SOI/TD 2004-11 PR
19/26
599 36 44-44
11 USER MODE
With this procedure it is possible to:
•
Modify the regeneration level selection (depending on the water hardness).
•
Activate or deactivate the rinse-aid supply.
11.1 Regeneration selection
To activate the function:
1. Press and hold down button
S1
.
2. Turn the knob to
Position 1
:
The LEDs LD0 and LD1 flash
Release
button
S1
3. Press
button
S1
The regeneration level is displayed by the
End of cycle
LED which flashes and pauses at intervals: for the
decodification, see summary table of alarms.
Press button
S1
to increase the regeneration level
according to the following values:
No. of flashes of
“End of cycle” LED
Water fill between
regeneration
procedures
Time
regeneration
solenoid opens
Position of
tank
selector
Hardness of water
treated
Level
nº
Litres
sec
nº
º F (TH) º D (dH)
1
1
- - -
0
1
0 > 7
0 > 4
2
2
130
240
1
8 > 18
4 > 10
3
3
94
240
1
19 > 25
11 > 14
4
4
70
240
1
26 > 32
15 > 18
* 5
5
53
240
2
33 > 39
19 > 22
6
6
37
240
2
40 > 50
23 > 28
7
7
20
240
2
51 > 64
29 > 36
8
8
15
240
2
65 > 75
37 > 42
9
9
10
240
2
76 > 90
43 > 50
10
10
3
2x240
2
91 > 125 51 > 70
* “5” =
Level set by factory Position of tank
selector:
“2”