Electrical Information:
1. Each unit must be plugged into its own dedicated 115 Volt, 60 Hz., AC
circuit.
2. The power cord of each unit is equipped with a three-prong grounding plug
for protection against shock hazards. It must be plugged directly into a
properly grounded three-prong receptacle, protected with a 15 amp time
delay fuse or circuit breaker.
3.
Do Not
connect units to a Ground Fault Circuit Interrupter (GFCI) circuit.
Location:
1. The units must be installed on a floor that is level and strong enough to
support a fully loaded refrigerator and freezer.
2. Consider water supply availability for models equipped with an automatic ice
maker.
Clearances:
1. Allow the following clearances for ease of installation, proper air circulation,
plumbing and electrical connections.
•
Sides -------------- 3/8”
•
Top & Back ------ 1”
•
Between units ---------- 3/16”
2.
Do Not
block toe grille on the lower front of the units. Sufficient air
circulation is essential for the proper operation of the units.
Wood Base Removal:
1. Remove two leveling legs provided in literature bag. While unit is lying on its
back, remove four 3/8” hex crating bolts from wood base. Remove and
discard wood base.
2. Install both leveling legs in rear of unit and loosen front leveling legs if
necessary.
See Fig. A