background image

&RQVWUXFWLRQ9LHZV

&RQVWUXFWLRQ9LHZV

,QGRRU8QLW

2XWGRRU8QLW

8QLWPP

320

776

510

714

257

286

540

912

188

290

135

143

60

Φ55

80

542

235

Φ55

Содержание EXI09HD1W

Страница 1: ...CE MANUAL AIR CONDITIONER MODEL EXI09HD1W EXI12HD1W Electrolux Home Products Italy S p A Corso Lino Zanussi 30 Publication number I 33080 Porcia PN 599 76 40 62 Fax 39 0434 394096 Edition 02 2013 Rev 0 0 EN ...

Страница 2: ......

Страница 3: ...UDWXUH 1RLVH ULWHULD XUYH 7DEOHV IRU RWK 0RGHOV 2SHUDWLRQ DWD RQVWUXFWLRQ 9LHZV QGRRU 8QLW 2XWGRRU 8QLW 5HIULJHUDQW 6 VWHP LDJUDP 6FKHPDWLF LDJUDP OHFWULFDO DWD OHFWULFDO LULQJ 3ULQWHG LUFXLW RDUG XQFWLRQ DQG RQWURO 5HPRWH RQWURO 2SHUDWLRQV HVFULSWLRQ RI DFK RQWURO 2SHUDWLRQ QVWDOODWLRQ 0DQXDO 1RWLFHV IRU QVWDOODWLRQ QVWDOODWLRQ UDZLQJ QVWDOO QGRRU 8QLW QVWDOO 2XWGRRU 8QLW ...

Страница 4: ...DLQWHQDQFH RI HDOWK LOWHU SORGHG 9LHZV DQG 3DUWV LVW QGRRU 8QLW 2XWGRRU 8QLW 7URXEOHVKRRWLQJ 0DOIXQFWLRQ QDO VLV ODVKLQJ RI QGRRU 2XWGRRU 8QLW DQG 3ULPDU XGJHPHQW RZ WR KHFN 6LPSO WKH 0DLQ 3DUW 5HPRYDO 3URFHGXUH 5HPRYDO 3URFHGXUH RI QGRRU 8QLW 5HPRYDO 3URFHGXUH RI 2XWGRRU 8QLW ...

Страница 5: ... 6XPPDU DQG HDWXUHV 6XPPDU DQG HDWXUHV QGRRU 8QLW 2XWGRRU 8QLW 5HPRWH RQWUROOHU ...

Страница 6: ...UDFWRU DV WKHUH LV WKH ULVN RI UH HOHFWULF VKRFN H SORVLRQ RU LQMXU Ɣ0DNH VXUH WKH RXWGRRU XQLW LV LQVWDOOHG RQ D VWDEOH OHYHO VXUIDFH ZLWK QR DFFXPXODWLRQ RI VQRZ OHDYHV RU WUDVK EHVLGH Ɣ0DNH VXUH WKH FHLOLQJ ZDOO LV VWURQJ HQRXJK WR EHDU WKH ZHLJKW RI WKH XQLW Ɣ0DNH VXUH WKH QRLVH RI WKH RXWGRRU XQLW GRHV QRW GLVWXUE QHLJKERUV Ɣ ROORZ DOO WKH LQVWDOODWLRQ LQVWUXFWLRQV WR PLQLPL H WKH ULVN RI GDP...

Страница 7: ... B 1 B 1 B 1 B 1 B QGRRU 8QLW DQ 7 SH URVV ÀRZ URVV ÀRZ QGRRU 8QLW DQ LDPHWHU HQJWK PP ĭ ĭ RROLQJ 6SHHG 6 0 U PLQ HDWLQJ 6SHHG 6 0 U PLQ QGRRU 8QLW DQ 0RWRU 3RZHU 2XWSXW QGRRU 8QLW DQ 0RWRU 5 QGRRU 8QLW DQ 0RWRU DSDFLWRU ȝ YDSRUDWRU RUP OXPLQXP LQ FRSSHU 7XEH OXPLQXP LQ FRSSHU 7XEH YDSRUDWRU 3LSH LDPHWHU PP ĭ ĭ YDSRUDWRU 5RZ Q DS PP YDSRUDWRU RLO HQJWK PP 6ZLQJ 0RWRU 0RGHO 03 03 6ZLQJ 0RWRU 3RZHU ...

Страница 8: ...GHQVHU 5RZV Q DS PP RQGHQVHU RLO HQJWK PP 2XWGRRU 8QLW DQ 0RWRU 6SHHG USP 2XWGRRU 8QLW DQ 0RWRU 3RZHU 2XWSXW 2XWGRRU 8QLW DQ 0RWRU 5 2XWGRRU 8QLW DQ 0RWRU DSDFLWRU ȝ 2XWGRRU 8QLW LU ORZ 9ROXPH P K 2XWGRRU 8QLW DQ 7 SH LDO ÀRZ LDO ÀRZ 2XWGRRU 8QLW DQ LDPHWHU PP ĭ ĭ HIURVWLQJ 0HWKRG XWRPDWLF HIURVWLQJ XWRPDWLF HIURVWLQJ OLPDWH 7 SH 7 7 VRODWLRQ 0RLVWXUH 3URWHFWLRQ 3 3 3HUPLVVLEOH FHVVLYH 2SHUDWLQJ 3...

