8.2
Built-in hobs
Only use the built-in hobs after you
assemble the hob into correct built-in units
and work surfaces that align to the
standards.
8.3
Connection cable
• The hob is supplied with the
connection cable.
• Replace the damaged mains cable only
with the spare parts cable. Speak to
your local Authorised Service Center.
WARNING!
All electrical connections must
be made by a qualified
electrician.
CAUTION!
Do not drill or solder the wire
ends. This is strictly forbidden!
CAUTION!
Do not connect the cable
without cable end sleeve.
Two-phase connection
1.
Remove the cable end sleeve from
black and brown wires.
2.
Remove an insulation of the brown
and black cable ends.
3.
Apply a new wire end sleeve of 1.5
mm² on each cable end. (special tool
required).
Cable cross section
N
L1
N
L
230V~
400V 2~N
L2
One-phase connection - 230 V~
Two-phase connection - 400 V 2 ~ N
Green - yellow
Green - yellow
N
Blue and grey
Blue and grey
N
L
Black and brown
Black
L1
Brown
L2
www.electrolux.com