background image

5

F

Unpacking

Check that the cooker hood has no damages.
Transportation damages should immediately be
reported to the one responsible for the transport
Damages, faults and eventually missing details
should immediately be reported to the seller.
Take care of the packing material so that small
children cannot play with it.

Placement

The hood is to be mounted in a wall cupboard.
When installed, the hood must be not less than 65
cm. above electric burners or 75 cm. above gas or
mixed-fuel burners. (Fig. 3).

Electrical connection

The hood has a power cord with moulded plug
with earth connection to be connected to a wall
outlet of 230 V.
The power cord length is 1,25 m.

Mounting under wall cabinet

Drill holes on the bottom of the cupboard as
shown in the supplied drilling diagram (Fig. 4),
do not consider the thickness of the front panel
of the cupboard.

From inside the cupboard, insert the four 4.2x35
screws C (Fig.5) supplied with the unit and
screw them onto nuts F (Fig.5).

By means of the appropriate screws, fit the
angle iron E (Fig.6) so that it is tightly fixed to
the wall.

Make an hole on the top of the cupboard for the
passage of the discharge (see  the drilling
diagram for diameter).

Installation

Special accessories

Active carbon filter

When the hood is used in recirculation mode an
active carbon filter should be used.
Order by the retailer
PNC 955 101 117

Fig. 6

Min

65 cm

Min

75 cm

Fig. 3

Fig. 4

Fig. 5

C

C

C

C

F

F

F

E

Содержание EFP 629

Страница 1: ...User Manual EFP 629 UK ...

Страница 2: ...cking 5 Placement 5 Electrical connection 5 Mounting under wall cabinet 5 Exhausting mode 6 Recirculation mode with carbon filter 6 Using the hood 6 Speed regulation 6 Work light 6 Correct ventilation 6 Maintenance 7 Grease filter 7 Carbon filter 7 Cleaning 7 Changing the lighting elements 7 If the hood does not function 8 Technical data 9 ...

Страница 3: ...roperties The hood cannot be connected to flues of other appliances that run on energy sources other than electricity Please keep to the provisions of official direc tives regarding the question of fumes discharge When the hood is used at the same time of other appliances that run on energy sources other than electricity provision must be made for an adequate supply of air When installed the hood ...

Страница 4: ...anted about 10 and directed upwards to vent the air easily from the room to the outside The hood cannot be connected to flues of other appliances that run on energy sources other than electricity Please keep to the provisions of official directives regarding the question of fumes discharge Recycling The air is filtered through a carbon filter and recirculated into the room The filtered air is disc...

Страница 5: ...a wall outlet of 230 V The power cord length is 1 25 m Mounting under wall cabinet Drill holes on the bottom of the cupboard as shown in the supplied drilling diagram Fig 4 do not consider the thickness of the front panel of the cupboard From inside the cupboard insert the four 4 2x35 screws C Fig 5 supplied with the unit and screw them onto nuts F Fig 5 By means of the appropriate screws fit the ...

Страница 6: ...r and vapour concentration Speed can be switched ON and OFF opening or closing the extractible drawing We recommend starting up the hood a few minutes before cooking and keeping it running until all the odours have been eliminated The hood is equipped with a micro switch that activates the pre selected fan speed when the drawer is opened Work light The hood has two lamps 40 W E 14 Switch on and of...

Страница 7: ...seat Fig 9 Attention Failure to observe the rules for cleaning the appli ance and changing and cleaning the filters may cause fires Therefore we recommend observing these instructions Important to know If the hood is run at the same time as a burner or fireplace that depend on ambient air for example gas Diesel coal or wood heaters water heaters etc be careful because the hood when it exhausts the...

Страница 8: ...an approved service company Remember to save the purchase recite and the Warranty card only used in some countries Service and spare parts Service and spare parts you will get via your dealer or service company When you order service or spare parts you should be ready to give the product number and model denomination This information you will find on the rating label Take away the grease filter an...

Страница 9: ... Height 175 mm Width 598 mm Depth 300 mm Light 2 x 40 W E 14 Grease filter 1 pc Mains Voltage 230 V Electric safety class Class 1 Power rating total 220 W x Valid when the hood is used with carbon filter recirculation 598 44 44 24 20 200 280 10 20 135 40 78 17 5 138 17 5 Ø 99 28 224 28 ...

Страница 10: ...1007 AHS L 712 Ed 03 96 ...

Отзывы: