Electrolux E)09C2ASK(W Скачать руководство пользователя страница 22

Air flow direction adjustment

Use SWING to adjust the airflow direction up and down.
1.  When swing is pressed the horizontal louver moves up and down 

automatically.  Press again to stop operation

If the louver oscillates or moves in a position that could affect the cooling or 
heating of the air conditioner the direction of the oscillation/movement would 
alter automatically.

41 electrolux 

how the air conditioner works

Timer operation

1. Press the TIMER button as required. The current timer setting is displayed 

alongside either the TIMER ON or TIMER OFF indicator, and will flash.

2. Press    or    to set the desired time. Each time you push the button, the time 

moves forward or backward by 10 minutes depending on which direction you 
press. The time alters as quickly as you press the button.

3. After setting the timer for TIMER ON and TIMER OFF, check the TIMER 

indicator on the display panel of the indoor unit is illuminated.

4. After the timer has been set, there will be a half a second delay before the 

remote control sends the signal to the air conditioner. Approximately 2 

how the air conditioner works

 electrolux 42

Time

DRY Function

Room

temperature

Set temperature

o

C

o

l

o

C

o

l

o

C

o

l

F

a

o

nl

y

nl

F

an

 o

y

DRY operation

The dry mode will automatically select 
the drying operation based on the 
difference between the set 
temperature and the actual room 
temperature.
The temperature is regulated while 
dehumidifying by repeating turning on 
and off of the cooling operation or fan 
only. The fan speed is LOW.
1.  Push the MODE button to select 

DRY.

2.  Push the TEMP button to set the 

desired temperature from 21ºC to 
28ºC.

3.  Push the ON/OFF button, the 

operation lamp lights and the air 
conditioner start to operate in the 
DRY mode. FAN SPEED is Low. 
Push the ON/OFF button again to 
stop this unit operation.

Due to the difference of the set 
temperature of the unit and the 
actual indoor temperature, the Air 
Conditioner when in DRY mode will 
automatically operate many times 
without running the COOL and FAN 
mode.

SLEEP mode

Press the sleep button to activate the 
sleep mode.  To deactivate, press the 
button again.
Cool only mode:

     • The indoor unit fan operates at a 

low velocity.

     • After and hour of operation, the 

adjusted temperature will increase 
1º C.  After, the unit keeps 
operating 2ºC above the adjusted 
temperature.

In heating mode (some models):

     • The indoor unit fan operates at a 

low velocity.

• After and hour of operation, the 

adjusted temperature will decrease 
1º C.  After, the unit keeps 
operating 2º C below the adjusted 
temperature.

1 °C

1 hour

1 hour

S

e

t

te

m

p

e

ra

tu

re

SLEEP FUNCTION (Cooling mode)

1 °C

1 °C

1 hour

1 hour

SLEEP FUNCTION (Heating mode)

7 hours 

1 °C

S

e

t

 t

e

m

p

e

ra

tu

re

Sleep function is only availaible in the 
Cool/Heat and AUTO mode.

Содержание E)09C2ASK(W

Страница 1: ... this manual completely before operating your room air conditioner 110823P S 351 358 EM_ENGLISH EAS C E 09C2ASK W S M EAS C E 12C2ASK W S M EAS C E 18C2ASK W S M EAS C E 24C2ASK W S M EAS C E 09P5ASK W S M EAS C E 12P5ASK W S M EAS C E 18P5ASK W S M EAS C E 24P5ASK W S M ...

Страница 2: ...trical and electronic devices should be collected separately If you need to dispose of this appliance in the future do NOT throw it away with the rest of your domestic garbage Instead please take the appliance to the nearest WEEE collection point where available The air conditioner you purchased has R410a gas refrigerant a environmental friendly gas which does not damage the ozone layer Environmen...

Страница 3: ... harm or damage The seriousness is classified by the following indications Safety precautions 1 Connect with the power properly Otherwise it may cause electric shock or fire due to excess heat generation 2 Do not modify power cord length or share the outlet with other appliances It may cause electric shock or fire due to heat generation 3 Always ensure effective earthing No earthing may cause elec...

Страница 4: ...e insulation It 05 electrolux safety precautions may cause an electric shock 20 Ventilate the room well when used together with a stove etc An oxygen shortage may occur 21 When the unit is to be cleaned switch off and turn off the circuit breaker Do not clean unit when power is on as it may cause fire and electric shock it may cause an injury 22 Do not put a children pet or house plant where it wi...

Страница 5: ...eforehand 1 Site with machine oil 2 Sites with a high concentration of salinity such as coastal areas 3 Sites with sulfuric gas such as hot water springs 4 Sites with high frequency equipment such as wireless equipment welding machines and medical installations 5 Sites with flammable gases or volatile material 6 Sites with special environmental conditions 7 Laundry rooms Indoor Unit 1 The unit mus...

Страница 6: ...ite cannot have any leakage of flammable gases 6 The site must allow for a piping extension of no less than 5 meters 16 feet and for pipes measuring at least 10 meters 33 feet in length 7 The site must provide enough space around the unit as shown in the diagram 8 Children must not be able to access the installation site More than 60cm More than 30cm More than 200cm More than 30cm More than 60cm 0...

Страница 7: ...n plate above 120mm from the wall above 120mm from the wall Refrigerant pipe hole left Ø 65 Refrigerant pipe hole right Ø 65 45 45 293 90 45 920 A B above 150mm from the ceiling Indoor unit outline Installation plate above 120mm from the wall above 120mm from the wall Refrigerant pipe hole left Ø 65 Refrigerant pipe hole right Ø 65 45 45 305 90 45 850 272 80 489 A abov 15 m from e 0m t c i ing he ...

Страница 8: ...rainage installation Drainage 1 Run the drain hose sloping downward Do not install the drain hose as illustrated below 2 When connecting extension drain hose insulate the connecting part of extension drain hose with a shield pipe do not let the drain hose slack 13 electrolux indoor unit installation Connective pipe installation 1 For the left hand and right hand piping remove the pipe cover from t...

Страница 9: ... the installation place is exposed to strong wind such as a seaside make sure the fan operating properly by putting the unit lengthwise along the wall or using a dust or shield plates 3 Specially in windy area install the unit to prevent the admission of wind If need suspending installation the installation bracket should accord with technique requirement in the installation bracket diagram 4 The ...

Страница 10: ...he distance between the indoor and the outdoor unit C Cut the pipes a little longer than the measured distance D Cut the cable 1 5m longer than the pipe length 2 Burr removal A Completely remove all burrs from the cut cross section of pipe tube B Put the end of the copper tube pipe in a downward direction as you remove burrs in order to avoid dropping burrs into the tubing 3 Putting nut on A Remov...

Страница 11: ...10 of rated voltage 3 The creepage protector and main power switch with a 1 5 times capacity of Max Current of the unit should be installed in power circuit 4 Ensure the air conditioner is grounded well 5 According to the attached Electrical Connection Diagram located on the panel of the outdoor unit to connect the wire 6 All wiring must comply with local and national electrical codes and be insta...

Страница 12: ...electrical components Secure the cable onto the control board with the cord clamp Connect the cable to the indoor unit Electrical box cover 21 electrolux electrical work electrical work electrolux 22 40mm 40mm 10mm 10mm 18000 btu s Cool model CABLE 18000 btu s Heat Cool model CABLE Cable code 18000 btu s Heat Cool model CABLE 40mm 10mm 40mm 10mm Cable A Cable C Cable B or Cable code Cable code Cab...

Страница 13: ...crew Cover 40mm 40mm 10mm 10mm 18000 btu s Cool model CABLE 18000 btu s Heat Cool model CABLE Código del cable 18000 btu s Heat Cool model CABLE 40mm 10mm 40mm 10mm Cable D Cable F Cable E or Cable code Cable code Cable code 24 COOL MODEL 000 Btu s MODELS 24000 Btu s 24000 Btu s HEAT COOL MODEL or or or or or or Connector A Connector A Connector A Connector C Connector B Connector B Connector D Ca...

Страница 14: ...ffects as indicated below 1 Pressure in the system rises 2 Operating current rises 3 Cooling or heating efficiency drops 4 Moisture in the refrigerant circuit may freeze and block capillary tubing 5 Water may lead to corrosion of parts in the refrigeration system 6 Therefore the indoor unit and tubing between the indoor and outdoor unit must be leak tested and evacuated to remove any noncondensabl...

Страница 15: ...e hose Manifold valve 76cm Hg Charge hose Handle Lo Handle Hi Outdoor unit Indoor unit 8 Fully open the packed valve stems B and A 9 Securely tighten the cap of the packed valve 27 electrolux electrical work Electrical safety Perform the electric safe check after completing installation Gas leak check Soap water method Apply a soap water or a liquid neutral detergent on the indoor unit connection ...

Страница 16: ... use for a long period of time it is recommended that the air filter be cleaned before use During continuous use clean the air filter every two weeks 5 This air conditioner was designed for use under the following conditions If air conditioner is used outside of the above conditions certain safety protection features may come into operation and cause the unit to function abnormally Room relative h...

