Alarm Codes
Service Code
Family
(Platform specific)
Reason
Type
User visible
User
indication
failure
code read
Action in case of failure happens
Dishwashers before
March 2017
User indication
Please OBSERVE that iBx family has different meaning depending on PBs and PB firmware versions
B0(DIVA2, PB100
before P100R230,
PB200 and PB300)
Turbidity sensor problem
warning
No
Nothing
ib0 (iH0)
Turbidity flag set – cycle continuous
Nothing
B0(PB100 after
P100R230, PB101
and PB150)
Turbidity sensor calibration
unknown error
warning
No
Nothing
ib0 (iH0)
Cycle continues as though the dirt value to be considered is high
Nothing
(PB100 after
P100R230, PB101
and PB150)
lose contact with the turbidity
sensor
warning
No
Nothing
ib1 (iH1)
Cycle continues as though the dirt value to be considered is high
Nothing
(PB100 after
P100R230, PB101
and PB150)
sensor not enough power
calibration
warning
No
Nothing
ib2 (iH2)
Cycle continues as though the dirt value to be considered is high
Nothing
(PB100 after
P100R230, PB101
and PB150)
sensor out of range calibration
warning
No
Nothing
ib3 (iH3)
Cycle continues as though the dirt value to be considered is high
Nothing
(PB100 after
P100R230, PB101
and PB150)
sensor too noisy calibration
warning
No
Nothing
ib4 (iH4)
Cycle continues as though the dirt value to be considered is high
Nothing
C0
No user interface detected
stop
No
Nothing
ic0
Cycle stop and continuous automatic if problem solved
Nothing
Macs – bus communication
stop
Yes
iC1
ic1
Macs low level communication - Cycle stop and continuous automatic
if problem solved
iC0
Adsi – communication to ui
stop
Yes
iC2
ic2
Cycle stop and continuous automatic if problem solved
iC0
Motor control board comm
stop
Yes
iC3
ic3
Command level communication - Cycle stop and continuous
automatic if problem solved
iC0
D0
Tacho problem
warning
No
Nothing
id0
Heating off up to end of cycle – motor to full speed – rta off
Nothing
Tacho critical
warning
No
Nothing
id1
Heating off up to problem is solved – full speed – rta off
Nothing
E0
Flow control positioning
warning
No
Nothing
iE0
Heating element will be switched off
Nothing
F0
Sw fill limit reached
Warning /
fill_limit
No
Nothing
iF0
No further water load up to next drain possible – rta off – cycle
continues up to end of cycle – is power fail saved
Nothing
SW Safety level reached
stop
Yes
iF1
iF1
Cycle stop and continuous automatic if problem solved
iF0
Technical Support – A.R.
Chapter
4
599 79 76 - 53 REV 1.0