Fig. 6
Fig. 7
Fuse Distributor Board
Miniature Circuit Breaker (MCB)
FUSE
ON / OFF Double Pole Switch
ON/OFF
Double PVC Cable
Cable
NOTE: Refer to Table 1
for electrical loading
and correct size of
wire conductor
Position
this way
Screw A
METHOD OF ALIGNMENT WHEN REPLACING FRONT COVER
ELECTRICAL INSTALLATION DIAGRAM
(Off Position)
8
www.electrolux.com
5. ELECTRICAL INSTALLATION
5. ELECTRICAL INSTALLATION (CON
’D)
Screw A
Position
this way
(Off Position)
‘A’
Brown or red: LIVE (L)
Blue or Black: NEUTRAL (N)
Green or Green/Yellow: Earth ( )
Ensure the power cord
DOES NOT touch
copper flange
Fig. A
Fig. B
9
ENGLISH
‘B’
5.1 All electrical work must comply with national and
applicable state and local electrical codes.
5.2 This appliance must be earthed. Improper grounding
could cause electrical shock.
5.3
5.4
5.5 Use double insulation cable of over 4mm.
5.6
Remember to SWITCH OFF the mains before
carrying out any electrical work.
Refer to TABLE 1 for the correct cable size.
Insert the wall embedded cable through Side Entry ‘A’
by cutting a hole at the source cord rubber holder and lead
the cable to Cable Bracket ‘B’ (Fig. 7).
WARNING!
2
5.7
Connect the cable as follows:
Brown or Red: LIVE (L)
Blue or Black: NEUTRAL (N)
Green or Green/Yellow: EARTH ( )
PROCEDURE :
5.8 Clamp the cable to the correct position.
CHECK IF THE WIRING CONNECTION IS
CORRECT and replace the cover.
5.9 When putting back the Front Cover,
please take note of the
procedure shown below :
-Ensure the position is correct, turn the
Temperature Control Knob Insert to OFF
position as shown in Fig.A (At the Heater Base)
-Install the Front Cover,turn the Temperature
Control Knob to OFF position to align with the
VR shaft as shown in Fig.B (At the Front Cover)
5.10 Fix the Temperature Control Knob and
screw ‘A’ .