Page 20 DWSI1021
REPAIR TECHNIQUES COMPONENTS AND RESISTANCE VALUES
COMPONENTS
C
T
NOTES
ON / OFF SWITCH
0 Ω on component
0 Ω on component
ON/OFF button is
pressed
DOOR SWITCH
CN2.9 -
CN2.2 0 Ω
KN2.8 -
KN2.10 0 Ω
Door is close
PRESSURE
SWITCH
CN2.10 -
CN2.2
0 Ω
∞Ω
KN2.9 - KN2.10
0 Ω
∞Ω
Full fill water no water
DRAIN PUMP /
HANYU
CN2.2 -
CN2.4 220 Ω % ±10
KN2.4 -
KN2.10 220 Ω % ±10
DRAIN PUMP /
LEILI
CN2.2 -
CN2.4 141 Ω % ±10
KN2.4 -
KN2.10 141 Ω % ±10
WATER INLET
VALVE
CN2.6 -
CN2.9 4200 Ω ± %10
(20°C)
KN2.6 -
KN2.8 4200 Ω ± %10 (20°C)
REGENERATION
VALVE
CN2.2 -
CN2.7 3560 Ω ±
%10(25°C)
KN2.2 - KN2.10
3560 Ω ± %10(25°C)
SALT SENSOR
CN5.1 -
CN5.2
0 Ω NO SALT
∞Ω THERE IS
KN50.10 - KN
50.11
0 Ω NO SALT
∞Ω THERE IS SALT
Measure just on the
electronic
HEATER
29.1 ± 1,5 Ω
29.1 ± 1,5 Ω
Measure just on the
component
DETERGENT
DISPENSER
2300 Ω ±%10 (25 C°)
2300 Ω ±%10 (25 C°)
Measure just on the
component
CIRCULATION
PUMP
CN2.3 - CN2.9
KN2.3 - KN 2.8
Primary winding
Secondary winding
(from the component)
SET NTC SENSOR
CN 3.2
CN 3.1
KN 50.1
KN 50.2
FAN MOTOR
CN 6.2 - CN 2.9
KN 6.2 - KN 2.8
DIVERTER
CN 6.1 -
CN 2.9 10500 ± %7 Ω
KN 6.1 -
KN 2.8 10500 ± %7 Ω
RINSE AID
SENSOR
CN 5.3 - CN
5.2
0 Ω NO RİNSE
AİD
∞Ω THERE IS
RİNSE
KN 50.8 - KN
50.9
0 Ω NO RİNSE AİD
∞Ω THERE IS
RİNSE AİD
Rinse aid off Rinse
aid on
FLOATER
(MICROSWITCH)
CN2.1 - CN
2.5 CN2.1 -
CN 2.4
0 Ω
∞Ω
KN2.5 - KN 2.10
KN2.4 - KN 2.5
0 Ω
∞Ω
Microswitch is
inactive (no water).
Micro-switch is active
(there is water)