Страница 17: ...when select TURBO function on cooling operation or on heating operation available for the type adopts PTC in the indoor unit only DIGITAL DISPLAY Displays the current setting temperature when the air conditioner is in operation AUTO Displayed during Auto operation TIMER Displayed during Timer operation CLEAN AIR optional Displayed when CLEAN AIR feature is activated Signal receptor 13 16 17 18 19 ...

Страница 18: ... in the compartment indicated in the drawing located inside the compartment 3 Slide in the cover 4 If the remote control is not operated for long period of times batteries should be discarded Remote control instructions 1 The signal reach distance of the remote control to the receiver that is inside the main unit of the air conditioner is 8 meters Any obstruction placed between the receiver and th...

Страница 19: ... the signal during any 7 minute interval 1 2 3 4 5 Remote control description 35 electrolux remote control description DIRECTION Press this button to change the swing angle of the louver The swing angle of the louver is 6o for each press When the louver swing at a certain angle which would affect the cooling and heating effect of the air conditioner it would automatically change the swing directio...

Страница 20: ...indoor unit MODE Displays the current operation mode Including AUTO COOL DRY HEAT FAN ONLY and back to AUTO Note Not applicable to cooling only models ON OFF Displayed by pressing the ON OFF button Press the ON OFF button again to remove TIMER Indicate Timer on off time 0 23 50 hours or clock time The clock time is indicated only when no AUTO ON OFF timer is set When AUTOTIMER feature is operating...

Страница 21: ...Air Conditioner is ready for use switch on the power and the OPERATION indicator lamp on the display panel of the indoor unit starts flashing 1 Use the MODE select button to select AUTO 2 Push the TEMP button to set the desired room temperature The most comfortable temperature setting are between 21ºC o to 28ºC 3 Push the ON OFF button to start the air conditioner The OPERATION lamp on the display...

Страница 22: ...lect the drying operation based on the difference between the set temperature and the actual room temperature The temperature is regulated while dehumidifying by repeating turning on and off of the cooling operation or fan only The fan speed is LOW 1 Push the MODE button to select DRY 2 Push the TEMP button to set the desired temperature from 21ºC to 28ºC 3 Push the ON OFF button the operation lam...

Страница 23: ...e reduced and the air conditioner may stop running 6 Clean the air filter periodically otherwise cooling or heating performance may be reduced 7 Do not operate unit with horizontal louvre in closed position 43 electrolux how the air conditioner works How to use the indoor unit Adjusting air flow direction Adjust the air flow direction properly otherwise it might cause discomfort or cause uneven ro...

Страница 24: ...oo small as COOLING or HEATING performance may be impaired due to too restricted air flow area Do not operate unit with horizontal louver in closed position When the air conditioner is connected to power initial power the horizontal louver may generate a sound for 10 seconds this is a normal operation 45 electrolux how to use the indoor unit Manual operation without remote control Manual operation...

Страница 25: ...once a month and replace every 4 to 5 months Use a vacuum cleaner filtro de aire filtro de aire 47 electrolux maintenance then dry 6 Clean the support frame using a vacuum cleaner or water After dry for a couple of hours or until dry 7 Insert the fresh air filter in its original place 8 Insert the high part of the air filter fresh air filter Support frame again in the unit keeping in mind that the...

Страница 26: ...normal condition when the air conditioner has not been used for a long time or during first use of the unit 49 electrolux operation tips A peculiar smell comes out from the indoor unit This is caused by the indoor unit giving off smells permeated from building material from furniture or smoke The air conditioner turns to FAN only mode from COOL or HEAT For cooling and heating models only mode When...

Страница 27: ...s not stop by disconnecting and connecting the unit 2 Frequent change of fuses and malfunctions in the switch circuit 3 Water spills over the equipment 4 Remote control does not work 5 Any other abnormal situation If your air conditioner malfunctions check the following information to find solutions or probable causes of the failure Do not try to repair the unit by yourself if these solutions do n...

Страница 28: ...mm Indoor unit net weight kg Outdoor unit width mm Outdoor unit high mm Outdoor unit depth mm Outdoor unit net weight kg W S M Heat Cool 9000 9000 220 50 790 275 196 8 685 430 260 22 EASC09P5ASK EASE09P5ASK W S M Heat Cool 12000 12000 220 50 790 275 196 9 700 540 240 24 5 EASC12P5ASK EASE12P5ASK W S M Heat Cool 18000 18000 220 50 930 275 198 10 780 540 250 33 EASC18P5ASK EASE18P5ASK W S M Heat Coo...

Отзывы: