User Manual

EFC 9550

Содержание EFC 9550

Страница 1: ...User Manual EFC 9550 ...

Страница 2: ...e recommendations contained in this Instruction Manual your appliance will give you constant high performance and will remain efficient for many years to come RECOMMENDATIONS AND SUGGESTIONS 3 CHARACTERISTICS 4 INSTALLATION 6 USE 9 MAINTENANCE 10 ...

Страница 3: ...xhaust gas The kitchen must have an opening communicating directly with the open air in order to guarantee the entry of clean air USE The extractor hood has been designed exclusively for domestic use to eliminate kitchen smells Never use the hood for purposes other than for which it has ben designed Never leave high naked flames under the hood when it is in operation Adjust the flame intensity to ...

Страница 4: ...4 GB CHARACTERISTICS Dimensions 650 min 507 360 898 100 360 108 244 150 min 850 max 1145 740 260 300 63 90 132 433 60 ...

Страница 5: ... Outlet Grill 9 1 Reducer Flange ø 150 120 mm 14 1 Hood BodyAir Outlet Extension Piece consisting of two Half Shells 14 1 2 Air Outlet Connection Extension 15 1 Air Outlet Connection Ref Q ty Installation Components 7 2 1 2 Upper Chimney Section Fixing Brackets 11 6 Wall Plugs 12a 6 Screws 4 2 x 44 4 12c 4 Screws 2 9 x 9 5 Q ty Documentation 1 Instruction Manual 2 1 2 2 2 12c 12a 7 2 1 11 11 12a 1...

Страница 6: ...ll as shown at X mm below the first bracket X height of the upper chimney section supplied aligning the centre notch with the vertical line Mark the wall at the centres of the holes in the bracket Mark a reference point as indicated at 116 mm from the vertical reference line and 323 mm above the horizontal reference line Repeat this operation on the other side Drill ø 8 mm holes at all the centre ...

Страница 7: ...to level the hood body Connections DUCTED VERSION AIR EXHAUST SYSTEM When installing the ducted version connect the hood to the chimney using either a flexible or rigid pipe ø 150 or 120 mm the choice of which is left to the installer To install a ø 120 mm air exhaust connection insert the reducer flange 9 on the hood body outlet Fix the pipe in position using sufficient pipe clamps not supplied R...

Страница 8: ...wer outlet duct has been installed Ensure that the activated charcoal filters have been inserted ELECTRICAL CONNECTION Connect the hood to the mains through a two pole switch having a contact gap of at least 3 mm Flue assembly Upper exhaust flue Slightly widen the two sides of the upper flue and hook them behind the brackets 7 2 1 making sure that they are well seated Secure the sides to the brack...

Страница 9: ...off at low speed Used to provide a contin uos and silent air change in the presence of light cooking vapours V2 Speed Medium speed suitable for most operating conditions given the optimum treated air flox noise level ratio V3 Intensive Maximum speed used for eliminating the highest cooking vapour emission including long periods L V1 V2 V3 S ...

Страница 10: ...ING THE ACTIVATED CHARCOAL FILTER The filter is not washable and cannot be regenerated and must be replaced approximately every 4 months of operation or more frequently for particularly heavy usage Remove the metal grease filters Remove the saturated activated carbon filter by releasing the fixing hooks Fit the new filter by hooking it into its seating Replace the metal grease filters Lighting LIG...

Страница 11: ......

Страница 12: ...nce conforms to European Low Voltage Directive 73 23 CEE governing electrical safety European Directive 89 336 CEE on Electromagnetic Compatibility and Directive 93 68 CEE regarding CE Marking 436001716 01 030311 ...