background image

 

 

Reversible 

tempered 

double/triple 

pane 

smoked  glass  door  protects  your  wine  from 
UV light and creates an attractive display with 
few condensation and low noise.

 

 

Black  coated  matte  steel  outer  frame  and 
black  plastic  interior  liner  offer  lifetime 
performance  and  stability.  The  black  liner 
prevents  excessive  light  from  damaging  the 
maturity process.

 

 

Optional  stainless  steel-framed  glass  door 
with stainless steel handle.

 

 

Optional 

roll-out 

and 

adjustable 

solid 

varnished  beech  shelves  allow  for  maximum 
convenience  and  flexibility  to  accommodate 
various size bottles.

 

 

Environmentally 

friendly 

refrigerant 

and 

foaming insulation gas.

 

 

Optional security lock system with keys.

 

 

Optional  humidity  control  system  (Humidity 
Box).

 

 

Optional active charcoal air filter.

 

 

INSTALLATION 

 
BEFORE USING YOUR APPLIANCE 

 

 

Remove  all  exterior  and  interior  packing. 
Clean the interior surface with lukewarm water 
using a soft cloth. The unit may have residual 
odors  at  first,  they  will  disappear  as  the  unit 
cools. 

 

 

Before connecting the appliance to the power 
source,  let  it  stand  upright  for  at  least  24 
hours.  This  will  reduce  the  possibility  of  a 
malfunction  in  the  cooling  system  caused  by 
handling  during  transportation.  During  this 
time  we  recommend  that  you  leave  the  door 
open to clear any residual odors. 

 

 

The  door  on  this  appliance  can  be  opened 
from either the left or the right side. The unit is 
delivered  with  the  door  opening  on  the  left 
side.  Should  you  wish  to  open  the  door  from 
the right, follow the instructions ‘Reversing the 
door hinge’. 

 

 

Install the handle on the door if necessary. 

 

INSTALLATION OF YOUR APPLIANCE 
 

 

The  appliances  are  designed  to  be  built-in  or 
recessed or free standing installation.  

 

 

WARNING

:  Do  not  store  or  install  the 

appliance outdoors. The unit is for indoor  use 
only.

 

 

 

WARNING

:  Do  no  install  the  appliance  in  the 

laundry

Avoid locating the unit in damp areas. 

 
 
 

 

Place  your  appliance  on  a  floor  that  is  strong 
enough  to  support  it  when  it  is  fully  loaded.  To 
level your unit, adjust the front leveling leg at the 
bottom of the unit. 

 

 

For  freestanding  installation,  100mm  of  space 

between  the  back  and  sides  of  the  unit  are 
suggested,  which  allows  the  proper  air 
circulation  to  cool  the  compressor  and 
condenser  for  energy  saving.  Even  for  built-in 
installation,  it  is  a  must  to  keep  5mm  space  on 
each  side  and  at  the  top  to  ensure  proper 
service  access  and  ventilation.  Take  care  that 
the  air  vent  at  the  front  of  the  appliance  must 
never be covered or blocked in any way.  

 

 

Locate  the  unit  away  from  direct  sunlight  and 
sources  of  heat  (stove,  heater,  radiator,  etc.). 
Direct sunlight may affect the acrylic coating and 
heat 

sources 

may 

increase 

electrical 

consumption. 

Extreme 

cold 

ambient 

temperatures  may  also  cause  the  unit  not  to 
perform properly. 

 

 

Plug the unit into an exclusive, easily accessible 
plug  socket.  Any  questions  concerning  power 
and/or  earthing  should  be  directed  towards  a 
qualified  electrician  or  an  authorized  products 
service centre. 

 

 

The appliance must be installed to all  electrical, 
plumbing,  water  and  drain  connections  in 
accordance with state and local codes. 

 

 

IMPORTANT:  HIGH  HUMIDITY  CLIMATE.

 

During 

periods 

of 

high 

humidity, 

some 

condensation may appear on outside surfaces of 
glass  door.  This  condensation  will  disappear 
when  humidity  levels  drop.  For  prevention,  it  is 
advisable  to  install  the  appliance  with  sufficient 
ventilation  in  a  dry  and/or  an  air-conditioned 
place. 

 
 
 
 
 

BUILT-UNDER INSTRUCTIONS 

Make sure your installation does not block the front 
ventilation grille.

 

If the unit is installed for fitting 

kitchen plinth, make sure that the ventilation gaps in 
the plinth are at least 300 square centimeters and 
remove the ventilation grilles, so that warm air can 
disperse unhindered. Otherwise the appliance has 
to work harder, resulting in an increase in electricity 
consumption. 
 

NOTE:

 When  pushing  the  appliance  into  the  niche, 

make  sure  that  the  mains  cable  does  not  get 
trapped. 
 
 
 
 

NOTE: The appliance must be positioned so 
that the plug is accessible.  

Содержание EWK0462X

Страница 1: ...Wine Cellar Instruction Manual EWK0462X EWK1262X Please read this manual carefully before it is installed and used for the first time It is essential to keep it for future reference ...

Страница 2: ...oid a hazard The use of attachments not recommended by the manufacturer may be hazardous Place the unit on a dry level surface Do not operate if the housing is removed or damaged A loose fit between the AC outlet receptacle and plug may cause overheating and a distortion of the plug Contact a qualified electrician to replace loose or worn outlet Locate the unit away from direct sunlight and source...