Страница 9: ...ndition Indoor DB 20 Indoor air flow Turbo Pipe length 5m Voltage 230V Compressor Speed rps Cooling Heating Current A Current A 50 60 70 80 90 100 110 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 Capacity ratio Condition Indoor DB27 WB19 Indoor air flow Turbo Pipe length 5m Outdoor temp C 0 20 40 60 80 100 120 Capacity ratio Outdoor temp C g n i t a e H g n i l o o C EXI09HD1W EXI12HD1W EXI09HD1W ...

Страница 10: ...H FKDQJHU SDWK 8 EHQW 7KHUPLVWRU WKHPRPHWHU RQQHFWLQJ SLSLQJ FRQGLWLRQ P 3 7KH DLU SLSH SUHVVXUH JDV YDOYH VLGH SUHVVXUH FRQQHFW WR LQGRRU DQG RXGRRU XQLW 7 QOHW DQG RXWOHW SLSH WHPSHUDWXUH RI HYDSRUDWRU 7 QOHW DQG RXWOHW SLSH WHPSHUDWXUH RI FRQGHQVHU 7HPSHUDWXUH FRQGLWLRQ ć 0RGHO QDPH 6WDQGDUG SUHVVXUH HDW H FKDQJHU SLSH WHPS QGRRU IDQ PRGH 2XWGRRU IDQ PRGH USP RPSUHVVRU UHYROXWLRQ USV QGRRU 2XWG...

Страница 11: ... RQVWUXFWLRQ 9LHZV RQVWUXFWLRQ 9LHZV QGRRU 8QLW 2XWGRRU 8QLW 8QLW PP 320 776 510 714 257 286 540 912 188 290 135 143 60 Φ55 80 542 235 Φ55 ...

Страница 12: ...6 VWHP LDJUDP 5HIULJHUDQW SLSH GLDPHWHU LTXLG PP DV PP T I N U R O O D T U O T I N U R O O D N I HEAT EXCHANGER EVAPORATOR COOLING HEATING HEAT EXCHANGER EVAPORATOR Strainer Strainer Electron expansion valve Accumlator Compressor 4 Way valve ...

Страница 13: ... 7 50 1 2 1 52 1 8 8 0HDQLQJ RI PDUNV Ɣ QGRRU 8QLW L OUT L1 L1 0 0 RT1 RT2 M JUMP CAP TEM SENSOR ROOM TUBE TEM SENSOR FAN MOTOR SWING MOTOR U D AP2 SWING UD K4 TUBE ROOM AC L PG PGF DISP 1 DISP 2 CN2 CN1 AP1 DISPLAY 13 GENERATOR COOLPLASMA M PE XT1 W1BU W3BN N 1 OUTDOOR UNIT 2 3 COM OUT W4YEGN N W2BK BU YEGN BN L N POWER RD BU HEALTH N HEALTH L BU BK BN YEGN EVAPORATOR ...

Страница 14: ...C L1 L FAN OFAN COMP COMP AC N1 PE M PE PE MID ISOLATION SHEET ELECTRIC BOX 4YV AC N2 AP1 AP2 AC L AC N L1 L2 E AC L3 AC L2 LX1 2 LX1 1 OVC COMP COM OUT L1 PE CN1 CN3 BK BU BN BK BU YEGN YEGN YEGN YEGN YEGN BN BN BN BU BU BU BU BU RD RD YE YE TEM SENSOR OUTROOM EXHAUST TEM SENSOR T I N U R O O D N I L3 L2 L2 SAT RD W V U EKV CN1 θ θ θ L1 L4 L4 L4 X1 L4 NOTE Motor ground only applies to the iron sh...

Страница 15: ...e Port of indoor fan Solidstate relay Auto button Feedback of indoor fan Port of motor for horizontal swing Port of motor for vertical swing Buzzer Main chip Port of indoor ambient temp sensor Port of indoor pipe temp sensor Port of display Communication port Highfrequency transformer Power of switch Protective tube ...

Страница 16: ...QLW inductance pin1 inductance pin2 fan neilsbed four way valve compressor electric heater chassis electric heater compressor temp sensor overload protection electric expansion valve 10 core communication cable Ɣ 723 9 Ɣ 27720 9 ...

Страница 17: ...or timer adjustment Clock Button Press this button and the Clock symbol will blink You can press Control buttons and to set the time you want Temp Temperature Button Press this button to change the indoor unit display of the set temperature to the room temperature Eco Economy Button Press this button to start the Eco operation This is ideal for the users to use while sleeping Press again to cancel...

Страница 18: ...re It can be switched on off by pressing the Temp button Timer On Off Display Displays when the Timer On Off function is activated Fan Speed Display Displays the selected fan speed in the following sequence Low Medium High and Auto In Auto speed only symbol displays Swing Display Displays when the Swing function is selected X Fan Display Displays when the X Fan function is activated by pressing Tu...

Страница 19: ...mb Tpreset COOL mode will act the compressor and outdoor fan will run and the indoor fan will run at the set speed If Tamb Tpreset 2 the compressor will stop the outdoor fan will delay 30 seconds to stop and the indoor fan will run at the set speed If Tpreset 2 Tamb Tpreset the unit will keep running in the previous mode In this mode the reversal valve will not be powered on and the temperature se...

Страница 20: ...Q ZLOO EH VWDUWHG WKH LQGRRU IDQ ZLOO UXQ XQGHU SUHVHW FROG DLU SUHYHQWLRQ FRQGLWLRQV DQG ZLOO EH GLVSOD HG DW WHPSHUDWXUH GLVSOD DUHD RQ WKH GLVSOD SDQHO HIURVW IUHTXHQF LV Ĺ 3URWHFWLRQ ƹ ROG DLU SUHYHQWLRQ 7KH XQLW LV VWDUWHG XQGHU KHDWLQJ PRGH WKH FRPSUHVVRU LV 21 ķ Q WKH FDVH RI 7 LQGRRU DPE LI 7 WXEH DQG WKH LQGRRU IDQ LV DW VWRS VWDWH WKH LQGRRU IDQ ZLOO EHJLQ WR UXQ DW ORZ VSHHG ZLWK D WLPH...

Страница 21: ...UHFW VLJQDOV IRU GXUDWLYH PLQXWHV FRPPXQLFDWLRQ IDXOW FDQ EH MXVWL HG DQG WKH ZKROH V VWHP ZLOO VWRS ĺ 0RGXOH SURWHFWLRQ 8QGHU PRGXOH SURWHFWLRQ PRGH WKH FRPSUHVVRU ZLOO VWRS KHQ WKH FRPSUHVVRU UHPDLQV DW VWRS IRU DW OHDVW PLQXWHV WKH FRPSUHVVRU ZLOO UHVXPH LWV RSHUDWLRQ I PRGXOH SURWHFWLRQ RFFXUV VL WLPHV LQ VXFFHVVLRQ WKH FRPSUHVVRU ZLOO QRW EH VWDUWHG DJDLQ Ļ 2YHUORDG SURWHFWLRQ I WHPSHUDWXUH V...

Страница 22: ...J WLPH Q KHDWLQJ PRGH KHQ WKH LQLWLDO VHW WHPSHUDWXUH LV WKH XQLW ZLOO NHHS RQ UXQQLQJ DW WKLV WHPSHUDWXUH KHQ WKH LQLWLDO VHW WHPSHUDWXUH LV WKH WHPSHUDWXUH ZLOO GHFUHDVH E HYHU KRXU DIWHU VOHHS IXQFWLRQ LV VHW WKH WHPSHUDWXUH ZLOO QRW FKDQJH DIWHU GHFUHDVLQJ KHQ WKH LQLWLDO VHW WHPSHUDWXUH LV WKH WHPSHUDWXUH ZLOO GHFUHDVH E HYHU KRXU DIWHU VOHHS IXQFWLRQ LV VHW WKH WHPSHUDWXUH ZLOO QRW FKDQJH DI...

Страница 23: ...O PRYH WR FORFNZLVH XQGHU RWKHU PRGHV WKH XS DQG GRZQ DLU GHÀHFWRU ZLOO PRYH WR I RX VHW WKH VZLQJLQJ IXQFWLRQ ZKHQ RX VWDUW WKH PDFKLQH WKHQ WKH ZLQG EODGH ZLOO VZLQJ EHWZHHQ DQG 7KH DLU GHÀHFWRU KDV VZLQJLQJ VWDWHV RFDWLRQ RFDWLRQ RFDWLRQ RFDWLRQ RFDWLRQ RFDWLRQ WR RFDWLRQ VWRS DW DQ ORFDWLRQ EHWZHHQ WKH LQFOXGHG DQJOH EHWZHHQ a LV WKH VDPH 7KH DLU GHÀHFWRU ZLOO EH FORVHG DW RFDWLRQ DQG WKH VZLQ...

Страница 24: ...LFDOO I WKH ODVW UHPRWH FRQWURO FRPPDQG KDV QRW VHW WKH WLPHG IXQFWLRQ WKH V VWHP ZLOO UHPHPEHU WKH ODVW UHPRWH FRQWURO FRPPDQG DQG RSHUDWH DFFRUGLQJ LW I WKH ODVW UHPRWH FRQWURO FRPPDQG KDV VHW WLPHG IXQFWLRQ DQG WKH SRZHU VXSSO LV LQWHUUXSWHG EHIRUH WKH WLPHG WLPH WKH V VWHP ZLOO UHPHPEHU WKH WLPHG IXQFWLRQ RI WKH ODVW UHPRWH FRQWURO FRPPDQG WKH WLPHG WLPH ZLOO UHFRXQWHG IRUP SRZHU RQ I WKH ODVW...

Страница 25: ...R PDJQHWLF ZDYHV DUH JHQHUDWHG E UDGLR HTXLSPHQW ZHOGHUV DQG PHGLFDO HTXLSPHQW ƔVDOW ODGHQ DLU SUHYDLOV VXFK DV FORVH WR FRDVWDO DUHDV ƔWKH DLU LV FRQWDPLQDWHG ZLWK LQGXVWULDO YDSRXUV DQG RLOV ƔWKH DLU FRQWDLQV VXOSKXUHV JDV VXFK DV LQ KRW VSULQJ RQHV ƔFRUURVLRQ RU SRRU DLU TXDOLW H LVWV QVWDOODWLRQ 6LWH RI QGRRU 8QLW 7KH DLU LQOHW DQG RXWOHW VKRXOG EH DZD IURP WKH REVWUXFWLRQV QVXUH WKH DLU FDQ E...

