48
Switches and indicators
A) On/off indicator
green
B) Thermostat and on/off switch
C) Quick freeze indicator
yellow
D) Acoustic signal stop and quick freeze switch
E) Alarm indicator
red
Operation and use
Installation
Insert the plug into the socket. In order to switch on
the product, turn the thermostat
(B)
to a temperature
lower than << -16 C >>. The green, yellow and red
indicators will light up. The lighting up of the on/off
indicator
(A)
means that the product is switched on.
The yellow indicator lights continuously indicating an
uninterrupted refrigeration for 5 hours (it can be
switched off manually after 2 hours). The red indicator
lights continuously indicating an improper temperature
in the freezing compartment.
As well as an intermittent
sound can be heard, which can be stopped by pressing
button
(D)
once.
You can switch off the freezer by
turning the thermostat
(B)
in position << >>.
When the product is switched on for the first
time, the quick freeze function will start
automatically and will stop only 5 hours later. You
can manually switch off this function any time by
pressing the quick freeze (D) switch.
Adjusting the temperature
The internal temperature of the freezer is regulated
electronically through five temperature positions and a
switch-off << " >> setting.
Position << -16°C >> indicates the highest (least cold)
temperature, while position << -24°C >> is for the
lowest (coldest) temperature. Rotate the thermostat in
the desired position.
In general, it is best to set the thermostat to << -18°C
>> but, for the purpose of temperature setting, you
should also consider
the temperature of the room where the product is
installed,
the frequency of door openings,
the volume of food to be stored in the product,
the location of the product.
Therefore, you should consider all these factors and
you may have to do some testing for finding the best
temperature. If you want a lower temperature, turn the
thermostat into a position of higher number or, vice
versa, if you need a higher temperature, you should
set a position of lower number. Please allow 24 hours
for the freezer temperature to stabilize between two
adjustments.
Alarm (red) indicator
The temperature alarm indicator
(E)
will light up when
the internal temperature of the freezer increases to a
GB