Fig. 8 B
GB
*
min. 180 cm.
min. 100cm
2
.
min. 180 cm.
min. 100cm
2
.
min. 100cm
2
.
GAS APPLIANCES
This appliance is not connected to a device to vent
the combustion products. It must therefore be
installed and connected in conformity with the
installation standards in force.
Particular attention must be paid to the standards
on ventilation of the room.
VENTILATION OF ROOMS
Remember that this appliance can be installed and
work in well-ventilated rooms only, according to the
standards in force, such as to allow, with openings
on the external walls or with special ducts, a correct
natural or forced ventilation
ensuring permanently
and sufficiently
both the entry of the air needed
for correct combustion and the removal of spent
air.
In particular when there is only this gas appliance
in the room, there must be a hood over the appliance
to ensure the natural and direct removal of spent
air, with a vertical straight duct of length equal to
at least twice the diameter and a minimum section
of at least 100 cm
2
.
For the indispensable entry of fresh air into the
room there must be a similar 100 cm
2
opening
directly to the outside, situated at a height near
floor level so that it is not blocked either inside or
outside the wall and so as not to cause disturbances
to correct burners combustion and to the regular
removal of spent air and with a difference of height
with respect to the outlet opening of at least 180
cm.
Remember that the quantity of air necessary for
combustion must never be less than 2m
3
/h for each
kW of power (see total power in kW on the appliance
data plate fig. 8B ).
In all other cases, i.e. when there are other gas
appliances in the same room, or when natural direct
ventilation is not possible and natural indirect or
forced ventilation must be installed, contact a
qualified specialist who will install and make the
ventilation system, scrupulously observing the
regulations contained in the standards in force.
The openings must be so positioned that there are
no draughts of air which cannot be tolerated by the
occupants.
Moreover to eliminate combustion products, it is
forbidden to use flues already used by other
appliances.
10
electrical fan
ROOMS VENTILATION
Содержание EKG 101199 X
Страница 1: ...Instructions booklet mod EKG 101199 X ...
Страница 16: ...L 2 1 3 4 5 N A H05 RR F H05 RN F 10 ...
Страница 17: ...C C C 9 FIG C FIG F C FIG F1 FIG G ...
Страница 18: ...8 A ...
Страница 19: ...1000 600 960 900 min 100cm2 C 7 REG MAX 15mm C ...
Страница 20: ...B A C L F R P G 6 5 1 0 15 2 0 2 5 30 3 5 4 0 45 5 0 55 ...
Страница 21: ...5 ...
Страница 22: ...4 1 4 0 17 0 250 2 1 0 ...
Страница 23: ...Ø Ø Ø Ø 3 1 1 2 2 4 4 5 5 6 6 7 7 8 8 9 9 3 3 6 7 8 9 10 ...
Страница 24: ... C 2 ...
Страница 25: ...Tip Montagnani Italy Cod 538515 0310 MADE IN ITALY ...