L.2
Alarms
A1
NO WATER
• Check that the tap is open.
• Check that the water inlet filter is clean.
• Check the minimum mains pressure.
• Check that the overflow pipe is inserted (only for appliances
without drain pump).
B1
INEFFICIENT DRAINAGE
• Check if the overflow has been removed.
• Check for obstruction on the waste outlet pipe and the
overflow aperture.
B2
TANK WATER LEVEL TOO HIGH
• Check for obstruction on the waste outlet pipe and the
overflow aperture.
C1 – C8
CALL THE SERVICE CENTRE
E1 – E8
CALL THE SERVICE CENTRE
• The appliance continues to operate, but appropriate checks
by a technician are recommended.
F21 – F22
1
CALL THE SERVICE CENTRE
• Resin regeneration cycles are not performed. The appliance
continues to operate without water softener.
1.
Only for appliances with incorporated continuous water softener.