Страница 26: ...G LQ HG ZLULQJ 1RWH Ɣ0DNH VXUH WKH OLYH ZLUH QHXWUDO ZLUH DQG HDUWK ZLUH LQ WKH IDPLO SRZHU VRFNHW DUH SURSHUO FRQQHFWHG 7KHUH VKRXOG EH UHOLDEOH FLUFXLW LQ WKH GLDJUDP Ɣ QDGHTXDWH RU LQFRUUHFW HOHFWULFDO FRQQHFWLRQV PD FDXVH HOHFWULF VKRFN RU UH DUWKLQJ 5HTXLUHPHQWV LU FRQGLWLRQHU LV W SH HOHFWULF DSSOLDQFH 3OHDVH HQVXUH WKDW WKH XQLW LV UHOLDEO HDUWKHG 7KH HOORZ JUHHQ ZLUH LQ DLU FRQGLWLRQHU LV ...

Страница 27: ... above 15cm above Space to the wall Space to obstruction 30cm above 2m above Air outlet side Air inlet side 30cm above 50cm above Space to the wall Space to the ceiling 15cm above Space to the wall 3 m a b o v e Air outlet side Space to the wall 50cm above ...

Страница 28: ... WKH GUDLQ KRVH GRZQZDUG VOLJKWO IRU VPRRWK GUDLQDJH RI FRQGHQVDWH 1RWH 7KH LQVXODWLQJ WXEH VKRXOG EH FRQQHFWHG UHOLDEO ZLWK WKH VOHHYH RXWVLGH WKH RXWOHW SLSH 7KH GUDLQ KRVH VKRXOG EH VODQWHG GRZQZDUG VOLJKWO ZLWKRXW GLVWRUWLRQ EXOJH RU ÀXFWXDWLRQ R QRW SXW WKH RXWOHW LQ WKH ZDWHU RQQHFWLQJ QGRRU DQG 2XWGRRU OHFWULF LUHV 2SHQ WKH IURQW SDQHO 5HPRYH WKH ZLULQJ FRYHU DQG ZLUH FODPS 0DNH WKH SRZHU F...

Страница 29: ...DWLRQ RI RQQHFWLRQ 3LSH OLJQ WKH FHQWHU RI WKH SLSH ÀDUH ZLWK WKH UHODWHG YDOYH 6FUHZ LQ WKH ÀDUH QXW E KDQG DQG WKHQ WLJKWHQ WKH QXW ZLWK VSDQQHU DQG WRUTXH ZUHQFK E UHIHUULQJ WR WKH IROORZLQJ 127 RQQHFW WKH FRQQHFWLRQ SLSH WR LQGRRU XQLW DW UVW DQG WKHQ WR RXWGRRU XQLW DQGOH SLSLQJ EHQGLQJ ZLWK FDUH R QRW GDPDJH WKH FRQQHFWLRQ SLSH QVXUH WKDW WKH MRLQW QXW LV WLJKWHQHG UPO RWKHUZLVH LW PD FDXVH ...

Страница 30: ...WHO OHFWULF ZLULQJ PXVW EH FRQQHFWHG FRUUHFWO DQG VHFXUHO XW RII YDOYHV RI WKH FRQQHFWLRQ SLSHV VKRXOG EH RSHQHG OO WKH LPSXULWLHV VXFK DV VFUDSV DQG WKUXPV PXVW EH FOHDUHG IURP WKH XQLW 2SHUDWLRQ 7HVW 0HWKRG 6ZLWFK RQ SRZHU DQG SUHVV 21 2 EXWWRQ RQ WKH UHPRWH FRQWUROOHU WR VWDUW RSHUDWLRQ 3UHVV 02 EXWWRQ WR VHOHFW WKH 22 7 1RW DYDLODEOH IRU FRROLQJ RQO XQLW 1 WR FKHFN ZKHWKHU WKH RSHUDWLRQ LV QRU...

Страница 31: ...LW DIWHU FOHDQLQJ DFFRUGLQJ WR WKH LQVWDOODWLRQ LQVWUXFWLRQ RQ W XVH EUXVK RU KDUG WKLQJV WR FOHDQ WKH OWHU IWHU FOHDQLQJ EH VXUH WR GU LW LQ WKH VKDGH 6HUYLFH LIH 7KH JHQHUDO VHULYH OLIH IRU WKH KHDOWK OWHU LV DERXW RQH HDU XQGHU QRUPDO FRQGLWLRQ V IRU VLOYHU LRQ OWHU LW LV LQYDOLG ZKHQ LWV VXUIDFH EHFRPHV EODFN JUHHQ Ɣ7KLV VXSSOHPHQWDU LQVWUXFWLRQ LV SURYLGHG IRU UHIHUHQFH WR WKH XQLW ZLWK KHDOW...

