9.3 Other technical data
TOTAL POW‐
ER:
Gas original: G20 (2H) 20 mbar
7,65 kW
Gas replace‐
ment:
G30 (3+) 28-30 mbar
567 g/h
G31 (3+) 37 mbar
557 g/h
Electric sup‐
ply:
220-240 V ~ 50-60 Hz
3 core flexible cable with non rewireable plug fitted with a 3 amp car‐
tridge fuse
Appliance cat‐
egory:
II2H3+
Gas connec‐
tion:
R 1/2"
Appliance
class:
3
9.4 Gas burners for NATURAL GAS G20 20 mbar
BURNER
NORMAL POWER
kW
MINIMUM POWER
kW
INJECTOR MARK
Rapid
2,95
0,75
119°
Semi-rapid
1,85
0,6
92
Auxiliary
1,0
0,33
70
9.5 Gas burners for LPG G30/G31 28-30/37 mbar
BURNER
NORMAL
POWER
kW
MINIMUM
POWER
kW
INJECTOR
MARK
NOMINAL GAS FLOW g/h
G30 28-30
mbar
G31 37 mbar
Rapid
2,8
0,95
86
204
200
Semi-rapid 2,0
0,6
71
145
143
Auxiliary
1,0
0,33
50
73
71
10. ENERGY EFFICIENCY
10.1 Product Information according to UK Ecodesign Regulation
Model identification
KGS6424W,
KGS6424X
Type of hob
Built-in hob
Number of gas burners
4
www.electrolux.com
18
Содержание KGS6424W
Страница 1: ...KGS6424W KGS6424X EN Hob User Manual ...
Страница 20: ...www electrolux com shop 867345517 D 502021 ...