Page 18
ELECTRONIC SURFACE ELEMENT CONTROL (ESEC 30) TROUBLESHOOTING GUIDE
- Wave Touch Models-
When a failure occurs in the ESEC system the control
will beep and usually display an error code. These error
codes will appear in two front element displays. The left
side will display the letter E and the right side will display
the error code number. (Fig 1). In some cases the control
may beep and display only the letter “ E “ in the left
display or there may be no display in either window.
ERROR CODES Wave Touch Models
Fig 1
The troubleshooting guide below provides a listing of the likely failure condition or cause, as well as
suggested corrective actions to be taken. Perform the steps one at a time in the order listed below to
correct the specific failure condition.
The ESEC 30 Electronic Surface Element Control System operates the radiant surface elements and
warming zone element. The ESEC 30 UIB receives the operator selection from the TST panel and
signals the ESEC 20 Surface Unit Control Board (relay board) which then closes the appropriate relay
to turn on the desired element.
If a failure occurs in the ESEC system there are several error codes that may be displayed to guide
the service technician in diagnosing the failure.
It is important to note that the error codes are displayed are differently between the “A” models with
Wave-Touch™” display and the “B” model with “ IQ Touch™” display. Although the display method is
different the potential failure conditions and possible cause are the same.
ELECTRONIC SURFACE ELEMENT CONTROL SySTEM (ESEC 30)
SyMPTOM
LIKELy FAILURE
CONDITION/CAUSE
SUGGESTED CORRECTIVE ACTION
Control Beeping
No Error Codes
Displayed
ESEC key display ribbon
cable is disconnected or
defective
1. Check/reseat ribbon connection J3 connection on the ESEC 30 UIB.
2. Replace ESEC 30 UIB.
3. Replace TST panel.
“ E “
In Displays
ESEC key display ribbon
cable is disconnected or
defective
1. Check/reseat ribbon connection J2 connection on the ESEC30 UIB.
2. Replace ESEC 30 UIB.
3. Replace TST panel.
“E 11”
In Displays
Shorted Keypad
1. Reset power supply to range to see if failure code will clear.
2 Check/reseat ribbon harness and connectors between the TST panel and ESEC 30 UIB.
3. Replace the TST panel
4. Replace the ESEC 30 UIB
“ E 14 “
In Displays
ESEC key read ribbon
cable is disconnected or
defective
1. Check/reseat ribbon connection J4 connection on the ESEC 30 UIB.
2. Replace ESEC 30 UIB.
3. Replace TST panel.
“ E 15 “
In Displays
Signal loss between ESEC
30 UIB and ESEC relay
board.
1. Check/reseat harness and connections between connector P6 of ESEC30 UIB to connector J2 of
ESEC relay board. Repair or replace harness as needed.
2. If connection and harness are good, then replace ESEC relay board.
3. If error remains ESEC30 UIB.
4. If the previous steps do not resolve the failure replace the TST panel.
Содержание CEI30EF5GB
Страница 11: ...Page 11 Wiring Diagram Electric Wave Touch Models with Lower Oven ...
Страница 12: ...Page 12 Schematic Diagram Electric WaveTouch Models with Lower Oven ...
Страница 13: ...Page 13 Wiring Diagram Electric IQ Touch Models with Warming Drawer ...
Страница 14: ...Page 14 Schematic Diagram Electric IQ Touch Models with Warming Drawer ...
Страница 46: ...Page 46 ...