4. Technical Data

Gas Burners Rating

Rapid Burner (big)

3 kW (G20) - 2,8 kW (G30/31)

Auxiliary Burner (small)

1  kW

Category

II 2H3+

Setting

Natural Gas G 20 - 20 mbar

Gas connection

G 1/2"

Electric Supply

230 V  50 Hz

HOB RECESS DIMENSIONS

Length

270 mm

Width

490 mm

2. Cleaning and Maintenance

• Disconnect the appliance from the electrical

supply, before carrying out any cleaning or
manteinance work.

Wash the enamelled components with warm soapy
water. Never use abrasive cleaners
Frequently wash the "caps" and the "crowns" with hot
soapy water, carefully taking away any built-up of food.
Carefully wash the stainless steel components with
water, then wipe them dry with a soft cloth.
The pan supports are dishwasher proof.
If the marks are particularly difficult to remove, use
common non-abrasive cleaners or specific products.
Never use steel wool pads or acids.
In models provided with electric ignition, this feature
is obtained through a ceramic "candle" and a metal
electrode (Fig. 1 - lett. C). Keep these components well
clean, to avoid difficult lighting, and check that the
burner crown holes (Fig. 1 - lett. B) are not obstructed.

PERIODIC MAINTENANCE

Periodically ask your local Service Centre to check the
conditions of the gas supply pipe and the pressure
adjuster, if fitted.
To ensure the good operation of the hob and its safety
features, it is necessary that the taps are periodically
lubricated.

z

z

z

z

z

The periodic lubrication of the taps must be
carried out by qualified personnel, which you
must refer to also in case of malfunctioning.

Fig.  2

FO 2110

This machine, before leaving the factory, has been
tested and studied by many experts and specialists, in
order to give you the best results.
Any repair work which needs to be carried out should be
done with the utmost care and attention.
For this reason we recommend that for any problem you
contact the dealer who sold it to you, or our nearest
authorized Service Centre, specifying the nature of the
problem, the appliance model (

Mod.

), the product

number (

Prod. No.

) and the serial number (

Ser. No.

)

marked on the identification plate.

3. Service and original spare parts

Original spareparts, certified by the product
manufacturer and carrying this symbol are only available
at our Service Centre and authorized spareparts shops.

Содержание EHG 3760

Страница 1: ...CZ HR SK RO SI Gas hob Gazovaà varoqnaà poverxnostì INSTRUCTION BOOKLET RUKOVODSTVO PO éKSPLUATACII 35686 9001 Mod EHG 3760 ...

Страница 2: ...sequent modifications During Operation About Installation Cleaning and Manteinance It is mandatory that all operations required for the installationarecarriedoutbyaqualifiedorcompetent person in accordance with existing rules and regulations Disconnect the appliance from the electrical supply before carrying out any cleaning or manteinance work Ensure a good ventilation around the appliance A poor...

Страница 3: ...urn the flame down or put it out before taking the pans off the burner USING THE HOB CORRECTLY To ensure maximum burner efficiency it is strongly recommended that you use only pots and pans with a bottom fitting the size of the burner used so that flame will not spread beyond the bottom of the vessel see the tablebeside It is also advisable as soon as a liquid starts boiling to turn down the flame...

Страница 4: ...ighting and check that the burner crown holes Fig 1 lett B are not obstructed PERIODIC MAINTENANCE Periodically ask your local Service Centre to check the conditions of the gas supply pipe and the pressure adjuster if fitted To ensure the good operation of the hob and its safety features it is necessary that the taps are periodically lubricated z z z z z The periodic lubrication of the taps must b...

Страница 5: ...pressure of the appliance must correspond to the recommendedvalues Theadjustableconnectionisfixedtothecomprehensive ramp by means of a threaded nut G 1 2 Interpose the sealing between the components as shown in Fig 3 Screw the parts without forcing adjust the connection in the required direction and tighten everything The adjustable connection allows the feeding pipe to be situated in the site pur...

Страница 6: ...n the appliance and the electricity supply withaminimumgapof3mmbetweentheswitchcontacts andofatypesuitablefortherequiredloadincompliance with the current rules The connection cable has to be placed in order that in each part it cannot reach a temperature 90 C higher than the room temperature The brown coloured phase cable fitted in the terminal blockcontactmarkedwith L mustalwaysbeconnected to the...

Страница 7: ...of gas Fig 7 FO 0392 ADJUSTMENT OF MINIMUM LEVEL To adjust the minimum level of the burners proceed as follows Light the burner Turn the knob on the minimum position Removetheknob Withathinscrewdriver adjusttheby passscrew see Fig 8 IfchangingfromnaturalgastoLPG completely tighten clockwise the screw until a small regular flame is obtained Finally check the flame does not go out when quickly turni...

Страница 8: ...t overlapping place the hob in the cut out taking care of its centring fix the hob with the relevant screws Fig 11 The traction of the screws is able to trace the sealing any excess of which can then be easily removed The edge of the hob forms a double labyrinth seal which provides a total guarantee against infiltration of liquids If several function are to be combined 2 burners hob fish kettle bu...

Страница 9: ...hob recess dimensions must comply with the indication given in Fig 10 and must be provided with openings to allow a continuous supply of air To avoid overhating the building in should be carried out as shown in Figs 13 and 14 The hob s electric connection and the oven s one must be carried out separately both for safety reasons and to allow the oven to be easily taken off the unit Hanging fornitur...

Отзывы: