grounding plug, the plug
MUST
be plugged into an
appropriate, copper wired receptacle that is properly
installed and grounded in accordance with all local
codes and ordinances or in the absence of local codes,
with the National Electrical Codes, ANSI/NFPA 70
(latest edition). If in doubt, call a licensed electrician.
DO NOT
cut off or alter the grounding prong on the
power supply cord. In situations where a two-slot
receptacle is present, it is the owner’s responsibility
to have a licensed electrician replace it with a
properly
grounded
three prong grounding type receptacle.
WATER SUPPLY REQUIREMENTS
Hot and cold water faucets
MUST
be installed within 42
inches (107 cm) of your washer’s water inlet. The faucets
MUST
be 3/4 inch (1.9 cm) garden hose type so inlet
hoses can be connected. Water pressure
MUST
be
between 30 and 120 pounds per square inch (maximum
unbalance pressure, hot vs. cold, 10 psi.) Your water
department can advise you of your water pressure. The
hot water temperature should be about 140 degrees F
(60 degrees C).
DRAIN REQUIREMENTS
1. Drain capable of eliminating 17 gals (64.3 L) per
minute.
2. A standpipe diameter of 1-1/4 in. (3.18 cm) minimum.
3. The standpipe height above the floor should be:
Minimum height: 24 in. (61 cm)
Maximum height: 96 in. (244 cm)
NOTE:
Drain hose attached to the washer can reach a 90 in.
(229 cm) high standpipe. For higher standpipe, use hose
P/N 134369410, available from an authorized parts
distributor.
BACK
96 in.
(244 cm)
Max
24 in
(61 cm)
Min