18
Technical Data
Electrical Connection
The oven is designed to be connected to 230-240V (50Hz)
electricity supply.
The oven has an easily accessible terminal block which
is marked as follows:
Letter L
-
Live terminal
Letter N
-
Neutral terminal
or E
-
Earth terminal
THIS OVEN MUST BE EARTHED
The cable used to connect the oven to the electrical
supply must comply to the specifications given below.
It is necessary that you install a double pole switch
between the oven and the electricity supply (mains), with
a minimum gap of 3mm between the switch contacts and
of a type suitable for the required load in compliance with
the current rules.
The switch must not break the yellow and green earth
cable at any point.
Important
After installation and connecting, the cable must be
placed so that it cannot at any point reach a temperature
of more than 60°C above the ambient temperature.
Before the oven is connected, check that the main fuse
and the domestic installation can support the load; and
that the power supply is properly earthed.
The manufacturer disclaims any responsibility should
these safety measures not be carried out.
Connection
Min. size
Cable / flex Fuse
via
Cable/flex
type
13 A socket 2.5 mm
2
3 core
13 A
outlet
butyl
min.
13 A
insulated
spur box
Cooker
2.5 mm
2
PVC/PVC
Control
twin and
20 A
Circuit
earth
For Uk use only
For Europe use only
Min. size Cable/flex
Cable / flex type
Fuse
1.5 mm
2
H05 RR-F
13 A
Heating elements rating
Circular heating element
2.08 kW
Inner Grill element
1.82 kW
Double Grill element
2.66 kW
Oven Light
15 W
Cooling Fan
25 W
Convection Fan
30 W
Total Rating
2.70 kW
Dimensions of recess
Height
580 mm.
Width
560-570 mm.
Depth
550 mm.
Dimensions of the oven cavity
Height
320 mm.
Width
420 mm.
Depth
390 mm.
Oven capacity
53.2 litres