Страница 3: ... the back of this manual It lists causes of minor operating problems that you can correct by yourself DISPOSAL Dispose of your appliance packaging properly Ensure that any plastic wrappings bags etc are disposed of safely and kept out of the reach of babies and young children Danger of suffocation Refrigeration equipment must be properly disposed of in a professional and appropriate way in accorda...

Страница 4: ...e 92 31 EEC with respect to Electromagnetic Compatibility NON REWIREABLE MAINS PLUG If your appliance is supplied with a non rewireable plug fitted to the mains lead you will find that it incorporates a fuse the value of which is indicated either on the base of the plug or on the fuse carrier Should the fuse need replacing you must use an ASTA approved one conforming to BS1362 of the same rating I...

Страница 5: ...nce on a floor that is strong enough to support it when it is fully loaded To level your unit adjust the front leveling leg at the bottom of the unit For freestanding installation 100mm of space between the back and sides of the unit are suggested which allows the proper air circulation to cool the compressor and condenser for energy saving Even for built in installation it is a must to keep 5mm s...

Страница 6: ...0 1772 620 1768 680 ELECTRICAL CONNECTION WARNING Improper use of the grounded plug can result in the risk of electrical shock If the power cord is damaged have it replaced by a qualified electrician or an authorized service center All electrical work should be carried out by a suitably qualified and competent person in accordance with local and national safety regulations Check that the voltage m...

Страница 7: ...tion 2 Install the handle 4 tightly as shown above with two screws 3 and flat washers 2 provided 3 Replace the door gasket REVERSING THE DOOR HINGE It is possible to reverse the door on this appliance if required To do so follow the steps below DESIGN 1 1 Remove the adjustable ventilation grille 2 by unscrewing the screws 1 and then remove the ventilation grille 4 by unscrewing the screws 3 Fig 1 ...

Страница 8: ...e left top hinge 8 included in the fittings on the left hand side of cabinet Fig 3 5 Unscrew and transfer the lower hinge bracket 5 and door supporter to the opposite side At the same time remove the stopper pin 4 to the opposite designated position of the lower hinge bracket Fig 1 6 Relocate the door shaft assembly to the designated position 7 Relocate the glass door to the designated position Th...

Страница 9: ...t the appliance is unplugged and after careful cleaning leave the door ajar to allow air to circulate inside the cabinet in order to avoid possible condensation mold or odours forming OPERATING YOUR APPLIANCE This appliance is designed for operation at certain ambient temperatures The climate class is specified on the rating plate The appliance may not work properly if it is left for a long period...

Страница 10: ...C 41ºF and 72ºF The LOWER RIGHT temperature zone is ideal for storing white and red wine at a setting of 13 C to 22 C 55 F to 72 F The UPPER LEFT temperature zone is suitable for storing champagne and white wine at a setting of 5 C to 13 C 41 F to 55 F When the unit is plugged in for the first time the unit will power up automatically to the preset defaults The preset temperature at the factory fo...

Страница 11: ...gain INTERIOR LIGHT The interior light makes it easy to view your wine labels and enhances the display of your collection Touching the LIGHT mark toggles between 2 modes of operation for the internal lights functional default mode and showcase mode If you are in functional default mode the lights will turn on only when the door is open If you are in showcase mode the lights will be on whether or n...

Страница 12: ...member that the noise of the compressor and the coolant circulating in the system is unavoidable DEFROSTING HYGROMETRY VENTILATION Your unit is designed with an automatic defrost system During the Off cycle the evaporator behind the rear wall of the unit defrosts automatically The condensate collects in the drain trough behind the rear wall of the unit and part of it flows through the drainage hol...

Страница 13: ... wines see Wine Serving Temperature Chart above This being said and as it is for natural cellars used by wine producers for long period of storage it is not the exact temperature that is important but its consistency In other words as long as the temperature of your wine cellar is constant between 11ºC to 14ºC your wines will be stored in perfect conditions Not all wines will improve over the year...

Страница 14: ... mild liquid detergent Rinse well and wipe dry with a clean soft cloth Do not clean the stainless steel with steel wool pads Suggest to using an all in one stainless steel cleaner to clean the stainless steel and always clean in the direction of grain POWER FAILURE In the event of a power interruption all previous temperature settings are automatically memorized If power is interrupted power surge...

Страница 15: ...liance with a blanket or similar item ENERGY SAVING TIPS The appliance should be located in the coolest area of the room away from heat producing appliances and out of the direct sunlight Ensure that the unit is adequately ventilated Never cover air vents Clean dust and dirt from the condenser at regular intervals Only open the door for as long as necessary and for as short a time as possible Stor...

Страница 16: ...iance in a cooler place Leave the appliance to work for a while until the set temperature has been reached Do not open the door more often than necessary Close door properly Check the door seal and clean or replace The light does not work Appliance is not connected to a power supply The circuit breaker tripped or a blown fuse The light was switched off on the control panel Connect the appliance Sw...

Страница 17: ...Do not open the door more often than necessary Clear the obstructions and clean the dust Leave the appliance to work for a while until the set temperature has been reached The icon is lit up and flashing in the temperature display The display temperature is out of the range Only temperatures within the range 0 99 F 9 37 C the appliance can display will be shown If the temperature is not within thi...

Отзывы: