background image

SERVICE MANUAL

© AEG Hausgeräte GmbH

Muggenhofer Straße 135
D-90429 Nürnberg
Germany

Fax +49 (0)911 323 1420

TSE - N
Ausgabe:

11.98

Edition:

11.98

Publ.-Nr.:
599 50 69 24
685

Dishwasher

Easytronic Dishwashers

with Flow Heater -

Fully Integrated,

Integrated, Built Under,

Freestanding

EN

DISHWASHER

Содержание OKO-FAVORIT 3270 Vi

Страница 1: ...nhofer Straße 135 D 90429 Nürnberg Germany Fax 49 0 911 323 1420 TSE N Ausgabe 11 98 Edition 11 98 Publ Nr 599 50 69 24 685 Dishwasher Easytronic Dishwashers with Flow Heater Fully Integrated Integrated Built Under Freestanding EN DISHWASHER ...

Страница 2: ...Dishwasher Height 85 cm Width 60 cm Depth 60 cm Height with worktop removed 82 cm Feet adjustment 1 cm Dimensions Build in dimensions for Fully Integrated Dishwashers ÖKO FAVORIT 6270 5270 3270 Vi Build in dimensions for Integrated Dishwashers ÖKO FAVORIT 8081 i 6060 i 5060 i 5050 i Appliances with height adjustable feet Plinth height for appliances 820 mm high 100 175 mm Plinth height for applian...

Страница 3: ...45 dB ÖKO FAVORIT 5270 U 14 l 1 05 kWh 16 l 1 25 kWh 47 dB ÖKO FAVORIT 6280 i 13 l 0 95 kWh 15 l 1 15 kWh 43 dB ÖKO FAVORIT 5280 i 13 l 0 95 kWh 15 l 1 15 kWh 45 dB ÖKO FAVORIT 5270 i 14 l 1 05 kWh 16 l 1 25 kWh 47 dB ÖKO FAVORIT 4270 i 14 l 1 05 kWh 16 l 1 25 kWh 47 dB ÖKO FAVORIT 6270 vi 13 l 1 05 kWh 15 l 1 25 kWh 43 dB ÖKO FAVORIT 5270 vi 14 l 1 05 kWh 16 l 1 25 kWh 47 dB ÖKO FAVORIT 3270 vi 1...

Страница 4: ...witch controls the water level Without water contact 11 12 is closed fN Switch point with level 65 mm Ws Reset point with level 45 mm Ws fS Switch point with safety level 114 mm Ws Reset point 90 mm Ws The pressure switch is not adjustable Flow Heater The flow heater heats the water to the required temperature During the wash cycle water is contantly passing through the flow heater Power output 21...

Страница 5: ...tacho generator is used for speed control There are three speeds for rinsing 1600 1 min 2000 1 min 2800 1 min Power output 50 W Drain Pump The drain pump is driven by a synchronous motor Power output 30 W Pump rate 15 l min NTC Temperature Sensor Technical Data NTC Temperaturfühler Temperature sensor NTC resistor Temperatur Widerstand 20 C 6032 Ω temperature resistor 25 C 4829 Ω nur bei vollelektr...

Страница 6: ...t operation adds the detergent and the second the rinse aid If the door is opened the latching bar is reset to the detergent dosage position Input Module The programs are selected via the input module which is mounted in the door All components are connected to this module Output Module Depending on models displays are integrated into the output module o salt o rinse aid o water o filter o display...

Страница 7: ...me data Drying Fan The drying fan sucks the humid air from the tub and mixes it with dry air which is drawn up from in between the door panels 1 and blows it out through a vent situated below the door handle 2 During the wash cycle the fan intake vent on the inside of the door is closed by a thermoelectric valve 3 Servo Door Lock Fully integrated dishwashers have a servo door lock Once the program...

Страница 8: ...y resin balls The resins exchange the hardness constituents calcium and magnesium for sodium ions When all the sodium ions are used up it is necessary to regenerate the softener This is done by flushing a brine solution through the softener Afterwards the softener is washed out with fresh water and is now fully effective Depending on the water hardness regeneration is only necessary after several ...

