“Built-In Look” Cutout Dimensions

(A) 70

1

/

4

"   (B) 36"   (C) 25"

Standard

Refrigerator Depth

vs. Counter Depth

23

5

/

8

"

Counter Depth

28

1

/

2

"

Standard Depth

26

7

/

8

"

23

5

/

8

"

35

5

/

8

"

69

5

/

16

"

Allow at least 45

1

/

4

" with

doors in 90

°

 open position

29

1

/

2

" to handle

     extension

7

5

/

8

"

68

3

/

16

"

with

3

/

8

"

rollers

Power
cord
location
(right
bottom
rear)

Water
line inlet
location
(left
bottom
rear)

Top View

 24"

Cabinet

25"

Countertop

Recessed
water line

Recessed
electrical outlet

25" Side  Panels, 

1

/

2

" min.  width

Allow 1" min. clearance at rear
for proper air circulation and
water / electrical connections

Counter-Depth Refrigerator Specifications

Product Weight – 300 Lbs.

Voltage Rating – 120V / 60 Hz / 15 or 20 Amps

Connected Load (kW Rating) @ 120 Volts = 1.02 kW
(For use on adequately wired 120V, dedicated circuit having 2-wire
service with a separate ground wire. Appliance must be grounded 
for safe operation.)

Amps @ 120 Volts = 8.5 Amps

Always consult local and national electric & plumbing codes.

When installing next to wall allow 3-1/2" handle clearance.

Floor should be level surface of hard material, capable of supporting fully
loaded refrigerator.

When installing refrigerator adjacent to wall, cabinet or other appliance
that extends beyond front edge of unit, 20" minimum clearance
recommended to allow for optimum 120° to 180° door swing, providing
complete drawer / crisper access and removal. 

(Absolute 4-1/2" minimum

clearance will ONLY allow for 90° door swing which will provide
drawer / crisper access with restricted removal.)

To ensure optimum performance, avoid installing in direct sunlight or
close proximity to range, dishwasher or other heat source.

For proper ventilation, front grille MUST remain unobstructed.

Recess electrical outlet when possible.

Water recess on rear wall recommended to prevent water line damage.

Water Pressure – Cold water line must provide between 30 and 100
pounds per square inch (psi).

Copper tubing with 1/4" O.D. recommended for water supply line 
with length equal to distance from rear of unit to household water supply
line plus 7 additional feet. Optional Water Supply Installation Kits available.

Adjustable front rollers to assist with door alignment.

If optional Collar Kit (PN # ECK23CDS) is to be used, different cutout
dimensions are required. 

(Refer to Collar Kit ECK23CDS Installation

Specifications page on web.)

If optional Louvered Trim Kit (PN # 4480) is to be used, different cutout
dimensions are required. 

(Refer to Louvered Trim Kit 4480 Installation

Specifications page on web.)

“Built-In Look” Specifications

Minimum opening of 70-1/4" H x 36" W x 25" D required to allow for ease
of installation, proper air circulation, and plumbing / electrical connections.

Remove all wall / floor molding prior to installation.

Note: For planning purposes only. Refer to Product Installation Guide 

on the web at electroluxicon.com for detailed instructions.

Optional Accessories

Collar Kit – (PN # ECK23CDS).

Louvered Trim Kit – (PN # 4480).

Note:

Optional Louvered Trim Kit and Collar Kit available

for Counter-Depth Refrigerator. For specifications, refer
to Louvered Trim Kit (4480) Installation page or Collar Kit
(ECK23CDS) Installation page on web.

Содержание E23CS78HPS - Icon s

Страница 1: ...Amps Shipping Weight Approx For detailed Louvered Trim Kit and Collar Kit installation instructions refer to Product Installation Guides on the web at electroluxicon com For use on adequately wired 120V dedicated circuit having 2 wire service with a separate ground wire Appliance must be grounded for safe operation NOTE Always consult local and national electric and plumbing codes Refer to Product...

Страница 2: ...ce that extends beyond front edge of unit 20 minimum clearance recommended to allow for optimum 120 to 180 door swing providing complete drawer crisper access and removal Absolute 4 1 2 minimum clearance will ONLY allow for 90 door swing which will provide drawer crisper access with restricted removal To ensure optimum performance avoid installing in direct sunlight or close proximity to range dis...

Страница 3: ...r detailed instructions Collar Kit ECK23CDS Installation E23CS78HPS E23CS78HSS High standards of quality at Electrolux Home Products Inc mean we are constantly working to improve our products We reserve the right to change specifications or discontinue models without notice Electrolux Major Appliances N A USA 250 Bobby Jones Expressway Augusta GA 30907 1 877 4electrolux 1 877 435 3287 electroluxic...

Страница 4: ... 16 Allow at least 45 1 4 with doors in 90 open position Depth to handle extension 7 5 8 Professional Series 29 1 2 Designer Series 29 3 8 Top View Cabinet Side Panels 3 4 min width 24 Cabinet 25 Countertop Recessed water line Recessed electrical outlet Louvered Trim Kit Counter Depth Refrigerator Optional Louvered Trim Kit 4480 Specifications To use Louvered Trim Kit PN 4480 an enclosure is requi...

Отзывы: