– it can not get hot more than room tem-
perature, higher than 30°C;
– it is no longer than 1500 mm;
– it shows no throttles;
– it is not subject to traction or torsion;
– it does not get in touch with cutting
edges or corners;
– it can be easily examined in order to
check its condition.
The control of preservation of the flexible
pipe consists in checking that:
– it does not show cracks, cuts, marks of
burnings on the two ends and on its full
length;
– the material is not hardened, but shows
its correct elasticity;
– the fastening clamps are not rusted;
– expired term is not due.
If one or more defects are visible, do not re-
pair the pipe, but replace it.
Important!
When installation is complete,
make sure that the seal of each pipe fitting
is correct. Use a soapy solution,
not a
flame
!
Injectors replacement
1. Remove the pan supports.
2. Remove the caps and crowns of the
burner.
3. With a socket spanner 7 remove the in-
jectors and replace them with the ones
which are necessary for the type of gas
you use (see table in Technical Data
section).
4. Assemble the parts, follow the same
procedure backwards.
5. Replace the rating plate (it is near the
gas supply pipe) with the one for the
new type of gas supply. You can find
this plate in the package supplied with
the appliance.
If the supply gas pressure is changeable or
different from the necessary pressure, you
must fit an applicable pressure adjuster on
the gas supply pipe.
Adjustment of minimum level
To adjust the minimum level of the burners:
1. Light the burner.
2. Turn the knob on the minimum posi-
tion.
3. Remove the control knob.
4. With a thin screwdriver, adjust the by-
pass screw position.
1
1
The by-pass screw
– If you change from natural gas 20
mbar (or natural gas 13 mbar
1)
) to
liquid gas, fully tighten the by-pass
screw in.
– If you change from liquid gas to natu-
ral gas 20 mbar, undo the by-pass
screw approximately 1/4 of a turn.
– If you change from natural gas 20
mbar to natural gas 13 mbar
1)
undo
the by-pass screw about 1/4 of a
turn.
– If you change from liquid gas to natu-
ral gas 13 mbar
1)
, undo the by-pass
screw about 1/2 of a turn.
– If you change from natural gas 13
mbar
1)
to natural gas 20 mbar to
tighten the by-pass screw about 1/4
of a turn.
Warning!
Make sure the flame does
not go out when you quickly turn the
knob from the maximum position to the
minimum position.
Electrical connection
• Ground the appliance according to safety
precautions.
• Make sure that the rated voltage and
type of power on the rating plate agree
with the voltage and the power of the lo-
cal power supply.
• This appliance is supplied with a mains
cable. It has to be supplied with a correct
plug, able to support the load marked on
the rating plate. The plug has to be fitted
in a correct socket.
1) only for Russia