background image

38

Installation

Unpacking

Check that the cooker hood has no damages.
Transportation damages should immediately be
reported to the one responsible for the transport
Damages, faults and eventually missing details
should immediately be reported to the seller.
Take care of the packing material so that small
children cannot play with it.

Placement

The hood is to be mounted on the wall.
When installed, the hood must be not less than 60
cm. above electric burners or 75 cm. above gas or
mixed-fuel burners (fig. 7).

Electrical connection (not for
UK)

Safety warnings for the electrician
Before connecting the appliance to the power
supply, check that the voltage indicated on the
rating plate corresponds to the mains power supply
available.  Appliances fitted with a plug can be
connected to any standard power socket within
easy access.
Should it be necessary to provide a fixed
connection, the hood must only be installed by an
electrician authorised by the local electricity board.
When installing, an omnipolar disconnector with a
distance of at least 3 mm between contacts must
be provided.
Fixed connection of the appliance must only be
carried out by an authorised electrician.

Electrical connection for UK
only

Safety warnings for the electrician
Connect the hood to the mains supply via a double
pole switch which has 3 mm minimum separation
between the contacts.
The switch must be accessible at all times.
The following is valid in the United Kingdom only:
-

the wire which is coloured blue must be
connected to the terminal which is marked with
the letter N or coloured black, -

-

the wire which is coloured brown must be
connected to the terminal which is marked with
the letter L or coloured red.

Min

75 cm

Min

60 cm

Fig. 7

Содержание EFC 640

Страница 1: ...Gebrauchsanweisung Notice d utilisation et d installation EFC6410 6405 9410 9405 650 950 CH1200 900 600 F I D Istruzioni per l uso User manual UK ...

Страница 2: ...chnical assistance service 36 GUARANTEE CONDITIONS 37 Installation 38 Unpacking 38 Placement 38 Electrical connection 38 Wall unit mounting 39 UK Before you use the cooker hood we recommend that you read through the whole user manual giving a direct description of the cooker hood and its functions To avoid the risks that are always present when you use a product driven by electricity it is importa...

Страница 3: ...s used in its filtering function it will operate simply and safely in the above conditions without the need for any of the aforementioned measures When the hood is used in its extractor function the following rules must be followed to obtain optimal operation short and straight outlet hose keep bends in outlet hose to a minimum never install the hoses with an acute angle they must always follow a ...

Страница 4: ...ters are attached to one of the side polystyrene protection panels and should be mounted prior to using the cooker hood in the filter version Extractor version In this version fumes are extracted to the outside via a hose connected to the coupling ring Fig 1 In order to obtain the best performance the hose should have a diameter equal to the outlet hole Fig 1 Filter Version The air is filtered thr...

Страница 5: ...t 15 minutes or until all the odours have disappeared The control switches are located on the unit s front panel Correct ventilation If the cooker hood is to work correctly there must be an under pressure in the kitchen It is important to keep the kitchen windows closed and have a window in an adjacent room open Light switch Motor switch ON OFF Light button OFF Motor button Speed 1 button Speed 2 ...

Страница 6: ...n the dishwasher every four weeks Removing the metal grease filter Push it towards the back of the unit and then pull it down and out Fig 3 Hand washing Soak grease filters for about one hour in hot water with a grease loosening cleaner then rinse off thoroughly with hot water Repeat the process if necessary Refit the grease filters when they are dry Dishwasher Place grease filters in the dishwash...

Страница 7: ...eplacement filters This information is shown on the registration plate located on the inside of the unit The charcoal filter can be ordered from your local ELECTROLUX Service Force Centre Changing the light bulb Disconnect the cooker hood from the main supply Remove the lamp cover Replace the old bulb with a new one of the same type Remount the lamp cover If the light does not come on make sure th...

Страница 8: ...s contact your local Service Force Centre quoting the model and serial number Please note that it will be necessary to provide proof of purchase for any in guarantee service calls In guarantee customers should ensure that the above checks have been made as the engineer will make a charge if the fault is not a mechanical or electrical breakdown Special accessories Charcoal filter KF825 E Nr 942 118...

Страница 9: ... and further information about Service Force please visit the website at www serviceforce co uk Please ensure that you have read the section What to do if as the engineer will make a charge if the fault is not a mechanical or electrical breakdown even the appliance is under warranty Please note that proof of purchase is required for in guarantee service calls Help us to help you Please determine y...

Страница 10: ...ic Costs incurred for calls to put right an appliance which is improperly installed or calls to appliances outside the European Community EC or European Free Trade Area Appliances found to be in use within a commercial environment plus those which are subject to rental agreements Products of Electrolux manufacture which are not marketed by Electrolux European Guarantee If you should move to anothe...

Страница 11: ...lug can be connected to any standard power socket within easy access Should it be necessary to provide a fixed connection the hood must only be installed by an electrician authorised by the local electricity board When installing an omnipolar disconnector with a distance of at least 3 mm between contacts must be provided Fixed connection of the appliance must only be carried out by an authorised e...

Страница 12: ...definitively with 2 4 screws 5X45 7 Fix the chimney support 8 with two screws 5 x 45 mm and two wall dowels on the wall close to the ceiling For exhausting version Fit the connection ring S on the top of the hood with two screws Ø 3 5 x 6 5 mm 9S then fit an axhausting pipe long enough to reach the outside 10S For recycling version Fix definitively the deflector K on the top of the hood with two s...

Страница 13: ...LI1AQB Ed 12 02 ...

Отзывы: