background image

 

 

7. CONVERSION DETAILS 

 

The appliance is convertible between Natural Gas & LP. 

 

Procedure

 

                                 

1.

 

Turn off gas supply to appliance.  

2.

 

Disconnect appliance from electrical power. 

3.

 

Remove the trivets and the burner caps & distributors. 

4.

 

Remove the existing injectors and replace with the injectors shown in the table below.  

5.

 

Remove the control knobs to access the by-pass screw in the valve bodies. 

6.

 

Remove the regulator and replace with appropriate regulator or test point adapter as stated in 

table below, and reconnect the appliance. 

7.

 

Turn on gas & check for leaks. Replace the Burner crowns & caps. 

8.

 

Check  and  adjust  the  test  point  pressure  according  to  the  procedure  in  the  installation 

instructions. 

9.

 

Manually light all burners with a hand held ignition source and operate burners at maximum. 

Note: Do not reconnect the appliance to electrical power until this procedure is complete

10.

 

For each hotplate burner adjust the burner to minimum and screw in the bypass screw until a 

small  stable  flame  results.  Adjust  the  burner  to  maximum  and  back  to  minimum  to  ensure 

correct adjustment. 

11.

 

Re-connect to electrical power and check ignition. 

 

 

 

Содержание EGT 9425K

Страница 1: ...SERVICE MANUAL ...

Страница 2: ...OTES 2 2 HOW DOES GAS BURNER OPERATE 3 3 COMPONENTS SPECIFICATION 4 4 TOOLS 6 5 REPAIR PROCESS 6 Remove the dirty oil from nozzle Remove the gas valve 6 WIRING DIAGRAM 8 7 CONVERSION DETAILS 9 8 SPARE PARTS 11 9 TROUBLE SHOOTING 17 ...

Страница 3: ...n be located with soap and water applied at the connection 4 Burner supply pipes leading from the burner control to the burner should have their compression fittings tightened firmly but not over tightened If a torque spanner is used set this to 10 12Nm If the tubes are damaged they should be replaced The soundness of the connections on the burner supply tubes can be tested by blocking the injecto...

Страница 4: ... gas with fibre washer Warning Do not use regular rubber washer 5 2 steps safety valve 6 Burner 7 Ignition switch 8 Battery 1 5V size D 9 Spark generator 10 Spark plug Gas from the tank 1 is released from the low pressure regulator 2 into the hose or tube 3 travelling pass the elbow coupling to the valve 4 To ignite the burner press down and turn the 1 2 3 4 5 6 7 8 9 10 ...

Страница 5: ...cally supplied from the battery to spark plug generator 8 and then to the pin heads 9 causing the ignition 10 The burner is ignited and bursts into flame 11 3 COMPONENTS SPECIFICATION Glass 3B Float glass 8 0x460x760 mm Bottom plate forming Zinc coat Knob heat flame resistance Washer fiber Hose end Brass size1 2A Rubber grommet glass model Silicone heat resistance Spark generator 4p 1 5Vdc 90C ele...

Страница 6: ...tion Semi Papid TH 0003 ZA Shutter Altration Triple Crown TH 0003 ZB Injector 2 1 Semi Rapid TH 0003 CD Injector 4 0 Triple Crown TH 0003 ZA Screw M4x0 7x10 IP Screw M4x0 7x18 H Screw M3x12T B stainless Screw 6 32 x 9 PPZF Screw 8 x T Z ...

Страница 7: ...ean 5 2 Removal of Hob Access to Internal Components 1 Isolate the appliance from battery power 2 Remove trivets and burners from hob 3 Remove the control knobs from the valve shafts 4 Remove burner mount retaining screws 2 screws per burner and 4 on the wok burner 2 5mm Torque Screwdriver required 5 For models with a separate button ignition system remove the switch button and ignition pack retai...

Страница 8: ...late and disconnect the appliance from gas supply Switch harness assembly and low voltage wiring Ignition spark plug and lead assemblies These are fastened to the burner bases by retaining clips located on the underside of the burner base Ignition pack For models without a separate ignition switch this is clipped to the base or attached with double sided adhesive For models with a separate ignitio...

Страница 9: ...8 6 WIRING DIAGRAM ...

Страница 10: ...adapter as stated in table below and reconnect the appliance 7 Turn on gas check for leaks Replace the Burner crowns caps 8 Check and adjust the test point pressure according to the procedure in the installation instructions 9 Manually light all burners with a hand held ignition source and operate burners at maximum Note Do not reconnect the appliance to electrical power until this procedure is co...

Страница 11: ...sh abrasive cleaner powder cleaner steel wool or wax polishes should not be used Advise end user do not use glass as per working top Models With Standard Valves No Flame Failure Safety Devices LPG 30 0 mbar City gas 8 0 mbar Natural Gas 20 0 mbar BURBERS Injector size Rating KW Injector size Rating KW Injector size Rating KW Triple crown 0 98 4 0 4 00 4 5 1 5 4 0 Semi rapid 0 71 2 0 2 10 2 0 0 96 ...

Страница 12: ...11 8 SPARE PARTS ...

Страница 13: ... 006 2 18 TH 0005 AI KP H III B100 3 DIAM 7MM CONNECTOR 2 19 TH 0004 VR ALUM PIPE LZO 2BG ETU90 1 20 TH 0004 XR ALUM PIPE RZO 2BG ETU90 1 21 TH 0005 ZD SPARKER FOR TRIPLE FRAME GLAZE 2 22 TH 0005 WB GENERATOR 2P SABAF DC 1 23 TH 0005 VA BATTERY BOX 1 24 H3 0013 AA BATTERY D 1 25 H6 0041 AA CABLE TIE CV 100 2 26 TH 0005 ZZ SPARKER CLIP 4 27 TH 0015 AE GASKET OD 18 4 X ID 12MM 2 28 OT 0002 AA SCREW ...

Страница 14: ...OLE 1 48 TH 0027 FW PACKING STICKER EGG9425K LPG 2 49 TH 0027 GW RATING LABEL EGG9425K LPG 1 50 TH 0028 AA GAS TYPE LABEL LPG ZANUSSI 1 51 RH 0019 CA MIRAMET SHEET 600 X 1000MM 1 52 RH 0013 AA ELBOW 376003300 1 53 H2 0202 CD GUARANTEE CARD ELECTROLUX 1 CITY GAS ACCESSORIES 52 TH 0003 CC INJECTOR 4 0 TRIPLE CROWN 2 53 TH 0003 ZB SHUTTER AERATION TRIPLE CROWN 2 ...

Страница 15: ...14 ...

Страница 16: ... 0 71 INJEC 1 17 TH 0015 AE GASKET OD 18 4 X ID 12MM 1 18 TH 0004 BY I PIPE 3B ETU90 1 19 TH 0006 ZJ BURNER CAP SEMI RAPID MATT 1 20 TH 0005 RA IGNITION VALVE BRACKET THH 006 3 21 TH 0016 BW KNOB ETU PART 305449901 3 22 TH 0016 CA KNOB GASKET 3 23 TH 0006 ZE BURNER CROWN SEMI RAPID CYCLIN 1 24 TH 0005 ZE SPARKER FOR SEMI RAPID GLAZED 1 25 TH 0005 AI KP H IIIB 100 3 3 26 TH 0004 VS ALUM PIPE LZO 3B...

Страница 17: ...C 90 ETU POWER 2 54 TH 0020 AJ CUT OUT DIE CUT PAD ETU 90 1 55 TH 0021 FF HOB LINER ELUX NO MODEL ETU 90 1 56 TH 0022 EE INST MANUAL ETU POWER GL 1 57 TH 0023 BD REGULATOR STICKER 1 58 RH 0019 AB EPS FRONT BACK KATA NICOLE 1 59 TH 0027 FY PACKING STICKER EGT 9435K 2 60 TH 0027 GY RATING LABEL EGT 9435K 1 61 TH 0028 AA GAS TYPE LABEL LPG 1 62 H2 0202 CD GUARANTEE CARD ELECTROLUX 1 63 RH 0019 CA MIR...

Страница 18: ...nsure that crown is seated property so that the spark fires to the receiving point in burner crown No spark is obtained when the control knob is activated Battery is flat Polarity wrong on battery Ignition electrode wet or dry Replace battery Re orient battery to correct position Dry or clean ignition electrode Flame ports blocked or wet Clean or dry frame ports Flames uneven or tending to lift Bu...