background image

43

Active carbon filter

When the hood is used in recirculation mode an active carbon filter should be used.
Order by the retailer: PNC 942 120 182

Special accessories

Installation

Unpacking

Check that the cooker hood has no damages.
Transportation damages should immediately be
reported to the one responsible for the transport
Damages, faults and eventually missing details
should immediately be reported to the seller.
Take care of the packing material so that small
children cannot play with it.

Placement

The hood is to be mounted on the wall.
When installed, the hood must be not less than 65
cm. above electric burners or 75 cm. above gas or
mixed-fuel burners. (Fig. 3).

Electrical connection

The hood has a power cord with moulded plug
with earth connection to be connected to a wall
outlet of 230 V.
The power outlet should be pre-mounted in such a
way that the power cord is invisible when the hood
is fully mounted.
The power cord length is 1,25 m.

As it is then hard to disconnect the
power plug for cleaning and service,
an easy accessible two pole switch

should be fitted. The switch should conform to
regulations with an opening distance between
contacts of not less than 3 mm.

Min

75 cm

Min

65 cm

Fig. 3

Содержание EFC 639 X

Страница 1: ...Gebrauchsanweisung Libro de Instrucciones Manuel d utilisation EFC 939 X EFC 639 X Istruzioniperl uso UserManual UK F I D E ...

Страница 2: ...ecirculating version 45 For both versions 45 Mounting of carbon filter for recirculating version 45 Using the hood 46 Intensive speed button 46 Control devices for the grease filter and carbon filter 46 Important to know 46 Grease filter saturation led 46 Carbon filter saturation led 47 Correct ventilation 47 Maintenance 47 Grease filter 47 Carbon filter 47 Cleaning 47 Changing the lighting elemen...

Страница 3: ... be connected to flues of other appliances that run on energy sources other than electricity Please keep to the provisions of official direc tives regarding the question of fumes discharge l When the hood is used at the same time of other appliances that run on energy sources other than electricity provision must be made for an adequate supply of air l When installed the hood must be not less than...

Страница 4: ... The hood may be used as follows Exhausting version Recycling version Exhausting version The air is vented outdoors by a 150 mm duct which must be connected to connecting ring with no return valve on top of the motor package The hood cannot be connected to flues of other appliances that run on energy sources other than electricity Please keep to the provisions of official directives regarding the ...

Страница 5: ...ment The hood is to be mounted on the wall When installed the hood must be not less than 65 cm above electric burners or 75 cm above gas or mixed fuel burners Fig 3 Electrical connection The hood has a power cord with moulded plug with earth connection to be connected to a wall outlet of 230 V The power outlet should be pre mounted in such a way that the power cord is invisible when the hood is fu...

Страница 6: ...ig 4 l Drill as indicated on the scheme and fit two dowels two hooks and two screws 5x45 Fig 4 l Hang the hood adjust the position using the screws on the hooks of the hood Fig 5 l Release the grease filters Fig 1 l From the inside of the hood mark on the wall the point corresponding to the hole which will be used to fix definitively the hood Fig 6 l Remove the hood l Drill two hole Ø 8mm and fit ...

Страница 7: ...be on the hood outlet on top of the motor housing and connect it to the wall or roof outlet pipe Recirculating version l If not already fitted fit the connection ring a Fig 7 supplied bajonett attachment turn clockwise and fix with a screw on the deflector b l Insert the deflector in the chimney support and fix it with two screws Fig 7 l Fit a Ø 150 mm exhausting pipe on the motor outlet connectio...

Страница 8: ...n This speed should be used when the concentration of cooking fumes or odours is particularly strong for example when frying cooking fish etc The fast speed will run for about 5 minutes and then return to the speed previously set automati cally 1 2 or 3 or switch off if no speed was selected To turn off the fast speed before the end of the 5 minutes press button A or button B Control devices for t...

Страница 9: ...w the two screws that holds the grease filter and pull the filter down Fig 8 Cleaning To clean the outside of the hood use a cloth mois tened with denatured alcohol or neutral liquid detergents Never use products containing abrasives Carbon filter saturation led The LED marked C indicates carbon filter needs to be replaced This must be done after approximately 160 hours of use Read the instruction...

Страница 10: ...r spare parts you should be ready to give the product number and model denomination This information you will find on the rating label Take away the grease filter and you will find the rating label behind Model Product number Date of purchase Technical data Model EFC 939 X EFC 639 X Capacity Intensive 609 m3 h x 225 m3 h 609 m3 h x 225 m3 h full speed 483 m3 h 483 m3 h low speed 246 m3 h 246 m3 h ...

Страница 11: ......

Страница 12: ......

Страница 13: ......

Страница 14: ...LI1O3A Ed 12 00 ...

Отзывы: