Install a disconnecting switch with a capacity at
least equal to that given in the technical data table,
a 30mA residual current circuit breaker and an
overcurrent device (magnetothermal cut-out with
manual reset or fuse) between the appliance and
the mains power outlet.
RATING PLATE
The rating plate contains identification and technical
data and is located on the right-hand side panel of the
appliance (Figure 5).
Figure 5
B1
WATER CONNECTION
• Position the dishwasher and level the appliance by
turning
the
relative
height-adjustable
feet
(Figure 5).
• Connect the appliance water supply pipe “A”
(Figure 4) to the mains, fitting a cut-off cock, the fil-
ter provided and a pressure gauge between the
appliance and the mains (Figure 6).
• In models with incorporated water softener, connect
the double non-return valve "B" (Figure 6) supplied
and the machine supply pipe.
Figure 6
• Check that the
dynamic
water supply
pressure
,
measured between the appliance and the main, is
between 200 and 300 kPa
for machines with pres-
sure boiler and
between 50 and 700 kPa
for
machines with atmospheric boiler (test while dish-
washer tank or boiler is filling with water).
If the
pressure is too high, fit a suitable pressure
reducer on the inlet pipe.
- On the model with free-fall drainage:
connect the waste outlet pipe “C” (Figure 4) to the
main drain pipe, fitting a trap, or place the outlet pipe
over an “S” trap set into the floor.
- On the model with drain pump:
position the outlet pipe at a height anywhere between
750 and 1000 mm from the floor.
Check that about 4 litres of water flow out of the outlet
pipe during the rinse cycle.
B2
ELECTRICAL CONNECTION
Figure 7
• Before carrying out the electrical connection, check
that the voltage and frequency on the appliance
rating plate correspond to those of the mains
electricity supply.
• The earth wire at the terminal end must be longer
(max. 20 mm) than the phase wires.
• Connect the earth wire of the power supply cable to
an efficient earth clamp. The appliance must also
be included in a unipotential system, the connec-
tion being made through the screw “Q” (Figure 4)
marked with the symbol “ ”. The unipotential wire
must have a cross section of 10 mm
2
.
Power
supply
400…415V
3N
(standard
configuration)
Figure 8
B INSTRUCTIONS FOR THE INSTALLER/MAINTENANCE PERSON
Model LS6
PNC 9CGX 502003 05 Ser.N .123000001
AC 400V 3N 50Hz
Power Boiler 16500w
Power Tank 7500w
Power Max 26800w
Made in EEC
Model RT10 ED
PNC 9CGX502003 05
Ser.N .123000001
!
B
CAUTION
THE EARTH AND ELECTRICAL CON-
NECTIONS SHOULD BE IN COMPLI-
ANCE WITH NATIONAL REGULATIONS.
AC