- 11 -
DGS-TDS-N 12.08 U. H. / A. B. © Electrolux
599 714 137
EN
5.
Failure detection
Detected
failure
Possible Failure
Solution
Displayes keeps
dark
Power supply incorrect
Check supply voltages of all
phases; Check mainsterminal
if connected right
LED check
after reset of
mains
Distance between interface
and glass is too large
Exchange interface with
silicone carrier
Interface is defect
Change interface
No displays
after reset of
mains
No 5 Voltage on the bus
1. Check wirings
2. Exchange
powerboard
(left)
Demo mode is active
Remove demo mode in the
service menue
Relay for heater is defect
Check if a click of the relay is
to hear if not the power board
is defect
Radiant heater
is not working
Heater is defect
Check the resistance of the
heater with a multimeter. The
resistance need to be lower
than 100Ohm
If it is higher exchange heater
More than one
heater is not
working
Phase is missing,
Connection is not right
Check voltage on mains
connection; Check cable
connection in the main
terminal