8
Sabbath Mode
Sabbath mode disables portions of
the unit and its controls in accordance
with the weekly Sabbath and religious
holidays observed within the Orthodox
Jewish community.
Sabbath mode is enabled and disabled by pressing
and holding the
vacation mode
key for five (5)
seconds and then releasing the key. Temperature
display shows “Sb” while in Sabbath mode.
The customer may open or close the door at any
time without concern of directly turning on or off
any lights, digital readouts, solenoids, fans, valves,
compressor, icons, tones or alarms. After power
failure, the unit will immediately return to Sabbath
mode.
While in Sabbath mode, alarm indicators will not
illuminate, nor be accompanied by audible alarms.
For further assistance, guidelines for proper usage
and a complete list of models with the Sabbath
feature, please visit the web at http:\\www.star-k.
org.
Operation
Alarms
door ajar
If the door has been left open for five
(5) minutes, an audible alarm will
sound and the
door ajar
indicator
will illuminate on the right side of the
display. The
mute sounds
indicator
will blink. Pressing and releasing the
mute sounds
key will acknowledge
the alarm and disable the audible por-
tion. The
door ajar
indicator will con-
tinue to blink until the door is closed.
high temp
In the event of a high temperature
condition, an audible alarm will sound,
the temperature display will blink and
display “HI”, and the
high temp
in-
dicator on the right side of the display
will blink. The
mute sounds
indica-
tor will blink. Pressing and releasing
the
mute sounds
key will acknowl-
edge the alarm and disable the audible
Description of Features
vacation mode
Conserves energy by disabling interior
lights and keypad inputs.
mute sounds
Tones emitted by each keypress can be
turned off based on user preference.
The sounds are muted when the red
indicator is lit. The
mute sounds
key also is used to acknowledge alarm
conditions, denoted by a flashing red
indicator. Press and hold the
mute
sounds
key for three (3) seconds
then release to enable
control lock
,
which prevents undesired changes to
the unit settings. Temperature display
will show “LOC”.
temperature
Simultaneously press and hold the (+)
and (–) keys for three (3) seconds then
releasing the key causes the tempera-
ture display to toggle from Fahrenheit
to Celsius and back again.
on off
Press and hold for three (3) seconds
then release the key. This allows the
user to turn off the cooling system.
The temperature display will display
“OFF”.
THIS DOES NOT REMOVE
POWER FROM THE UNIT
.
portion. All other modes are turned off
until the alarm is acknowledged. The
high temperature
indicator and “HI”
will stay illuminated until a normal safe
range operating temperature has been
reached, at which time the temperature
display will show the actual tempera-
ture.
power fail
In the event of a power failure or
initial power-up, an audible alarm will
sound and the
power fail
indicator
on the right side of the display will
blink. The
mute sounds
indicator
will blink. Pressing and releasing the
mute sounds
key will acknowledge
the alarm and disable the audible por-
tion. All other functions are disabled
until the alarm is acknowledged, at
which point the
power fail
indicator
is turned off and the unit will resume
normal operation. The
high temp
alarm may also be illuminated until a
safe temperature has been reached.
mode