22
Mounting under cupboard
●
Make the holes on the bottom of the cupboard,
using the drilling template (Fig. 7).
●
From inside the cupboard, insert the 4 supplied
screws and tighten them in the appropriate holes
on the appliance.
Exhausting mode
●
Connect the air outlet to the smoke exhaust hose
●
Open the suction grid (Fig. 12).
●
Check that the selection lever for evacuation/
recycle is in the position A - external evacua-
tion. (Fig. 8).
●
Refit the suction grid.
Recirculation mode (with carbon
filter)
The air outlets D (Fig. 2) must be shut with plug H.
●
Open the suction grid (Fig. 12).
●
Check that the selection lever for evacuation/
recycle is in the position : F - recycle (Fig. 8)
●
Place the carbon filter so to cover the fan
housing.
The plastic reference on carbon filter must
match the arrow printed on the fan housing.
Rotate clockwise until stop (Fig. 9).
●
Refit the suction grid.
Using the hood
The control panel is located on the front part of the
hood.
Speed regulation
The hood has a three speed motor regulated with a
slide switch. For the best performance, we recom-
mend using the highest speed in particular cases of
strong odour and vapour concentration.
We recommend starting up the hood a few minutes
before cooking and keeping it running until all the
odours have been eliminated.
Fig. 7
Fig. 8
Fig. 10
2
1
3
4
2
1
3
4
3,5 x 35
F
A
0 1 2 3
0 I
Fig. 9