
sible wall socket.

The notations in the wiring diagramme (fig. 2) are:

G. Electric thermostat

H. Heating element, 230 V

I. Switch for 230 V operation

CAUTION! CHECK THAT THE GAS SUPPLIED TO THE

REFRIGERATOR IS AT THE CORRECT PRESSURE.

SEE THE REDUCING VALVE ON THE LP GAS CON-

TAINER.

Electrical leads must be routed and secured so that

they cannot come into contact with hot or sharp parts

of the refrigerator.

8

Содержание S105GE

Страница 1: ...nded for different sources of energy S105 G LP Gas S105 GE LP Gas and Electric DATA PLATE Check the data plate inside the refrigerator to ensure that you have received the right model The right gas pressure is 30 mbar The right voltage is 230 volts The data plate contains e g the following details Model designation Product number Serial number Since these details will be needed if you have to get ...

Страница 2: ...ke a few hours to become cold On 230 V operation the refrigerator is controlled by a ther mostat and the thermostat knob B should be set at 3 5 If a lower colder temperature is desired set the thermostat to a higher figure On LP gas operation the refrigerator temperature is regu lated by the gas thermostat E which should be set at 3 4 If a lower colder temperature is desired set the thermostat to ...

Страница 3: ...in table top obstructed 2 The evaporator is frosted up 3 The temperature control setting is incorrect 4 The gas pressure is incorrect check the pressure regu lator at the gas container 5 The ambient temperature is too high 6 To much food is loaded at one time 7 The door is not properly closed or the magnetic door seal is defective 8 More than one source of energy is used at one time If the refrige...

Страница 4: ...ing into account all relevant regu lations and codes of practice For mains voltage operation it is important that the circuit to and in the caravan is effec tively earthed ALL MAINS VOLTAGE WIRING IN THE CARAVAN MUST BE INSTALLED IN ACCORDANCE WITH CURRENT I E E REGULATIONS INCLUDING THE USE OF AN OUTLET AND COUPLER TO BS4343 CEE17 For connection to a 230 V electricity supply the refrigerator has ...