27
- diameter and lenght of the tube in front
and behind the meter;
- section of transit of variuos tubes
positioned on the circuit;
- diameter of eventual connections.
IMPORTANT -
To ensure a correct
operation, a saving of energy and the long-
life of the appliance, the voltage pressure
of the appliance must correspond to the
recommended values.
The adjustable connection is fixed to the
comprehensive ramp by means of a
threaded nut G 1/2".
All the components shown in the diagram
have already been assembled in the factory.
The appliance, before leaving the factory,
has been tested in order to give you the
best results.
Connection
Carry out connection to the gas supply using
a rigid metal pipe with connections
conforming to the rules in force, or with a
flexible s/steel tube conforming to the
relevant rules in force, limited to those
whose max. length is 2 m. If flexible metal
tubes are used, make sure they do not
come into contact with mobile parts or are
crushed. Pay the same attention also when
an oven and top combination is provided for.
The appliance gas inlet connection is 1/2"
cylindrical threaded male. Carry out
connection avoiding any kind of stress to
the appliance.
IMPORTANT: After installation,
always check the perfect
tightness of all the connections,
using a soapy solution.
NEVER carry out this check with
a flame.
A)
Gas ramp end with nut
B)
Washer
C)
Elbow