background image

37

Fig. 11

A

B

C

Fig. 10

Mounting the cold air valve (Fig. 10):

Not applicable for recirculation. The cold air valve

consists of a damper seat with two valves, which shall

be fitted into the hood outlet. If there is no other form

of ventilation to expel air from the kitchen than the

hood, the outer end of the valves should be clipped off

and removed. Insert a pen or something similar

between the valves. These should open up easily now.

Mounting the venting kit (Fig. 11):

Not applicable for recirculation. A complete venting

kit is available as an optional extra. The ventilation

pipe (A) is pulled over the hood’s evacuation flange

(B) and is held firmly in place with a clamp. Make sure

the pipe is as straight as possible and does not hinder

the movement of the valve flaps. The pipe is connected

to the mouth of the duct with the metal flange (C)

which is included in the kit.

Fitting the carbon filter

Only applicable for recirculation. The LONG LIFE

carbon filter (special accessory) for this hood is fitted

instead of the grease filter. The LONG LIFE carbon

filter is both a grease and carbon filter for reduction of

cooking smells.

An opening must be made at the top or front of the

cupboard (min. 100 cm²) where the hood is fitted, so

the cleaned air can freely circulate back into the

kitchen.

Extend the duct hose correctly. A duct

hose which is too long or has too many

bends can reduce cooker hood efficiency

by fifty per cent. Shorten the hose if it is

too long, and avoid unnecessary bends in

it.

B

A

C

Содержание EFT 540

Страница 1: ...821 27 91 01 1 Cooker Hood EFT 540 EFT 640 EFT 740 USER MANUAL ...

Страница 2: ...epærer Livstiden for lavenergilysstofrør svarer til livstiden for 8 stk glødetrådspærer Energiansäästölamppu vastaa kestoiältään kahdeksaa 8 hehkulamppua Fabriken källsorterar Plåt wellpapp trä papper och cellplast Fabrikken kildesorterer sitt avfall Stål tre papir papp og plast Fabrikken sorterer affald Metal pap træ papir og plast Tehdas kierrättää Pellit pakkausmateriaalin puun paperin ja muovi...

Страница 3: ...person can lead to loss of function of the cooker hood and possible damage to person and or property The cooker hood must be at least 40 cm above electric burners or electric range The cooker hood is not approved for mounting above gas burners or gas range Ensure that the power cord does not get squeezed at the installation The cooker hood is only currentless when the plug or the fuse is disconnec...

Страница 4: ...ashers 4 pcs M5 mm nuts 4 pcs spacers 4 pcs 10 mm wall dowels 4 pcs locknuts 4 pcs plastic covers 2 pcs brackets Cold air valve Instruction book Following is ordered from retailer Venting kit When the cooker hood is to be connected to an evacuation channel use the venting kit containing one ventilation pipe one roof connecting metal flange and two clamps PNC 391 414 201 LONG LIFE carbon filter The...

Страница 5: ... a higher speed than necessary The low speeds are adequate for ordinary requirements while cooking The high speeds should be used only if food has burnt while cooking or for other strong fumes Cleaning the hood Clean the outside of the hood using a damp cloth and a mild detergent Never use corrosive abrasive or flammable cleaning products Clean the filter regularly The grease that collects in the ...

Страница 6: ...instructions The filter should be changed after about 3 years as its ability to absorb smells has reduced by then The filter insert is removed from the frame and is replaced with a new one according to the filter instructions Before calling for service Check the plug is correctly connected to the wall socket Check the fuse Do not attempt any repairs yourself that are likely to lead to further dama...

Страница 7: ...hould immediately be reported to the transport company Damages faults and eventually missing parts should immediately be reported to the retailer Dispose carefully of the packaging material so that it is out of the way of small children Remove the transport supports C Fig 9 Position The cooker hood should be mounted freely hanging on the wall The cooker hood must be at least 40 cm above electric b...

Страница 8: ... be drilled on the wall Drill in the markings with an Ø8 mm drill and fit rawl plugs into the holes Use the template printed on the packaging Fix the screws A Leave about 5 mm distance between the screws and the wall Hook the cooker hood on the screws A Remove the grease filter and mount the screws B in the two lower holes Remove the grease filter by pulling it backwards against the wall and then ...

Страница 9: ...n place with a clamp Make sure the pipe is as straight as possible and does not hinder the movement of the valve flaps The pipe is connected to the mouth of the duct with the metal flange C which is included in the kit Fitting the carbon filter Only applicable for recirculation The LONG LIFE carbon filter special accessory for this hood is fitted instead of the grease filter The LONG LIFE carbon f...

Страница 10: ... 1998 MO STF ...