9.3 Other technical data
TOTAL POW‐
ER:
Gas original: G20/G25 (2E+) 20/25 mbar 7,65 kW
Gas re‐
placement:
G30 (3+) 28-30 mbar
567 g/h
G31 (3+) 37 mbar
557 g/h
G130 (1c) 8 mbar
8 kW
Electric supply: 220-240 V ~ 50-60 Hz
Appliance cat‐
egory:
3+
Gas connec‐
tion:
G 1/2"
Appliance
class:
3
9.4 Gas burners for NATURAL GAS G20/G25 20/25 mbar
BURNER
NORMAL POWER
kW
MINIMUM POWER
kW
INJECTOR MARK
Rapid
2,95
0,75
119°
Semi-rapid
1,85
0,6
92
Auxiliary
1,0
0,33
70
9.5 Gas burners for LPG G30/G31 28-30/37 mbar
BURNER
NORMAL
POWER
kW
MINIMUM
POWER
kW
INJECTOR
MARK
NOMINAL GAS FLOW g/h
G30 28-30
mbar
G31 37 mbar
Rapid
2,8
0,95
86
204
200
Semi-rapid 2,0
0,6
71
145
143
Auxiliary
1,0
0,33
50
73
71
9.6 Gas burners for TOWN GAS G130 8 mbar
BURNER
NORMAL POWER
kW
MINIMUM POWER
kW
INJECTOR MARK
Rapid
3,0
0,75
240
Semi-rapid
2,0
0,6
184x
Auxiliary
1,0
0,33
127
Installation kit to be ordered from
Authorised Service Centre.
ENGLISH
17
Содержание KGS6424K