Страница 9: ...ilt Under Freestanding 292 1372 8 Detergent dispenser 1 Drying fan 2 Electronic 1 Thermal sensor 2 Drain pump 3 Pressure switch 4 Flow heater 1 Terminal board 2 Inlet valve 3 292 1372 08 1 To remove side panel 1 Remove fixing screws 2 Pull the panel away from the rear and gently out of the front trim Technical Data 1 2 3 4 2 1 2 3 ...

Страница 10: ...m the softener Removing the softener unit 1 remove the securing nut located under the salt cap 2 press softener 1 down and remove it through the front from the base area 3 CAUTION if accessible release reed switch Removing the base 1 remove side panels rear panel and plinth panel 2 gently release base fixing clips with a screwdriver figure 3 take off base carefully and release circulation pump ele...

Страница 11: ...Inlet valve 2 Air break 3 Regeneration water dosage 4 Overflow safety level 5 Safety overflow 6 Inlet to sump from regeneration dosage chamber 7 Regeneration dosage chamber 8 Softener 9 Salt container 10 Non return valve salt container 11 Regeneration valve 12 Safety inlet hose 13 Base tray 14 Float switch 15 Pressure switch 16 Filter 17 Circulation pump 18 Flow heater 19 Drain pump 20 Non return ...

Страница 12: ...ated in the base of the dishwasher The safety outer hose 12 is connected to the regeneration chamber If the inner hose should burst the water passes into the regeneration chamber and over the safety overflow 5 and into the base tray activating the float switch which energises the drain pump This drains the dishwasher preventing water damage 2 Leakage Protection The anti flood switch in the base tr...

Страница 13: ...a 1 Inlet valve 2 Air break 3 Regeneration water dosage 4 Overflow safety level 5 Safety overflow 6 Inlet to sump from regeneration dosage chamber 7 Regeneration dosage chamber 8 Softener 9 Salt container 10 Non return valve salt container 11 Regeneration valve 12 Safety inlet hose 13 Base tray 14 Float switch 15 Pressure switch 16 Filter 17 Circulation pump 18 Flow heater 19 Drain pump 20 Non ret...

Страница 14: ...tainer 10 Non return valve salt container 11 Regeneration valve 12 Safety inlet hose 13 Base tray 14 Float switch 15 Pressure switch 16 Filter 17 Circulation pump 18 Flow heater 19 Drain pump 20 Non return valve 21 Spray arms 22 Roof mounted shower 23 Tub vent 24 Sump assembly Water Inlet The water flows into the regeneration dosage chamber 7 via inlet valve 1 over air break 2 into regeneration do...

Страница 15: ...o level maximum time 60 sec Circulation The circulation pump 17 pumps the water into the roof mounted shower 22 and both spray arms 21 simultaneously The filters 16 filter the water and supply it to the circulation pump Pulsed wash action After the filling steps the circulation pump runs at two speeds 4 seconds with 1600 min 1 0 8 seconds with 2800 min 1 This new process increases the spray pressu...

Страница 16: ...th Flow Heater Fully Integrated Integrated Built Under Freestanding 292 1372 15 Technical Data speed in 1 min 60 sec per 0 8 sec per 4 sec time in sec time in sec time in sec water in l dynamic filling temporal filling statical filling PRE FILLING valve on off filling refilling possible ...

Страница 17: ...f sufficiently There is a non return valve 20 at the inlet connection to the drain pump 19 This valve prevents the water running back from the drain hose into the dishwasher 1 Inlet valve 2 Air break 3 Regeneration water dosage 4 Overflow safety level 5 Safety overflow 6 Inlet to sump from regeneration dosage chamber 7 Regeneration dosage chamber 8 Softener 9 Salt container 10 Non return valve sal...

Страница 18: ...f the salt container there is an opening with a small filter from here the brine solution passes through a non return valve 10 and enters the softener 8 where the resins are regenerated The softener has 10 settings and can be adjusted to suit the degree of water hardness Stufe Wasserhärte Restwasserhärte Salz Bedarfsabhängiges water hardness residual water hardness Salt Regenerieren nach d F d F D...

Страница 19: ...e 2 Air break 3 Regeneration water dosage 4 Overflow safety level 5 Safety overflow 6 Inlet to sump from regeneration dosage chamber 7 Regeneration dosage chamber 8 Softener 9 Salt container 10 Non return valve salt container 11 Regeneration valve 12 Safety inlet hose 13 Base tray 14 Float switch 15 Pressure switch 16 Filter 17 Circulation pump 18 Flow heater 19 Drain pump 20 Non return valve 21 S...

