SOI/DT 2004-11 dmm
61/67
599 36 75-68
14 Operating time counter
It is possible to display, with a specific procedure, the operating time of the appliance, which is counted from
the first switching on.
This option is available only in models with display. The maximum memorization capacity is
6550
operating
hours.
Only the operating time of normal programmes is displayed (not diagnostics cycles)
The actual time of the cycle performed is counted (not the pauses, the delayed start time, rinse hold and
the soak phases)
The memorization is 30 seconds for each programme
Only operating hours are displayed (1h and 59min = 1h)
14.1.1 Operating time reading
Version with ON/OFF button
Version with ON/OFF button incorporated in the
selector
1. Reset the set programme and switch the
appliance off.
2. Rotate the programme selector of
three
positions clockwise.
3. Press
the
start/pause
(8) and
anyone
of the
option buttons simultaneously and then, holding
the buttons down,
switch the appliance on
with the
ON/OFF button (on/off)
4. Keep the start/pause and option buttons down
till the LEDs start flashing (about 5 seconds).
1. Cancel the set programme and switch the
appliance off.
2. Press
the
start/pause
(8) and
anyone
of the
option buttons simultaneously and then, holding
the buttons down, switch the appliance on
rotating the programme selector of
three
positions clockwise.
3. Keep the start/pause and option buttons down
till the LEDs start flashing (about 5 seconds).
14.1.2 Displaying the operating time
The operating time is displayed two digits at a time: the first pair of digits shows the thousands and
hundreds; the second pair shows tens and units.
For example, a total operating time of
6,550
hours will be displayed as follows:
1
→
2
→
3
→
Blank display for two seconds
The first pair of digits is
displayed for two seconds:
-
thousands (
6
)
-
hundreds (
5
)
The second pair of two digits is
displayed for two seconds:
-
tens (
5
)
-
units (
0
)