Instruction for the Installer

The following instructions about installation
and maintenance must be carried out by
qualified personnel in compliance with the
regulation in force.

The appliance must be electrically
disconnected before all interventions. If any
electric supply to the appliance is required to
carry out the work, ensure all the necessary
precautions are followed.

The side walls of the unit in which the hob is
going to be installed, must not exceed the
height of the working top.

Avoid installing the appliance in the proximity
of inflammable materials (e.g. curtains, tea
towels etc.).

The appliance is designed to be connected to 230 V
monophase electricity supply.
The connection must be carried out in compliance with
the laws and regulations in force.
Before the appliance is connected:

1. check that the main fuse and the domestic installation

can support the load (see the rating label);

2. check that the power supply is properly earthed in

compliance with the current rules;

3. check the socket or the double pole switch used for

the electrical connection can be easily reached with
the appliance built in the forniture unit.

The appliance is supplied with a connection cable. This
has to be provided with a proper plug, able to support the
load marked on the identification plate. To connect the
plug to the cable, follow the recommendation given in
Fig.1. The plug has to be fitted in a proper socket.
If connecting the appliance directly to the electric system,
it is necessary that you install a double pole switch
between the appliance and the electricity supply, with a
minimum gap of 3 mm. between the switch contacts and
of a type suitable for the required load in compliance with
the current rules.
The connection cable has to be placed in order that, in
each part, it cannot reach a temperature 90 °C higher than
the room temperature.
The brown coloured phase cable (fitted in the terminal
block contact marked with "L") must always be connected
to the network phase.

Electrical Connection

Fig. 1

Neutral

Earth (yellow/green)

Replacement of the connection cable

The replacement of the connection cable requires the
specific equipment of a technician.

In this case, only cable type H05V2V2-F T90 must be
used. The cable section must be suitable to the voltage
and the working temperature.
The yellow/green earth wire must be approximately 2
cm longer than the phase wires (Fig. 1).

Содержание EHC 320

Страница 1: ...Built in Hob Encimera Placa de encastrar Mod EHC 320 INSTRUCTION BOOKLET MANUAL DE INSTRUCCIONES INSTRUÇÕES DE UTILIZAÇÃO 35689 5501 CZ HU HR SL SK RO PL ES PT ...

Страница 2: ...ce is out of order disconnect it from the electric supply About Installation Cleaning and Manteinance It is mandatory that all operations required for the installationarecarriedoutbyaqualifiedorcompetent person in accordance with existing rules and regulations Disconnect the appliance from the electrical supply beforecarryingoutanycleaningormanteinancework ENGLISH For Your Safety These warnings ar...

Страница 3: ...trol knob for the rear cooking zone 5 Control knob for the front cooking zone How To Use Setting 1 Keeping warm Setting 2 Gentle simmering Setting 3 Simmering Setting 4 Frying browning Setting 5 Bringing to the boil Setting 6 Bringing to the boil quick frying deep frying Pilotlight Pilot light is activated when either of the zones are turned on and will remain on until the cooking zones are switch...

Страница 4: ...uantities Ifthediameterofthebaseistoo small the energy consumption will increase and any food boiling over will burn onto the hot cooking zone Saucepans with very shiny bright bases will prolong the cooking time slightly compared with cooking utensils with matt dark bases Use a tightly fitting lid on the saucepan Without a lid you use more than three times as much electricity Do not slide saucepan...

Страница 5: ...reases the heat transfer between cooking zones and cookware After use the cooking zones should be wiped with a damp cloth with washing up liquid For severe soiling you can follow these steps 1 Remove stains etc with a proper ceramic hob scraper 2 Make sure that the ceramic hob has cooled down Use a proper ceramic cleaning agent 3 Wipe the ceramic hob clean with a damp cloth or kitchen roll Tough s...

Страница 6: ...e easily reached with the appliance built in the forniture unit The appliance is supplied with a connection cable This hastobeprovidedwithaproperplug abletosupportthe load marked on the identification plate To connect the plug to the cable follow the recommendation given in Fig 1 The plug has to be fitted in a proper socket Ifconnectingtheappliancedirectlytotheelectricsystem it is necessary that y...

Страница 7: ...50 mm minimum from the hob Carry out the building in of the hob as follows 1 Place the sealing gasket Fig 4 A all around the edge of the cut out 2 Fit the hob in the cut out and push it down until it comes in contact with the kitchen top surface Then remove the excess sealing 3 Toremovethehobfromthecut out lifttheedgeofthe hob by means of the edge of a screw driver If several 30cm hob are to be in...

Страница 8: ... if technical assistance is needed The space behind the kitchen unit b can be used for connections Kitchen unit with oven The hob recess dimensions must comply the indication given in Fig 3 and the kitchen unit must be provided with proper openings to allow a continuous supply of air Suggestions to ensure a proper ventilation are shown in Figs 6 e 7 The electrical connection for the hob must be se...

Отзывы: