Complaint.
Compressor Will Not Run.
Compressor Runs, but No Refrigeration.
Compressor Short Cycles.
Clause-Remedy
1.
No voltage at wall receptacle - check circuit breaker
or fuse.
2.
Service cord pulled out of the wall receptacle -
replace.
3.
Low voltage causing compressor to cycle on
overload. (Voltage fluctuation should not exceed 10%
plus or minus from normal rating.)
4.
Control thermostat dial in “Off” position - turn control
on.
5
Inoperative control thermostat - replaced control.
6.
Compressor stuck - replaced compressor.
7.
Compressor windings open - replace compressor.
8.
Defrost timer stuck in defrost - replace defrost timer.
9.
Compressor overload open - replace overload.
10. Relay lead loose - repair or replace Lead.
11. Relay leads or inoperative - replace relay.
12. Service cord pulled out of harness - repair
connection.
13. Faulty cabinet wiring - repair wiring.
1.
System out of refrigerant - check for leaks.
2.
Compressor not pumping - replaced compressor.
3.
Restricted filter-drier - replace filter-drier.
4.
Restricted capillary tube - replace.
5.
Moisture in the system - check for leaks in low side.
1.
Erratic control thermostat - replace control.
2.
Faulty relay - replace relay.
3.
Restricted airflow over condenser - insurer condenser
has unobstructed airflow.
4.
Low voltage - fluctuation exceeds 10%. (Call
qualified electrician.)
5.
Compressor draws excessive wattage - replaced
compressor