Section 4 Component Teardown
4-6
B. Servicing the touch control panel with power
supply from an external power source:
Disconnect the touch control panel completely from the
oven proper, and short both ends of the door sensing
switch (on PWB) of the touch control panel, which brings
about an operational state that is equivalent to the oven
door being closed. Connect an external power source to
the power input terminal of the touch control panel, then
it is possible to check and repair the controls of the touch
control panel; it is also possible to check the sensor-
related controls of the touch control panel by using the
dummy resistor(s).
Servicing Tools
Tools required to service the touch control panel
assembly.
1. Soldering iron: 60W (It is recommended to use a
soldering iron with a grounding terminal.)
2. Oscilloscope: Single beam, frequency range:
DC - 10MHz type or more advanced model.
3. Others: Hand tools
Other Precautions
1. Before turning on power source of the control unit,
remove the aluminium foil applied for preventing
static electricity.
2. Connect the connectors of the key unit to the control
unit, being sure that the lead wires are not twisted.
3. After aluminium foil is removed, be careful that
abnormal voltage due to static electricity etc. is not
applied to the input or output terminals.
4. Attach connectors, electrolytic capacitors, etc. to
PWB, making sure that all connections are tight.
5. Be sure to use specified components where high
precision is required.
Control Panel Assembly Removal
1. Disconnect the power supply cord and remove outer
case.
2. Open the door and block it open.
3. Discharge high voltage capacitor.
4. Disconnect the wire leads from panel components.
5. Remove the one (1) screw holding the control panel
assembly to the oven cavity front plate.
6. Slide control panel assembly upward and remove.
7. Now, individual components can be removed.
To discharge the high voltage capacitor, wait for 60
seconds and then short-circuit the connection of the
high-voltage capacitor (that is the connecting lead of
the high-voltage rectifier) against the chassis with the
use of an insulated screwdriver.
NOTE
NOTES FOR KEY UNIT REPLACEMENT
1. Before attaching a new key unit, wipe off remaining
adhesive on the control panel frame surfaces
completely with a soft cloth soaked in alcohol.
2. When attaching key unit to control panel frame,
adjust upper edge and right edge of the key unit to
the correct position of control panel frame.
3. Place the key unit firmly to the control panel frame
by rubbing with soft cloth not to scratch.
NOTE
Figure 4-4. Control Panel Removal
Содержание FGMO205KBA
Страница 2: ......
Страница 14: ...Section 2 Operation 2 2 Figure 2 1 Oven Off Condition Figure 2 2 Oven ON Cooking Condition ...
Страница 20: ...Section 3 Troubleshooting and Testing 3 2 ...
Страница 43: ...Section 5 Wiring Diagrams 5 1 Wiring Schematic Oven OFF Condition ...
Страница 44: ...Section 5 Wiring Diagrams 5 2 Wiring Diagram ...
Страница 45: ...Section 6 Parts List 6 1 Control Panel And Door Parts ...
Страница 46: ...Section 6 Parts List 6 2 ...
Страница 47: ...Section 6 Parts List 6 3 Oven And Cabinet Parts ...
Страница 48: ...Section 6 Parts List 6 4 Packing And Accessories ...