Страница 20: ... pause 5 sec 5 filling to switch point level 6 pumping and filling 5 sec 7 pumping 5 sec 8 filling to static level or 15 sec 9 pumping to reset point level 10 pumping 30 sec Program Outline 6 program dishwasher e g FAVORIT 6280 i or FAVORIT 6270 vi Intensive 70 C Normal 65 C Normal BIO 65 C Economy BIO 50 C Quick 40 C Pre Rinse Technical Data on off intensive 70 normal 65 normal BIO 50 economy BIO...

Страница 21: ...O 50 C Quick 50 C Pre Rinse 4 Programme FAVORIT 4270 i Intensive 65 C Normal BIO 50 C Quick 50 C Pre Rinse 3 Programmge FAVORIT 3270 vi Normal 65 C BIO 50 C Quick 50 C Technical Data on off intensive 70 normal 65 normal BIO 50 quick 40 Pre Rinse washing rinsing washing up end salt washing up liquid turbo drying drying pre rinse washing rinsing washing up end salt washing up liquid drying pre rinse...

Страница 22: ...ata Pre rinse Extra Intensive 65 Intensive 70 Normal 65 Normal BIO 50 Economy BIO 50 Quick 50 Quick 40 Fuzzy empty half or full no yes yes yes yes yes no no Tub rinse ä ä ä ä ä ä ä ä Pre rinse cold ä Pre rinse warm ä ä Washing ä ä ä ä ä ä ä Intermediate rinse ä ä ä ä ä ä ä 2 Intermediate rinse ä ä Final rinse ä ä ä ä ä ä ä Drying ä ä ä ä ä ä ä is not performed ä is performed ä is performed only pa...

Страница 23: ...9 HV 83 N H H1 GSP TECHNIK AEGHB 137201GB P65 Easytronic Dishwashers with Flow Heater Fully Integrated Integrated Built Under Freestanding 292 1372 22 Technical Data Short Outline of Service and Maintenance Functions ...

Страница 24: ...Dishwasher 04 99 HV 83 N H H1 GSP TECHNIK AEGHB 137201GB P65 Easytronic Dishwashers with Flow Heater Fully Integrated Integrated Built Under Freestanding 292 1372 23 Technical Data ...

Страница 25: ...Dishwasher 04 99 HV 83 N H H1 GSP TECHNIK AEGHB 137201GB P65 Easytronic Dishwashers with Flow Heater Fully Integrated Integrated Built Under Freestanding 292 1372 24 Technical Data ...

Страница 26: ...duration of 5 seconds in the sequence listed blelow When the last test 7 has been performed the test sequence is then repeated but will automatically be cancelled after a maximum 2 minute duration or when the appliance is turned off 1 Inlet Valve 2 regeneration valve 3 circulation pump operates in pre series with 1000 U min 4 rotarty slide 5 drain pump 6 fan and flap turbo drying 7 dosage combinat...

Страница 27: ...g 4 pole plug 4 pole plug 4 pole plug to the input module NTC Temperaturfühler Temperature sensor NTC resistor Temperatur Widerstand 20 C 6032 Ω temperature resistor 25 C 4829 Ω nur bei vollelektron 30 C 3891 Ω Geschirrspüler 40 C 2573 Ω only for fully electronic dishwasher 50 C 1741 Ω 55 C 1444 Ω 60 C 1204 Ω 65 C 1009 Ω 70 C 849 Ω 7 pole plug pin resistor Attention The mains voltage is with the 7...

Страница 28: ...e input module Carry out all resistance measurements with the connecting plug removed NTC Temperaturfühler Temperature sensor NTC resistor Temperatur Widerstand 20 C 6032 Ω temperature resistor 25 C 4829 Ω nur bei vollelektron 30 C 3891 Ω Geschirrspüler 40 C 2573 Ω only for fully electronic dishw asher 50 C 1741 Ω 55 C 1444 Ω 60 C 1204 Ω 65 C 1009 Ω 70 C 849 Ω 7 pole plug Pin Widerstand Attention ...

Отзывы: