electrolux
39
Remplacement of the voltage
Remplacement of the voltage
Remplacement of the voltage
Remplacement of the voltage
Remplacement of the voltage
cable
cable
cable
cable
cable
The connection of the voltage cable
to the appliance's terminal block is of
type "Y". This means that its
replacement requires the specific
equipment of a technician. In this case,
only cable type H05V2V2-F T90 must
be used. The cable section must be
suitable to the voltage and the working
temperature. The yellow/green earth
wire must be approximately 2 cm.
longer than the phase wires (Fig. 3-a).
To open the terminal block and
reach the terminals, proceed as
follows:
"
insert the point of a screwdriver into
the visible protrunding part of the
terminal block;
"
exert a light pressure and lift (Fig. 3-
b)
Fig. 3-b
Earth
(yellow/green))
Neutral
Fig. 3-a
Содержание EHG 6423
Страница 22: ...46 electrolux ...
Страница 23: ...electrolux 47 ...