1
Gas connection point
2
Gasket
3
Adjustable connection
4
LPG rubber pipe holder
5
Natural gas pipe holder
Hob burners nozzles
Warning!
Before replacing the nozzles
ensure that the gas knobs are in OFF
position and disconnect the appliance
from the electrical supply.
Nozzles replacement
1. Remove the pan supports.
2. Extract the caps and the wall baffles of
the burners.
3. Using a socket spanner 7 unscrew and
remove the nozzles replacing them with
the ones required for the kind of gas in
use (see table " Burner characteristics " ).
4. Reassemble the parts following the same
procedure backwards.
5. Replace the rating label (placed near the
gas supply pipe) with the relevant one for
the new type of gas supply. You can find
this label in the package of the injectors
supplied with the appliance.
These burners do not need any primary air
regulation.
Adjustment of minimum level
To adjust the minimum level of the burners,
proceed as follows:
1. light the burner;
2. turn the knob on the position of minimum
flame;
3. remove the knob;
4. with a thin screwdriver, adjust the bypass
screw;
If changing from natural gas 20 mbar/13
mbar to liquid gas, completely tighten
the adjustment screw in, until a small
regular flame is obtained.
If changing from liquid gas to natural gas
20 mbar, undo the by-pass screw about
1/4 of a turn, until a small regular flame
is obtained.
If changing from natural gas 20 mbar to
natural gas 13 mbar undo the by-pass
screw about 1/4 of a turn, until a small
regular flame is obtained.
If changing from liquid gas to natural gas
13 mbar, undo the by-pass screw about
3/4 of a turn, until a small regular flame
is obtained.
Reassemble the parts following the same
procedure backwards.
Finally, check the flame does not go out
when quickly turning the knob from the max-
imum position to the minimum position.
electrolux
21