Страница 32: ... SORGHG 9LHZV DQG 3DUWV LVW SORGHG 9LHZV DQG 3DUWV LVW QGRRU 8QLW 34 33 35 22 16 15 14 13 17 39 40 41 42 18 19 20 21 24 25 26 27 28 29 30 31 32 36 37 38 12 11 10 9 8 7 5 6 3 1 23 2 4 ...

Страница 33: ...XVK 5HDU DVH DVV URVV ORZ DQ 2 DVNHW VXE DVV RI HDULQJ 5LQJ RI HDULQJ UDLQDJH KRVH DOO 0RXQWLQJ UDPH YDSRUDWRU VV YDSRUDWRU 6XSSRUW RQQHFWLQJ DEOH 3RZHU RUG RQQHFWLQJ SLSH FODPS DQ 0RWRU 0RWRU 3UHVV 3ODWH 5XEEHU 3OXJ DWHU 7UD 6WHSSLQJ 0RWRU UDQN OHFWULF R VV OHFWULF R 7HUPLQDO RDUG OHFWULF R RYHU DSDFLWRU XPSHU 7HPSHUDWXUH 6HQVRU 0DLQ RDUG 7HPSHUDWXUH 6HQVRU 6WD DU 6XE DVV LVSOD RDUG 5HPRWH RQWURO...

Страница 34: ...XVK 5HDU DVH DVV URVV ORZ DQ 2 DVNHW VXE DVV RI HDULQJ 5LQJ RI HDULQJ UDLQDJH KRVH DOO 0RXQWLQJ UDPH YDSRUDWRU VV YDSRUDWRU 6XSSRUW RQQHFWLQJ DEOH 3RZHU RUG RQQHFWLQJ SLSH FODPS DQ 0RWRU 0RWRU 3UHVV 3ODWH 5XEEHU 3OXJ DWHU 7UD 6WHSSLQJ 0RWRU UDQN OHFWULF R VV OHFWULF R 7HUPLQDO RDUG OHFWULF R RYHU DSDFLWRU XPSHU 7HPSHUDWXUH 6HQVRU 0DLQ RDUG 7HPSHUDWXUH 6HQVRU 6WD DU 6XE DVV LVSOD RDUG 5HPRWH RQWURO...

Страница 35: ...XVK 5HDU DVH DVV URVV ORZ DQ 2 DVNHW VXE DVV RI HDULQJ 5LQJ RI HDULQJ UDLQDJH KRVH DOO 0RXQWLQJ UDPH YDSRUDWRU VV YDSRUDWRU 6XSSRUW RQQHFWLQJ DEOH 3RZHU RUG RQQHFWLQJ SLSH FODPS DQ 0RWRU 0RWRU 3UHVV 3ODWH 5XEEHU 3OXJ DWHU 7UD 6WHSSLQJ 0RWRU UDQN OHFWULF R VV OHFWULF R 7HUPLQDO RDUG OHFWULF R RYHU DSDFLWRU XPSHU 7HPSHUDWXUH 6HQVRU 0DLQ RDUG 7HPSHUDWXUH 6HQVRU 6WD DU 6XE DVV LVSOD RDUG 5HPRWH RQWURO...

Страница 36: ...XVK 5HDU DVH DVV URVV ORZ DQ 2 DVNHW VXE DVV RI HDULQJ 5LQJ RI HDULQJ UDLQDJH KRVH DOO 0RXQWLQJ UDPH YDSRUDWRU VV YDSRUDWRU 6XSSRUW RQQHFWLQJ DEOH 3RZHU RUG RQQHFWLQJ SLSH FODPS DQ 0RWRU 0RWRU 3UHVV 3ODWH 5XEEHU 3OXJ DWHU 7UD 6WHSSLQJ 0RWRU UDQN OHFWULF R VV OHFWULF R 7HUPLQDO RDUG OHFWULF R RYHU DSDFLWRU XPSHU 7HPSHUDWXUH 6HQVRU 0DLQ RDUG 7HPSHUDWXUH 6HQVRU 6WD DU 6XE DVV LVSOD RDUG 5HPRWH RQWURO...

Страница 37: ... SORGHG 9LHZV DQG 3DUWV LVW 2XWGRRU 8QLW 13 2 16 25 11 5 22 23 7 8 4 10 3 6 1 12 14 9 24 26 17 15 19 20 21 18 ...

Страница 38: ...JH RQQHFWHU RPSUHVVRU DQG LWWLQJV D 9DOYH VV 9DOYH 6XSSRUW 3 XW RII 9DOYH VV XW RII 9DOYH 9DOYH 6XSSRUW ORFN 5LJKW 6LGH 3ODWH 6XE VV LJ DQGOH 0DJQHW RLO OHFWULF SDQVLRQ 9DOYH 6XE VV 5HDU ULOO OHFWULF R LOWHU RDUG 0DLQ RDUG OHFWULF R VV 7RS RYHU 6XE VV RQGHQVHU VV 0RWRU 6XSSRUW DQ 0RWRU 6PDOO DQGOH 7KH GDWD DERYH DUH VXEMHFW WR FKDQJH ZLWKRXW QRWLFH ...

Страница 39: ... SORGHG 9LHZV DQG 3DUWV LVW 13 2 16 25 11 5 22 23 7 8 4 10 3 6 1 12 14 9 24 26 17 15 19 20 21 18 ...

Страница 40: ...QDJH RQQHFWHU RPSUHVVRU DQG LWWLQJV D 9DOYH VV 9DOYH 6XSSRUW 3 XW RII 9DOYH VV XW RII 9DOYH 9DOYH 6XSSRUW ORFN 5LJKW 6LGH 3ODWH 6XE VV LJ DQGOH OHFWURQLF SDQVLRQ 9DOYH 0DJQHW RLO 5HDU ULOO OHFWULF R LOWHU RDUG 0DLQ RDUG OHFWULF R VV 7RS RYHU 6XE VV RQGHQVHU VV 0RWRU 6XSSRUW DQ 0RWRU 6PDOO DQGOH 7KH GDWD DERYH DUH VXEMHFW WR FKDQJH ZLWKRXW QRWLFH ...

Страница 41: ...ply circuit Power plug is not well plugged in and poor connection Check if the plug is properly plugged in and make the loose contact firm Fuse of controller burnt out The air condi tioner does not react after it is powered after the plug is inserted the buzzer does not sound and the remote startup has no response Remote controller malfunction Receiver loose or poor connection Receiver is broken C...

Страница 42: ...ion for the thick and thin pipes is good Heat insulation must also be provided for the joint andthe exposed part of the copper pipe Block of outdoor heat ex changer Clean the dust accumulated on the surface of the heat exchanger Air filter were blocked Clean the filter Fan speed was set too slow To set the fan speed to high or middle speed Air circulation is insufficient Fan rotation speed becomes...

Страница 43: ...stat is recommended Wrong wire connection Connect the circuit diagram correctly The built in heat protector of the motor breaks frequently because the motor is abnormal Replace the fan motor Adjust the volume of the refrigerant The refrigerant is not enough or is too much Replace the capillary The capillary is blocked and the tem perature rises The compressor does not run smoothly or is stuck The ...

Страница 44: ...ipe blocked or broken Change drainage pipe Re wrap and make it tight Wrap of refrigerant pipe joint is not close enough Water leakage Change controller Wire loose or wrong connection In cool heat mode the outdoor unit and compres sor will not run Correctly wire according to the drawing Improper setting of temperature Adjust setting temp Controller malfunction IC2003 broken creepage of parallel cap...

Страница 45: ... Overcurrent protection E5 OFF 3S and blink 5 times OFF 1S and blink 5 times During cooling and drying operation compressor and outdoor fan stop while indoor fan operates During heating operation all loads stop 1 Supply voltage is unstable 2 Supply voltage is too low and load is too high 3 Evaporator is dirty 6 Communi cation Malfunction E6 OFF 3S and blink Always 6 ON times During cooling operati...

Страница 46: ...nt temperature sensor is open short circuited F3 OFF 3S and blink 3 times OFF 1S and blink 6 times During cooling and drying operating compressor stops while indoor fan operates During heating operation the complete unit will stop operation Outdoor temperature sensor hasnt been connected well or is damaged Please check it by referring to the resistance table for temperature sensor 15 Outdoor conde...

Страница 47: ...T if the voltage is higher than 265VAC turn on the unit after the supply voltage is increased to the normal range 2 If the AC input is normal measure the voltage of electrolytic capacitor C on control panel AP1 if its normal theres malfunction for the circuit please replace the control panel AP1 22 Voltage of DC bus bar is too low PL OFF 3S and blink 21 times OFF 1S and blink 12 times During cooli...

Страница 48: ...s of capacitor 29 Malfunction of module temperature sensor circuit P7 OFF 3S and blink 18 times During cooling and drying operation compressor will stop while indoor fan will operate During heating operation the complete unit will stop Replace outdoor control panel AP1 30 Module high temperature protection P8 OFF 3S and blink 19 times During cooling operation compressor will stop while indoor fan ...

Страница 49: ... Fan motor is stalling 4 Motor malfunction 5 Malfunction of mainboard rev detecting circuit 38 Desynchro nizing of compressor H7 OFF 3S and blink 7 times During cooling and drying operation compressor will stop while indoor fan will operate During heating operation the complete unit will stop operation Refer to the malfunction analysis IPM protection loss of synchronism protection and overcurrent ...

Страница 50: ... 46 Malfunction of complete units current detection U5 OFF 3S and blink 13 times During cooling and drying operation the compressor will stop while indoor fan will operate During heating operating the complete unit will stop operation Theres circuit malfunction on outdoor units control panel AP1 please replace the outdoor units control panel AP1 47 The four way valve is abnormal U7 OFF 3S and blin...

Страница 51: ... of display status and during blinking ON 0 5s and OFF 0 5s Operation Indicator Cool Indicator Heating Indicator Yellow Indicator Red Indicator Green Indicator 53 Normal communica tion 54 Defrosting OFF 3S and blink once during blinking ON 10s and OFF 0 5s OFF 0 5S and blink once OFF 1S and blink twice Defrosting will occur in heating mode Compressor will operate while indoor fan will stop operati...

Страница 52: ...he voltage testing circuit on control panel AP1 Replace the control panel AP1 Measure the AC voltage between terminalL andN on wiring board XT power supply Voltage within 210VAC 250VAC Shut down the power and repair the power supply to restore the range 210VAC 250VAC power on and restart the unit If the fault is eliminated Shut down the power and wait 20 minutes or use DC voltmeter to measure the ...

