Electrolux GWH 11 NanoPlus EU Скачать руководство пользователя страница 7

ENGLISH

7

Model of appliance type B11BS 

heater

The heater is equipped with an exhaust 

security thermostat.

If the exhaust outlet is not completely open, 

the thermostat is activated. Once the gas 

valve is closed, the heater will have an ignition 

once again after it has cooled off.

The activated temperature of anti-block 

protection thermostat is 75°C±5°C. When 

protection happens, electric circuit is cut and 

unit doesn’t work. The recovery temperature of 

the anti-block thermostat is 50°C±5°C. When 

it is recovered, the electric circuit is on. The 

unit works right. If the system stops working 

in 2 minute when the flue pipe is blocked, it 

means anti-block function is in protection. If 

not, please contact professional people to fix 

it following the rules of EN 26 standard.

Installation

•  The heater can only be installed inside a 

room. 

•  No installation of the heater in frost places. 

•  Keep the heater with good ventilation.

•  No cables or electric appliances can 

be placed on the heater. Keep the 

heater away from heat sources such as 

hearth. Please fulfill the cleaning and the 

maintenance for the heater according to 

relevant requirements of interval.

•  Please maintain a certain distance 

between vent-pipe and the ceiling of the 

room or other decorative objects.

•  Inflammable materials are banned from 

being placed less than 500mm away from 

the heater. If necessary, please install an 

outer insulating layer.

•  The heater must be installed onto a vertical 

wall in a correct vertical way.

•  The maximum pressure for which the 

appliance is designed, stating that even 

with the effects of water dilation, the water 

pressure in the appliance shall not exceed 

this value. 

•  The air flow in the circumstance around the 

gas water heater should be according to 

the follows

Model 

Gas category 

Air con-

sumption 

(m

3

/h)

GWH 11 NanoPlus EU

I2H

I3P(37)

I3B/P(30)

I3+(28-30/37)

21-33

GWH 14 NanoPlus EU

I2H

I3P(37)

I3B/P(30)

I3+(28-30/37)

26,8-42

Installation order

•  Confirm the drilling position according to 

the installation scheme or installation chart 

in the Speciation Table.

•  Open the close cover of the heater and 

pull out the operation button.

•  Screw off the fixed bolts in the lower part 

of the casing and then take off the casing.

•  Fix the heater.

•  Take off the plastic hoods used for 

connections of the heater.

•  Install the connectors.

•  Mount the casing and then replace the 

operation button.

Minimum distance/ ventilation 

The water heater is controlled by water flow 

rate to achieve on/off. Minimum starting water 

pressure is 0.3bar When there is water going 

through the water operated gas valve (water 

flow rate sitisfied with minimum water flow 

rate refers to specification table), the ignition 

will start to work and the gas valve will be 

energized.The un  it will be ON mode.

When the water flow is cut, the water gas 

valve will cut the gas valve as well. the unit will 

stop working.

Содержание GWH 11 NanoPlus EU

Страница 1: ...l your life with comfort Get quick access to instructions additional product information and support at our website home comfort com User s manual GB LT LV ET GAS Water heater Gāzes ūdens sildītājs Dujinis vandens šildytuvas Gaasi veesoojendi ...

Страница 2: ...E 5 12 MODIFICATION AND RENEWAL 5 13 SERVICE INSTRUCTION 5 14 INSTALLATION 7 15 TRIAL RUNNING 9 16 TROUBLESHOOTING 10 17 SPECIFICATIONS 11 18 DIMENSIONS AND SPECIFICATIONS 12 19 MAINTENANCE REGISTRATION TABLE 13 WE THINK ABOUT YOU Thank you for purchasing an Electrolux appliance You have chosen a product backed by decades of professional experience and innovations Unique and stylish it was created...

Страница 3: ...heater corresponds torequirements of CE standard and accord with the following directives EU 2016 426 legal Facilities directives of the Member States for Natural Gas Installation EN 26 water heaters in the sanitary equipped with atm ospheric gas burner with natural gas as fuel useandothersimilaruses Supplying details 1 x gas water heater 1 x Installation instructions 4 x bolts and tube expander 2...

Страница 4: ...wer supply before initiating cleaning and maintenance Neither the seals nor stamps can be destroyed If it is necessary for definitive rupturing operation please cut off all the connections respectively electrical power hydraulic power gas feeding exhaust pipe and make sure all of them are disconnected The heater and its components must be treated according to the locally effective prescriptions Th...

Страница 5: ...ing operation don t get close to any flammable and combustible materials or other similar ones Precautions for toxication Operation should be carried out according to the indications of the attached documents and instructions from the authorized professional installers to avoid toxication accidents which may cause death The heater can only be operated after being equipped with an exhaust pipe The ...

Страница 6: ... long period please conserve the heater in the following ways Close the switch of the gas Extract the batteries from the battery compartment Close the sealing valve at the cold water inlet Adjust the temperature regulator to the lowest temperature Turn on hot water switch Open the empty valve to empty out the water inside Close the empty valve Failure of the flame during the operation of the heate...

Страница 7: ... away from the heater If necessary please install an outer insulating layer The heater must be installed onto a vertical wall in a correct vertical way The maximum pressure for which the appliance is designed stating that even with the effects of water dilation the water pressure in the appliance shall not exceed this value The air flow in the circumstance around the gas water heater should be acc...

Страница 8: ...n in the following figure The manufacturer recommends the installation of a reductor on the cold water pipe In case of corrugated pipes the minimum bending radius shall be 20mm Connect the sealing valve to the attached cold water pipe Connect the sealing valve to the cold water input of the heater Connect the hot water output of the heater to the hot water pipe Installation of exhaust pipe Only af...

Страница 9: ...spare parts used for maintenance are not original the man ufacturer does not assume any quality guarantee The connecting pieces must be new Open the casing Before maintenance and repair please open the casing Screw off the two bolts on the casing at the lower part back of casing Take out the operation button Take off slipcover at the lower part of the casing gently press it upwards and then take i...

Страница 10: ... please replace them with new ones No hot water Open the distributor of hot water Low water temperature The gas valve is not completely on Open the gas valve completely During the operation of the water heater flame goes out The exhaust system is blocked Check whether the exhaust pipe is fluent or not When the water pressure is too low the rectifier of water pressure will be disconnected from the ...

Страница 11: ... h Max 2 32m3 h Min 0 84m3 h Max 2 95m3 h Min 0 94m3 h Efficiency of energy sources 88 88 Water supply pressure Max water pressure Pw bar 10 10 Min water pressure Pw bar 0 3 0 3 Max water flow 2bar L min 11 12 Min water flow 2bar L min 5 0 5 9 Connections Gas connection inch 1 2 1 2 Cold water connection inch 1 2 1 2 Hot water connection inch 1 2 1 2 Flue gas pipe diameter mm φ110 φ120 Maximum tem...

Страница 12: ...62 62 Re equipment or changing into other gas types is not allowed Dimensions and Specifications A BC D E F G 218 110 H 247 86 86 Dimensions and Specifications GWH 11 NanoPlus EU GWH 14 NanoPlus EU A 70 89 B 42 42 C 100 100 D 32 32 E 120 120 F 128 128 G 330 370 H 110 120 Manufacturer WUHU MIDEA KITCHEN BATH APPLIANCES MANUFACTURING CO LTD Importer SIA Green Trace LV 1004 Biekensalas iela 21 Riga L...

Страница 13: ...for maintenance Maintenance content Maintenance personnel Company Stamp signature Authenticator for maintenance Maintenance content Maintenance personnel Company Stamp signature Authenticator for maintenance Maintenance content Maintenance personnel Company Stamp signature Authenticator for maintenance Maintenance content Maintenance personnel Company Stamp signature Product Details populated upon...

Страница 14: ...14 www home comfort com ...

Страница 15: ...ENGLISH 15 ...

Страница 16: ... This manual may contain technical and typing errors Changes to technical characteristics and assortment are subject to change without notice Electrolux is a registered trademark used under license from AB Electrolux publ ...