MAINTENANCE

 

REMOTE CONTROL (OPTIONAL) 

The appliance can be controlled using a remote control 
powered by a 1.5 V carbon-zinc alkaline batteries of the 
standard LR03-AAA type. 
•  Do not place the remote control near to heat sources. 
• Used batteries must be disposed of in the proper 

manner. 

 

Grease filters 

CLEANING METAL SELF- SUPPORTING GREASE FIL-

TERS 

Alarm signal reset 

•  Switch off the lights and extractor motor. 
•  Press button 

T3

 for at least 3 seconds, until the leds 

start to flash. 

 
Cleaning the filters

 

•  The filters are washable and must be cleaned when 

the LED 

S1

 lights up or at least every 2 months of 

operation, or more frequently for particularly heavy 
usage. 

•  Remove the filters one at a time by pushing them to-

wards the back of the group and pulling down at the 
same time.  

•  Wash the filters, taking care not to bend them. Allow 

them to dry before refitting. 

•  When refitting the filters, make sure that the handle 

is visible on the outside. 

Содержание EFC 9541

Страница 1: ...EFC 9541 Instructions Manual Bedienungsanleitung ...

Страница 2: ...EN 2 2 Instructions Manual INDEX RECOMMENDATIONS AND SUGGESTIONS 4 CHARACTERISTICS 5 INSTALLATION 7 USE 10 MAINTENANCE 11 ...

Страница 3: ...DE 3 3 Bedienungsanleitung INHALTSVERZEICHNIS EMPFEHLUNGEN UND HINWEISE 13 CHARAKTERISTIKEN 14 MONTAGE 16 BEDIENUNG 19 WARTUNG 20 ...

Страница 4: ...gree of aeration must be guaranteed in the room in order to prevent the backflow of ex haust gas The kitchen must have an opening communicating directly with the open air in order to guarantee the entry of clean air USE The extractor hood has been designed exclusively for domestic use to eliminate kitchen smells Never use the hood for purposes other than for which it has ben designed Never leave h...

Страница 5: ...EN 5 5 CHARACTERISTICS Dimensions 650 min ...

Страница 6: ...wer frame 9 1 Reducer Flange ø 150 120 mm 10 1 Flange ø 150 15 1 Air Outlet Connection 24 1 Junction box 25 2 Pipe clamps Ref Q ty Installation Components 11 4 Wall Plugs ø 10 12c 6 Screws 2 9 x 6 5 12e 2 Screws 2 9 x 9 5 12f 4 Screws M6 x 10 12g 4 Screws M6 x 80 12h 4 Screws 5 2 x 70 21 1 Drilling template 22 4 6 4 mm int dia washers 23 4 M6 nuts Q ty Documentation 1 Instruction Manual 12c 7 1a 7...

Страница 7: ...ings with wall thickness of 20 mm drill ø 10 mm immediately insert the Dowels 11 supplied For wooden beam ceilings drill according to the wood screws used For wooden shelf drill ø 7 mm For the power supply cable feed drill ø 10 mm For the air outlet Ducted Version drill according to the diameter of the external air ex haust duct connection Insert two screws of the following type crossing them and ...

Страница 8: ...he frame by turning it Make sure that the screws do not come out of their seats in the slotted holes The frame mountings must be secure to withstand the weight of the hood and any stresses caused by the occasional side thrust applied to the device On completion check that the base is stable even if the frame is subjected to bending In all cases where the ceiling is not strong enough at the sus pen...

Страница 9: ...emove the grease filters from the hood body Remove any activated charcoal filters From below use the 4 screws 12f M6 x 10 provided to fix the hood body to the frame 12f 12c 12c ELECTRICAL CONNECTION Connect the hood to the mains through a two pole switch hav ing a contact gap of at least 3 mm Remove the grease filters see paragraph Maintenance being sure that the connector of the feeding cable is ...

Страница 10: ...n the button is pushed for about 2 seconds After 10 minutes of functioning it turns off automatically This function can be interrupted by means of pressing any of the buttons S1 Led Fixed Indicates that the Metal grease filters saturation alarm has been triggered and the filters need to be washed The alarm is triggered after 100 working hours Reset check the Maintenance paragraph Flashing indicate...

Страница 11: ...et Switch off the lights and extractor motor Press button T3 for at least 3 seconds until the leds start to flash Cleaning the filters The filters are washable and must be cleaned when the LED S1 lights up or at least every 2 months of operation or more frequently for particularly heavy usage Remove the filters one at a time by pushing them to wards the back of the group and pulling down at the sa...

Страница 12: ...tion LED flashes twice Activated charcoal filter saturation alarm ENABLED LED flashes once Activated charcoal filter saturation alarm DISABLED Replacing the activated charcoal filter Alarm signal reset Switch off the lights and extractor motor Press button T3 for at least 3 seconds until the leds start to flash Replacing the Filter Remove the metal grease filters Remove the saturated activated car...

Страница 13: ...t recycling of this product please contact your local city office your household waste disposal service or the shop where you purchased the product Das Symbol auf dem Produkt oder seiner Verpackung weist darauf hin dass dieses Produkt nicht als normaler Haushaltsabfall zu behandeln ist sondern an einem Sammelpunkt für das Recycling von elektrischen und elektronischen Geräten abgegeben werden muss ...

Отзывы: