![Electrolux EPN09C38HW Скачать руководство пользователя страница 22](http://html.mh-extra.com/html/electrolux/epn09c38hw/epn09c38hw_user-manual_90308022.webp)
22 www.electrolux.com
air outlet position and select HIGH
fan speed.
8. Heating mode (For cooling and
heating models only)
The air conditioner draws in heat
from the outdoor unit and releases
it via the indoor unit during heating
operation. When the outdoor
temperature falls, heat drawn in by the
air conditioner decreases accordingly.
At the same time, heat loading of
the air conditioner increases due to
larger difference between indoor and
outdoor temperature. If a comfortable
temperature can’t be achieved by the
air conditioner, we suggest you use a
supplementary heating device.
9. Auto-restart function
• Power failure during operation will
stop the unit completely.
• For the unit without Auto-restart
feature, when the power restores,
the OPERATION indicator on the
indoor unit will flash for 1second. To
restart the operation, push the ON/
OFF button on the remote controller.
For the unit with Auto-restart
feature, when the power restores,
the unit restarts automatically with
all the previous settings preserved
by the memory function.
15.
TROUBLESHOOTING
Trouble
OPERATION (RUN) indicator
or other indicators continue
flashing.
The unit may stop operation
or continue to run in a safety
condition(depending on models).
Waiting for about 10 minutes,
the fault may be recovered
automatically, if not, disconnect the
power and then connect it in again.
If the problem still exists, disconnect
the power and contact the nearest
customer service center.
If one of the following code
appears on the display area:
E1, E2, E4...En,
F1, F2, F3...Fn
Fuse blows frequently or
circuit breaker trips frequently. Stop the air conditioner
immediately, disconnect the power
and contact the nearest customer
service center.
Other objects or water fall into
the air conditioner.
Terrible odors are smelled or
abnormal sounds are heard.
SC code appears on the
display area.
It is normal. The unit is in X-fan
operation.
Malfunctions
Cause
What should be done?
Unit does not
start
Power cut
Wait for power to be restored.
Unit may have become
Unplugged.
Check that plug is securely in wall
receptacle.
Fuse may have blown.
Replace the fuse.
Battery in Remote controller
may have been exhausted.
Replace the battery.
The time you have set with
timer is incorrect.
Wait or cancel timer setting.
Содержание EPN09C38HW
Страница 112: ...www electrolux com shop 80327a ...