7.10 Side panels
After unscrewing the rear attachment
screws (1), the corresponding side wall
can be disengaged by raising it slightly,
and removed.
7.11 Motor area / water channels
Access to the motor area and the water channels is
from the right side.
The condensed water is pumped upwards to the water
receptacle (2) through the red hose (1).
If this is full, it flows over (3) and the water is led into
the float chamber via the transparent hose (4).
The condition is reported to the electronics system via
a micro switch above the float. (See the next page).
1
1
2
2
2
3
4
1