background image

 

INTRODUCTION AND WARNINGS

 

1

 

INTRODUCTION

 

This manual is a guide to the efficient use of the machine and also contains practical information concerning the
functioning, adjustments and user maintenance of your new scrubber/drier. Your machine has been designed and
constructed to ensure maximum performarnce and ease of operation in a wide variety of applications. Before delivery, the
machine has been tested in our factory and by our distributor to ensure that it is delivered to you in perfect condition.  To
maintain the machine in this condition and guarantee functioning without problems, it is essential that the periodic
maintenance operations indicated in this manual are properly carried out. Before using the machine, carefully read this
manual and keep it within easy reach for your future reference. Indications of “LEFT” and “RIGHT” are as seen from the
operator position. If you should need any further information concerning the machine, please do not hesitate to contact
either Electrolux Euroclean or our local distributor. 

 

MODIFICATIONS AND IMPROVEMENTS

 

Electrolux Euroclean aim toward continuous improvement of its machines and reserves the right to carry out modifications 
and improvements whenever necessary without being obliged to update machines which have been sold previously.

 

SAFETY
You too can avoid accidents.

 

No accident prevention programme is effective without the total co-operation of the person directly responsible for the 
functioning of the machine. The majority of accidents which may occur either during work or transferring the machine from 
site to site are caused by the non-observance of the most elementary safety rules. An alert and cautious operator is the best 
guarantee against accidents and is more effective than any other part of an accident prevention programme.

The machine must be switched off and disconnected from either its battery or mains supply before any servicing or 
adjustment of operational parts be carried out. Ensure that any assistant is clear of the machine and that covers are closed 
before switching on.

 

GENERAL SAFETY RULES

 

The rules below have to be followed carefully in order to 
avoid damages to the operator and to the machine.

- Read the labels carefully on the machine; Do not cover 

them for any reason and replace them immediately if 
damaged.

- The socket for the power supply must be fitted with a 

standard earthing (ground) system.

- With the brushes in working position, avoid touching or 

passing over the mains cable. Avoid damaging by 
squashing, bending or stressing.

- Where there is damage to the mains cable, stop the 

machine, take off the plug from the mains system, and 
replace the damaged cable immediately by calling the 
Electrolux Service department.

- Do not mix different detergents, avoiding harmful odours.
- Do not place any liquid containers onto the machine.
- The storage temperature has to be b15°C and + 

55°C.

- The perfect operating temperature should be between 0° 

C and 40° C.

- The humidity should be between 30 and 95%.
- Do not use the machine in explosive atmosphere.
- Do not use the machine as a means of transport.
- Do not use acid solutions which could damage the 

machine.

- Avoid working with the brushes when the machine stands 

still, in order to prevent floor damages.

- Do not vacuum iflammable liquids.
- In case of fire, use a powder extinguisher. Do not use 

water.

- Do not strike shelvings or scaffoldings, where there is 

danger of falling objects.

- Adapt the utilization speed to the adhesion conditions.
- Do not exceed over the limit gradient stated, to avoid 

conditions of instability (2% max).

- The machine has to carry out simultaneously the 

operations of washing and drying. Different operations 
have to be carried out in areas which are not permitted 
for the passage of non employed staff. Signal the areas 
of moist floors with suitable signs.

- If the machine does not work properly, check by 

conducting simple maintenance procedures. Otherwise, 
it is better to ask for technical service.

-Where parts are required, ask for ORIGINAL spare parts 

to an agent and/or to an authorized dealer.

- For any maintenance operation take off the power supply 

from the machine.

- Do not take off the pieces which require the use of tools 

to be removed.

- Do not wash the machine with direct water jets or with 

high water pressure not with corrosive material.

- Every 200 working hours have a machine check through 

a service department.

- The machine should not be abandoned, because of the 

presence of toxic-harmful materials (batteries, oil etc.). 
This disposal must be subject to the rules which provide 
for its scrapping in appropiate centres.

- The machine does not cause any harmful vibrations.

 

24

 

SAFETY FEATURES

 

For all models:

Safety micro switch:

 

Micro switch to shut off all the functions when the 
tank unit is in the upright position. (SEMKO 
APPROVAL).

Содержание AW 445

Страница 1: ... 475 Graphic project VISUAL DIVISION Milan Italy Operating instruction MANUAL Nilfisk Advance Italia S p A Località Novella Terza 26862 Guardamiglio Lodi Italia Tel 39 0377 451124 Fax 39 0377 51443 S31E47UKIN 1 99 01 S31E47UKIN 1 99 01 ...

Страница 2: ...OR 306 OVERTEMPERATURE ON THE POWER ELECTRONIC BOARD AUTOMATIC STOP OF ALL THE FUNCTIONS OF THE MACHINE TURN OFF THE KEY AND WAIT FOR THE SELF COOLING OF THE ELECTRONIC BOARD AT LEAST 20 MINUTES THEN CHECK THAT THE ROTATION OF THE DRIVE MOTOR AND OR OF THE BRUSH MOTOR S IS FREE IT COULD BE USEFULL TO REDUCE THE PRESSURE OF THE BRUSH ES ON THE FLOOR IF THE 306 CODE OCCURS FREQUENTLY CALL THE SERVIC...

Страница 3: ...mediately if damaged The socket for the power supply must be fitted with a standard earthing ground system With the brushes in working position avoid touching or passing over the mains cable Avoid damaging by squashing bending or stressing Where there is damage to the mains cable stop the machine take off the plug from the mains system and replace the damaged cable immediately by calling the Elect...

Страница 4: ...nsform the machine from mains version to battery operated version Mains unit or transformer to change the machine from the battery operated version to the mains version For all versions of models AW445 AW445 T and AW455 T A kit is available to equip the machine with the membrane in this case also the water pump must be mounted For all models A front splash guard is also available For all models In...

Страница 5: ...FF Click ON yes yes yes yes Electrovalves nr 3 hole diameters 3 5 4 5 5 5mm nr 3 hole diameters 3 5 4 5 5 5mm nr 3 hole diameters 3 5 4 5 5 5mm nr 3 hole diameters 3 5 4 5 5 5mm Water pump optional 12V 31W 0 9lt 1 12V 31W 0 9lt 1 12V 126W 9lt 1 12V 126W 9lt 1 Water flow lt min 1 3 2 6 1 3 2 6 1 3 2 6 1 3 2 6 Water flow pump lt min opt 1 9 3 1 9 3 2 8 4 5 2 8 4 5 Max slope 2 2 Driving speed F R Km ...

Страница 6: ...ves nr 3 hole diameters 3 5 4 5 5 5mm nr 3 hole diameters 3 5 4 5 5 5mm Water pump optional 12V 126W 9lt 1 12V 126W 9lt 1 Water flow lt min 1 3 2 6 1 3 2 6 Water flow pump lt min opt 2 8 4 5 2 8 4 5 Driving speed F R Km h nr 2 max 4 5 nr 2 max 2 5 nr 2 max 4 5 nr 2 max 2 5 Parking brake yes yes Working width mm 538 538 Max slope 16 16 Squeegee width mm 800 800 Solution tank capacity lt with membra...

Страница 7: ...x320mm nr 2x370mm Brush speed scrubbing 270 RPM 180 RPM Brush pressure to floor Kg from 21 to 36 from 30 to 45 Automatic Click OFF Click ON yes yes Electrovalves nr 3 hole diameters 3 5 4 5 5 5mm nr 3 hole diameters 3 5 4 5 5 5mm Water pump 12V 126W 9lt 1 12V 126W 9lt 1 Water flow pump OFF lt min 1 3 2 6 1 3 2 6 Water flow pump ON lt min 2 8 4 5 2 8 4 5 Driving speed F R Km h nr 2 max 5 0 nr 2 max...

Страница 8: ... lifting lowering and brush motor switch on off 26 Squeegee 2 3 10 9 5 6 7 8 24 25 12 26 19 BEFORE ANY MAINTENANCE IS CARRIED OUT THE BATTERY MUST BE UNPLUGGED OR THE MAINS LEAD UNPLUGGED Periodically remove the filter inside the scrubbing detergent tank scrub it with a stiff brush under running water to remove any accumulated foreign matter Note The filter is mounted by simply pressing it toward ...

Страница 9: ...of the machine pull the machine that is not equipped with the drive motor Clean carefully the three pins of each brush to keep efficient the Click ON Click OFF function To mount the new brushes see the Preparation for use at page 10 CLEANING OR REPLACING THE BRUSHES ON OFF A PREPARATION FOR USE Partially unscrew the two middle levers on the squeegee Push the squeegee into the locating lugs as illu...

Страница 10: ...tion then fit the batteries and connect the supplied links as indicated When the battery set has been properly charged plug the battery socket into the machine as shown Lower the tank unit to safely cover exposed working parts 17 Remove the cap from the hose unscrewing the knob and empty the tank There is a water level sensor also in the tank for the clean water A When the tank is going to be empt...

Страница 11: ...about battery maintenance see also the relevant paragraph 16 Also the tilting of the squeegee can be adjusted by means of the dedicated knob in order to improve the drying capability of the machine Move the machine slowly forward and adjust the squeegee pressure and tilting controls until the lips bend over evenly as illustrated below The lips must be replaced when they become feather edged or tor...

Страница 12: ...rmal operation all the functions will restart automatically AUTOPOWER ON NOTE for all versions of model AW445 and brush driven model the rotation of the brush will make the forward displacement of the machine easyer On the same model the AUTOPOWER OFF AUTOPOWER ON function is not available The following adjustments can be done on the machine increase or reduction of the pressure of the brushes on ...

Страница 13: ... far as it will go The brush motors will start automatically the indicator will light and the motors will engage the brushes PREPARATION FOR USE 14 ON OFF In order to achieve a further reduction of the water flow the water pump can also be switched off by means of push button C The same button allows to re switch on the water pump NOTE on all versions of model AW445 without traction the push butto...

Страница 14: ... by means of switch B Switch the machine on by turning the key in the master key switch a quarter turn clockwise Lower the brushes by pushing the relevant pedal to the right to unlatch it and bring it to the upper position the brush motors the electrovalves and the water pump will start automatically in a few seconds The relevant green light indicators will turn on on the control panel To increase...

Отзывы: