manualshive.com logo in svg
background image

The supply pipe should preferably be of copper. If any

other material is used, it must be of a type approved for

use with continuously operating bottled- gas appliances,

and have threaded compression connections throughout.

PUSH-ON CONNECTIONS MUST NOT BE USED

(We

do not approve the use of "rubber" type flexible tubing for

connecting permanently operating appliances of this type

in the United Kingdom). All connectors etc. should be of a

type specifically designed for the type and diameter of the

connection pipe used, and screwed joints should be sea-

led with a joining compound approved for use with bottled

gas.

The gas supply pipe should be connected to the gas inlet

pipe on the right hand side of the gas control valve by

means of a suitable threaded compression coupling.
In making the connection to the refrigerator, a gas cock of

an approved type for use LPG must be incorporated in

the supply line in a position which is readily accessible to

the user. For eventual servicing purposes, the union

should be on the outlet side of the cock and the pipework

should be positioned so as not to prevent the

refrigerator from being readily withdrawn.

ELECTRICAL CONNECTION

The electrical installation must be carried out in a proper

and durable manner, taking into account all relevant regu-

lations and codes of practice. For mains voltage operati-

on, it is important that the circuit to and in the caravan is

effectively earthed. 

ALL MAINS VOLTAGE WIRING IN THE CARAVAN

MUST BE INSTALLED IN ACCORDANCE WITH CUR-

RENT I.E.E. REGULATIONS INCLUDING THE USE OF

AN OUTLET AND COUPLER TO BS4343/-CEE17.

For connection to a 230 V electricity supply, the refrigera-

tor has a 3-core mains lead which is intended for connec-

tion to a properly earthed plug and socket outlet or fused

spur.

IMPORTANT:

The wires in the mains lead of this applian-

ce are coloured in accordance with the following code:

GREEN-AND-YELLOW = EARTH 
BLUE = NEUTRAL
BROWN = LIVE
As the colours of the wires may not correspond with the

coloured markings identifying the terminals in your plug,

in the United Kingdom, proceed as follows:

The wire which is coloured 

GREEN-AND-YELLOW

must

be connected to the terminal in the plug which is marked

with the letter E or by the earth symbolor

coloured green or green-and-yellow.
The wire which is coloured 

BLUE

must be connected to

the terminal which is marked with the letter N or coloured

black.

The wire which is coloured 

BROWN

must be connected

to the terminal which is marked with the letter L or colou-

red red.

WARNING! THIS APPLIANCE MUST BE

EARTHED!

In the United Kingdom, the plug or circuit to the refrigera-

tor must be fitted with a fuse not greater than 5 amps. If a

13 amp.(B.S.1363) fused plug is used, it should be fitted

with a 3 amp. fuse. In other countries, the fuse rating will

depend upon the voltage and local practice.

230 V Supplies

Check that the voltage stated on the data plate is the

same as the mains voltage in use (230 V).

Electrical leads must be routed and secured

so that they cannot come into contact with hot

or sharp parts of the refrigerator.

12 V Supplies

Connect the refrigerator to the vehicle battery by a direct

cable. To avoid a voltage drop, the cross sectional area of

the connecting cable between battery and refrigerator

must be at least 2.5 mm

2

if the distance is less than 9

meters, and at least 4 mm

2

if the distance is more than 9

meters.
To ensure satisfactory operation, the positive lead must

be fitted with a fuse rated at max. 16 A.
To prevent the refrigerator from draining the battery, make

sure that the current supplied to the caravan is cut off

when the vehicle engine is not running, for example by fit-

ting an ignition control relay.
Diagramme for the mains installation: fig. 9

Diagramme for the 12 V installation:

fig. 10 

(RM 4200/10)

The notations in the wiring diagramme are:

A. Electronic igniter/reigniter 
B. Electrode (at burner) 
C. 12 V heating element 
D. Switch for 12 V operation 
E. Switch for reigniter (gas op.) 
F. Electric thermostat 
G. Heating element, 230 V 
H. Switch for 230 V operation 
J. Terminal block 
L. Terminal block

12 V supply of reigniter (RM 4201/11)

Fig.12 /13 shows the wiring diagramme of the refrigerator

as delivered. The 12 V supply enters at (L). The reigniter

(A) is fed via two wires (1) and (2) at terminal block (L)

(RM 4211).
It is advisable to feed the reigniter and the lighting from a

separate 12 V source. To do this: remove the wires (1)

and (2) and connect the supply as is shown in fig. 11. 
The reigniter should not be connected directly to a battery

charger but only over a battery.

Содержание RM 4200

Страница 1: ...0 Rm 4211 Typ C40 110 821 2648 02 T B 08 00 CARAVAN Deutsch Seite 1 Svenska sida 31 English page 7 Dansk side 37 Français page 13 Norsk side 43 Italiano pagina 19 Nederlands pag 49 Español pagina 25 Suomi sivu 55 Português cara 61 ...

Страница 2: ...elivered DATA PLATE Check the data plate inside the refrigerator to ensure that you have received the right model The right voltage is 230 volts The data plate contains e g the following details Model designation Product number Serial number Since these details will be needed if you have to contact service personnel it is a good idea to make a note of them here CONTENTS OPERATING INSTRUCTIONS 8 CO...

Страница 3: ...ther 10 to 15 seconds to active the flame failure device then release it If you have Model RM 4200 10 proceed as follows 3 Turn the gas control D nto position MAX 4 Depress the knob D of the flame failure device and hold it down while depressing the piezoelectric igniter button F several times in quick succession 6 Keep the D buttom pressed for a further 10 to 15 seconds then release it 5 Check th...

Страница 4: ...ar of the refrigerator where it evapora tes Defrost water in the freezer compartment should be mopped up with a cloth When the ice has melted wipe the refrigerator dry and restart it Place the food items back inside but wait until the refrigerator is cold before making ice cubes CLEANING THE REFRIGERATOR Clean the inside of the refrigerator regularly to keep it fresh and hygienic Soak a cloth in a...

Страница 5: ...ctions It is also embraced by a European guarantee as descri bed in the brochure supplied with the refrigerator Service and spare sparts are obtainable from your dealer or Electrolux consult the telephone directory TECHNICAL DATA RM 42XX Overall dimensions refrigerator Height 618 mm Width 486 mm Depth incl cooling unit without door 435 mm with door 474 mm Build in dimensions Height 620 mm Width 49...

Страница 6: ...ower opening and warm air is discharged through the upper one Locate the lower opening immediately above the floor of the recess and the upper one as high as possible above the condenser C of the refrigeration unit at least as shown in fig 6b but preferably as shown in fig 6a Ventilation grilles Fig 2 The openings in the caravan wall must be fitted with the Electrolux ventilation systems Fitting t...

Страница 7: ...l in the plug which is marked with the letter E or by the earth symbolor coloured green or green and yellow The wire which is coloured BLUE must be connected to the terminal which is marked with the letter N or coloured black The wire which is coloured BROWN must be connected to the terminal which is marked with the letter L or colou red red WARNING THIS APPLIANCE MUST BE EARTHED In the United Kin...

Страница 8: ......

Страница 9: ......

Страница 10: ......

Отзывы: