![Electrolux EHE 64 Скачать руководство пользователя страница 6](http://html.mh-extra.com/html/electrolux/ehe-64/ehe-64_instruction-booklet_94538006.webp)
6
Instructions for the Installer
Supply connections
Electric:
230-240V 50Hz AC electrical supply
Engineers technical data
Overall dimensions
Width:
580 mm.
Depth:
500 mm.
Cut out dimensions
Width:
550 mm.
Depth:
470 mm.
Heating elements Ratings
Normal back left Hotplate Ø 145 mm
1045 W
Normal back right Hotplate Ø 180 mm
1570 W
Rapid front right Hotplate Ø 145 mm
1570 W
Rapid front left Hotplate Ø 180 mm
2090 W
Total rating
6.7 kW
700 mm
400 mm
100 mm
400 mm
50 mm
55 mm
50 mm
INSTALLATION GUIDANCE INSTRUCTIONS
CLEARANCES REQUIRED
WHEN FITTING THE HOB
WITHOUT A COOKER HOOD ABOVE
INSTALLATION GUIDANCE INSTRUCTIONS
CLEARANCES REQUIRED
WHEN FITTING THE HOB
WITH A COOKER HOOD ABOVE
FO 0813
FO 0812
Important safety requirements
This hob must be installed by qualified personnel,
according to the manufacturer’s instructions and to the
relevant Australian Standards.
Location
This hob has been registered as a "Class X" appliance
according to Fire Risk Regulations. Minimum distances
detailed below must be observed.
The hob may be located in a kitchen, a kitchen/diner or
bed sitting room, but not in a bathroom or shower room.
Before making the cut out in the worktop ensure that
there is a minimum distance of 55 mm. between the
rear edge of the hob and the wall. A minimum distance
of 100 mm. must be left between the side edges of the
hob and any adjacent cabinets or walls.
The minimum distance combustible material can be
fitted above the hob in line with the edges of the hob is
400 mm. If it is fitted below 400 mm. a space of 50
mm. must be allowed from the edges of the hob.
The minimum distance combustible material can be
fitted directly above the hob is 700 mm.
650 mm
400 mm
400 mm
100 mm
50 mm
50 mm
55 mm
600 mm
700 mm