![background image](http://html.mh-extra.com/html/electrolux/lrc9me38w4/lrc9me38w4_user-manual_2383726037.webp)
Error type
Possible cause
Solution
E08
Power supply to the
device has dropped to
below 170 V.
The voltage needs to be increased back
to required levels.
E10
Fridge compartment is
not cold enough.
Set a colder temperature in the fridge.
E11
Fridge compartment is
too cold.
• Switch off the Extra Cool function.
• Set a higher temperature in the fridge.
• Make sure that ventilation holes are
clear and not clogged.
If the problems continue,
contact the Authorized
Service Centre.
In case of different problem with the
appliance, check the table below for
possible solutions.
9.2 What to do if...
Problem
Possible cause
Solution
The appliance does not
operate.
The appliance is switched
off.
Switch on the appliance.
The mains plug is not con‐
nected to the mains socket
correctly.
Connect the mains plug to
the mains socket correctly.
There is no voltage in the
mains socket.
Connect a different electri‐
cal appliance to the mains
socket. Contact a qualified
electrician.
The appliance is noisy.
The appliance is not sup‐
ported properly.
Check if the appliance
stands stable.
The compressor operates
continually.
Temperature is set incor‐
rectly.
Refer to "Operation" chap‐
ter.
Many food products were
put in at the same time.
Wait a few hours and then
check the temperature
again.
The room temperature is
too high.
Refer to "Installation" chap‐
ter.
Food products placed in
the appliance were too
warm.
Allow food products to cool
to room temperature be‐
fore storing.
The door is not closed cor‐
rectly.
Refer to "Closing the door"
section.
Door is misaligned or inter‐
feres with ventilation grill.
The appliance is not level‐
led.
Refer to installation instruc‐
tions.
ENGLISH