![Electrolux CZC16/9FA Скачать руководство пользователя страница 17](http://html.mh-extra.com/html/electrolux/czc16-9fa/czc16-9fa_service-manual_98738017.webp)
NOFROST REFRIGERATORS WITH EXTERNAL ELECTRIC WIRING
17/25
6.3 FREEZER COMPARTMENT :
- fan
D
;
- thermal overload cut-outs
E
(for technical data see
Tab. A
);
- evaporator battery
F
;
- defrosting heater
G
(for technical data see
Tab. B
).
Tab. A
Tab. B
pnc Refrigerating
gas
Voltage Resistance Power
Notes
925886xxx R134a 240
V
242
Ω
238
W
-
925886xxx R600a 240
V 213
Ω
(see notes)
271 W
Total value of the 2 resistances
925887xxx R134a 240
V
220
Ω
262
W
-
925887xxx R600a 240
V 207
Ω
(see notes)
278 W
Total value of the 2 resistances
925888xxx R134a 240
V
220
Ω
262
W
-
925888xxx R600a 240
V 207
Ω
(see notes)
278 W
Total value of the 2 resistances
OPERATING TEMPERATURE
TYPE OF THERMAL
OVERLOAD CUT-OUT
OPENING CLOSURE
DEFROSTING
+ 8 °C
- 1 °C
SAFETY
+ 40 °C
+ 30 °C