Страница 53: ...her conditions resulting in that the system pressure becomes too high The connection of capacitor C2 is loose Reconnect the capacitor C2 according to Electrical Wiring Diagram Then Restart the unit Stop the unit and disconnect the power supply Wait 20 minutes or use DC voltmeter to measure the voltage between the two ends of capacitor C2 until the voltage is lower than 20V Replace the capacitor C2...

Страница 54: ...otection Is outdoor ambient temperature higher than 53 20 minutes after the complete unit is powered off Is heat dissipation of the indoor unit and outdoor unit abnormal Normal protection please operate it after the outdoor ambient temp erature is normalized Improve the heat dissipation environ ment of the unit Does the outdoor fan work normally 1 Check if the fan terminal OFAN is connected correc...

Страница 55: ... VWRSSLQJ HQRXJK DXOW GLDJQRVLV SURFHVV Y N Y N N Y Y N Power on the unit Is stop time of the compressor longer than 3 minutes Restart it up after 3 minutes Does startup fail Are the wires for the compressor connected correctly Is connection sequence right Connect the wires as per the connection diagram Replace the control panel AP1 If the fault is eliminated Replace the compressor End ...

Страница 56: ...mpressor connected correctly Is connection sequence right Is the connection made in clockwise direction Connect the wires correctly Replace the control panel AP1 If the fault is eliminated Replace the compressor End Out of step occurs in operation Is the outdoor fan working normally Is the outdoor unit blocked by foreign objects Replace the control panel AP1 If the fault is eliminated Replace the ...

Страница 57: ...fter the complete unit is powered off Is the terminal FA for the electronic expansion valve connected correctly Connect the wires correctly Resistances between the first four pins close to the terminal hole and the fifth pin are almost the same less than 100 ohm Replace the electronic expansion valve If the fault is eliminated If the fault is eliminated Replace the control panel AP1 Coolant leakag...

Страница 58: ...ircuit Replace it as per the wiring diagram and reconnect the wires If the fault is eliminated Remove the PFC capacitor and measure resistance between the two terminals Is the resistance around zero The capacitor is short circuited and the capacitor should be repla ced Restart the unit If the fault is eliminated Disconnect the terminals for the reactor and measure the resistance between the two te...

Страница 59: ...ally before the failure occurs The AP1 voltage detection circuit is at fault Check wiring inside of the indoor and outdoor units Are wires broken Check the communication circuit of the outdoor unit If the fault is eliminated The communication circuit is abnormal Replace the main board of the indoor unit End If the fault is eliminated Replace the main board AP1 of the outdoor unit If the fault is e...

Страница 60: ...XQLYHUVDO PHWHU YROWDJH RI ERWK VLGHV RI 5 7KH YROWDJH VKRXOG EH YDULDEOH 7HVW 7HVW WKH YROWDJH RI SLQ DQG SLQ RI 8 ZLWK XQLYHUVDO PHWHU YROWDJH RI ERWK VLGHV RI 5 7KH YROWDJH VKRXOG EH YDULDEOH 7HVW 2WKHUZLVH WKHUH LV PDOIXQFWLRQ RI PDLQERDUG RI RXWGRRU XQLW 7HVW WKH YROWDJH RI SLQ DQG SLQ RI 8 ZLWK XQLYHUVDO PHWHU YROWDJH RI ERWK VLGHV RI 5 7KH YROWDJH VKRXOG EH YDULDEOH WHVW 7HVW WKH YROWDJH RI...

Страница 61: ... at the Test 15 position as shown in the diagram with a voltmeter Value jumping Measure voltage at the Test 11 position as shown in the diagram with a voltmeter Value jumping Measure voltage at the Test 12 position as shown in the diagram with a voltmeter Value jumping The communication circuit of the outdoor unit is normal End Fault with outdoor unit ...

Страница 62: ... 7URXEOHVKRRWLQJ SSHQGL 5HVLVWDQFH 7DEOH RI PELHQW 7HPSHUDWXUH 6HQVRU IRU QGRRU DQG 2XWGRRU 8QLWV 7HPS ć 5HVLVWDQFH Nȍ 7HPS ć 5HVLVWDQFH Nȍ 7HPS ć 5HVLVWDQFH Nȍ 7HPS ć 5HVLVWDQFH Nȍ SSHQGL ...

Страница 63: ... 7URXEOHVKRRWLQJ SSHQGL 5HVLVWDQFH 7DEOH RI 2XWGRRU DQG QGRRU 7XEH 7HPSHUDWXUH 6HQVRUV 7HPS ć 5HVLVWDQFH Nȍ 7HPS ć 5HVLVWDQFH Nȍ 7HPS ć 5HVLVWDQFH Nȍ 7HPS ć 5HVLVWDQFH Nȍ ...

Страница 64: ...EOHVKRRWLQJ 1RWH 7KH LQIRUPDWLRQ DERYH LV IRU UHIHUHQFH RQO SSHQGL 5HVLVWDQFH 7DEOH RI 2XWGRRU LVFKDUJH 7HPSHUDWXUH 6HQVRU 7HPS ć 5HVLVWDQFH Nȍ 7HPS ć 5HVLVWDQFH Nȍ 7HPS ć 5HVLVWDQFH Nȍ 7HPS ć 5HVLVWDQFH Nȍ ...

Страница 65: ... 5HPRYH OWHU D E F 5HPRYH SDQHO 3XVK WKH URWRU VKDIW RQ ERWK VLGHV RI WKH SDQHO WR PDNH LW VHSDUDWH IURP WKH JURRYH 5HPRYH WKH SDQHO RRVHQ WKH FODVSV RQ OWHU VXE DVV SXVK WKH OWHU LQZDUGV DQG WKHQ SXOO LW XSZDUGV WR UHPRYH LW 2SHQ IURQW SDQHO UHPRYH VFUHZV IL LQJ LQGLFDWRU DQG ORRVHQ FODVSV RI VXSSRUW 7KHQ UHPRYH LQGLFDWRU DQG VXSSRUW HIRUH GLVDVVHPEO LQGLFDWRU IURQW SDQHO VXSSRUW OWHU ...

Страница 66: ...RQWDO ORXYHU HQG WKH ORXYHU RXWZDUGV DQG WKHQ UHPRYH WKH RXYHU 5HPRYH IURQW FDVH 5HPRYH WKH VFUHZV FRQQHFWHG ZLWK IURQW FDVH DQG ERWWRP FDVH RSHQ WKH VFUHZ FDS DQG WKHQ UHPRYH WKH RWKHU VFUHZ RRVHQ WKH FODVS FRQQHFWHG ZLWK IURQW FDVH ERWWRP FDVH SXOO LW XSZDUGV DQG WKHQ UHPRYH WKH SDQHO VXE DVV IURQW FDVH RRVHQ WKH FODVSV FRQQHFWLQJ WKH VZLQJ EODGH DQG ERWWRP FDVH DQG WKHQ UHPRYH WKH VZLQJ EODGH D...

Страница 67: ...H WKH HOHFWULF ER FRYHU 5HPRYH WKH VFUHZV FRQQHFWLQJ HOHFWULF ER DQG ERWWRP FDVH ORRVHQ WKH FODVSV UHPRYH WKH VFUHZV FRQQHFWLQJ WKH HUDWK LQJ ZLUH DQG HYDSRUDWRU SXOO RXW WKH LQ GRRU URRP WHPSHUDWXUH VHQVRU DQG WKHQ UHPRYH WKH HOHFWULF ER E 5HPRYH HYDSRUDWRU 7XUQ RYHU WKH ERWWRP FDVH UHPRYH WKH VFUHZV FRQQHFWLQJ WKH FRQQHFWLQJ SLSH FODPS DQG ERWWRP FDVH ORRVHQ WKH FODVSV EHWZHHQ FRQQHFWLRQ SLSH FO...

Страница 68: ...PRWRU DQG WKHQ UHPRYH WKH VWHSSLQJ PRWRU 3URFHGXUH 6WHSV D 5HPRYH WKH VFUHZV FRQQHFWLQJ WKH PRWRU FODPS DQG ERWWRP FDVH DQG WKHQ UHPRYH WKH PRWRU FODPS E F 5HPRYH WKH VFUHZV FRQQHFWLQJ WKH URVV ORZ DQ DQG DQ 0RWRU DQG WKHQ UH PRYH WKH URVV ORZ DQ DQG DQ 0RWRU URVV ORZ DQ DQ 0RWRU 2 DVNHW VXE DVV RI HDULQJ 0RWRU ODPS ...

Страница 69: ...II DOO SRZHU VXSSOLHV EHIRUH GLVDVVHPEO Procedure Steps 1 Remove big handle 2 Remove top cover top cover big handle Before disassamble Remove 1 connection screw fixing big handleand then removethe big handle Remove 3 connection screws among top cover plate front panel and right sideplate Then remove top cover plate ...

Страница 70: ...he front grille Remove connection screws connecting the front panel with the chassis and the motor support and then remove the front panel Remove the nut fixing the blade and then remove the axial flow blade Remove connection screws connecting the right side plate with the valve support and the electric box Then remove the right side plate Grille Panel Axial flow blade Right side plate ...

Страница 71: ... weld spots connecting the 4 way Valve Assy to take it out Note Refrigerant should be discharged firstly Welding process should be as quickly as possible and keep wrapping cotton wet all the time Be sure not to burn out the lead out wire of compressor 7 Remove 4 way valve assy 8 Remove capillary sub assy Unsolder weld point of capillary Sub assy valve and outlet pipe of condensator Then remove the...

Страница 72: ...he 2 tapping screws fixing the motor support Lift motor support to re move it 9 Remove motor and motor support Motor Motor support 10 Remove clapboard sub assy Loosen the screws of the Clapboard Sub Assy The Clapboard Sub Assy has a hook on the lower side Lift and pull the Clapboard Sub Assy to remove Clapboard Sub Assy ...

Страница 73: ...return pipe and remove the gas valve Note it is necessary to warp the gas valve when unsoldering the welding spot Remove the 2 screws fixing liquid valve Unsolder the weld ing spot connecting liquid valve and remove the liquid valve 2 Remove the 3 footing screws of the compressor and remove the compressor Compressor Gas valve Liquid valve ...

Страница 74: ... ...

Отзывы: