When you assemble each
burner, use the special cap
tool (C) and a screwdriver to
prevent damage to the nuts.
A
B1
B2
C
1. Auxiliary: screw on the nuts with the
diameter of 10 mm (B1), included in
the supply (primary air regulators).
2. Rapid burner: screw on the nuts with
the diameter of 16 mm (B2), included
in the supply (primary air regulators).
Be sure to remove the cap
tool before reassembling the
burners.
3.5 Adjustment of minimum
level
To adjust the minimum level of the
burners:
1. Light the burner.
2. Turn the knob on the minimum
position.
3. Remove the knob.
4. With a thin screwdriver, adjust the
bypass screw position (A).
A
5. If you change:
• from liquid gas to town gas G110
14mbar, undo the bypass screw
approximately 1 turn.
• from town gas G110 14 mbar to
liquid gas, fully tighten the bypass
screw in.
WARNING!
Make sure the flame does
not go out when you quickly
turn the knob from the
maximum position to the
minimum position.
3.6 Replacing the power supply
cable
Use the same type of power supply
cable. This cable must be connected to
the terminal block following the diagram.
2
3
0
V~
230V~
N
PE
L
If the power supply is
damaged it must be
substituted by a suitable
cable available in the after
sales service.
ENGLISH